Posterior corneal curvature after penetrating keratoplasty with and without sutures

被引:8
作者
Seitz, B [1 ]
Langenbucher, A [1 ]
Beyer, A [1 ]
Kus, MM [1 ]
Behrens, A [1 ]
机构
[1] Univ Erlangen Nurnberg, Augenklin & Polklin, D-91054 Erlangen, Germany
关键词
posterior corneal curvature; posterior power; posterior astigmatism; posterior asphericity; penetrating keratoplasty; double running suture; suture removal;
D O I
10.1055/s-2000-10336
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: After penetrating keratoplasty (PK), peripheral swelling effects, malapposition of the graft in the recipient bed and suture tension may result in a changed ratio of curvature between anterior and posterior corneal surface. The purpose of this pilot study was to assess the posterior corneal curvature after PK with and without sutures and to compare this data to the posterior curvature of normal individuals. Patients and Methods: In this cross-sectional study, 44 eyes after PK with a double running 16-bite diagonal antitorque suture in place (mean age 37+/-14 years,:spherical equivalent (SEQ) -0.1+/-3.2 diopters (D)), 36 eyes with "all-sutures-out" (mean age 40+/-18 years, SEQ -0.8+/-3.5 D), and 464 normal control eyes (mean age 34+/-16 years, SEQ -0.3+/-2.2 D) were included. Based on Orbscan(R) slit scanning topography analysis the following parameters were assessed: posterior power, posterior astigmatism, and posterior asphericity in various segments. Results: With sutures in place the posterior central power ranged from -7.36 to -4.53 (mean -5.90+/-0.62) D, astigmatism ranged from 0.13 to 1.15 (mean 0.42+/-0.20) D, and asphericity ranged from 0.20 to 2.97 (mean 1.13+/-0.76, 56% oblate). With "all-sutures-out" the central power ranged from -7.56 to -4.93 (mean -6.41+/-0.53) D, astigmatism ranged from 0.13 to 1.15 (mean 0.39+/-0.19) D, and asphericity ranged from 0.26 to 3.04 (mean 1.25+/-0.76, 44% oblate). In the control group the central power ranged from -7.20 to -4.90 (mean -6.01+/-0.29) D, astigmatism ranged from 0.01 to 1.04 (mean 0.12+/-0.10) D, and asphericity ranged from 0.33 to 3.13 (mean 1.06+/-0.37, 47% oblate). Mean negative posterior power in grafts with "all-sutures-out" was significantly greater than in grafts with "all-sutures-in" and normal controls (p<0.001), but showed no difference between the two latter groups (p=0.56). Posterior astigmatism did not differ significantly comparing grafts with and without sutures (p=0.44). However, astigmatism was significantly higher in grafts than in the control group (p<0.0001). Asphericity did not differ significantly comparing grafts with and without sutures (p=0.49) or comparing grafts to controls (p>0.38). Conclusions: Except for the amount of astigmatism, the posterior corneal curvature of grafts with a double running suture in place does not seem to differ significantly from that of normal corneas. The removal of a double running suture tends to steepen the central posterior curvature. Knowledge about the individual posterior corneal curvature may have a favorable impact on the precision of intraocular lens power calculation for cataract surgery in eyes after PK.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
[31]   Corneal endothelial cell changes twenty years after penetrating keratoplasty [J].
Inoue, K ;
Kimura, C ;
Amano, S ;
Oshika, T ;
Tsuru, T .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (02) :189-192
[32]   Corneal Sensitivity in Keratoconus after Penetrating and Deep Anterior Lamellar Keratoplasty [J].
Ceccuzzi, R. ;
Zanardi, A. ;
Fiorentino, A. ;
Tinelli, C. ;
Bianchi, E. .
OPHTHALMOLOGICA, 2010, 224 (04) :247-250
[33]   Risk factors for corneal graft rejection after penetrating keratoplasty for keratoconus [J].
Alsubaie, Hamad ;
Alrubaian, Ahmad ;
Ahmad, Khabir ;
Ahad, Muhammad Ali .
INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
[34]   Histopathological examination of congenital corneal staphyloma and prognosis after penetrating keratoplasty [J].
Wan, Yu ;
Xiao, Gege ;
Yu, Ting ;
Zhang, Pei ;
Hong, Jing .
MEDICINE, 2020, 99 (40) :E21892
[35]   In vivo confocal microscopy of corneal grafts shortly after penetrating keratoplasty [J].
Szaflik, J. P. ;
Kaminska, A. ;
Udziela, M. ;
Szaflik, J. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (06) :891-896
[36]   Deep lamellar keratoplasty versus penetrating keratoplasty for corneal lesions [J].
Panda, A ;
Bageshwar, LMS ;
Ray, M ;
Singh, JP ;
Kumar, A .
CORNEA, 1999, 18 (02) :172-175
[37]   Resuturing after penetrating keratoplasty without trauma: Indications and results [J].
Singar, E. ;
Burcu, A. ;
Tamer-Kaderli, S. ;
Yalniz-Akkaya, Z. ;
Ozbek-Uzman, S. ;
Ornek, F. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2020, 43 (01) :18-24
[38]   Fourier series harmonic analysis of corneal topography following suture removal after penetrating keratoplasty [J].
Kagaya, F ;
Tomidokoro, A ;
Tanaka, S ;
Amano, S ;
Oshika, T .
CORNEA, 2002, 21 (03) :256-259
[39]   Consideration of the posterior corneal curvature for assessment of corneal power after myopic LASIK [J].
Langenbucher, A ;
Torres, F ;
Behrens, A ;
Suarez, E ;
Haigis, W ;
Seitz, B .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2004, 82 (03) :264-269
[40]   Penetrating keratoplasty in patients with traumatic corneal scarring [J].
Ozek, Dilay ;
Kemer, Oziem Evren ;
Onen, Mehmet ;
Karaca, Emine Esra .
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2019, 25 (02) :172-176