New electrode architectures based on poly(methylene green) and functionalized carbon nanotubes: Characterization and application to detection of acetaminophen and pyridoxine

被引:56
作者
Barsan, Madalina M. [1 ]
Toledo, Camilla T. [1 ,2 ]
Brett, Christopher M. A. [1 ]
机构
[1] Univ Coimbra, Fac Ciencias & Tecnol, Dept Quim, P-3004535 Coimbra, Portugal
[2] Univ Fed Vales Jequitinhonha & Mucuri, Inst Ciencia & Tecnol, Diamantina, MG, Brazil
关键词
Poly(methylene green); Composite electrodes; Carbon nanotubes; Acetaminophen; Pyridoxine; PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; BIOFUEL CELLS; ELECTROCHEMICAL SENSORS; ASCORBIC-ACID; VITAMIN-B-6; BIOSENSORS; OXIDATION; FILMS; PARACETAMOL;
D O I
10.1016/j.jelechem.2014.10.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New electrode platforms have been constructed containing the redox polymer poly(methylene green) (PMG) and functionalized carbon nanotubes (fCNT) in two configurations, the first containing MG electropolymerised on a graphite composite electrode (CE) and covered with fCNT (fCNT/PMG/CE), the second having the MG electropolymerised on top of fCNT modified CE (PMG/fCNT/CE). Modified electrodes with both configurations were characterized by cyclic voltammetry and electrochemical impedance spectroscopy, and compared with PMG/CE and fCNT/CE and CE, in order to evaluate the role of each component in the modified electrode architecture. The modified electrodes were applied to the detection of acetaminophen and pyridoxine, by fixed potential amperometry and differential pulse voltammetry, the latter allowing the simultaneous detection of both analytes. The analytical properties of fCNT/PMG/CE and PMG/fCNT/CE sensors were obtained and the best analytical performance compared with recently reported acetaminophen and pyridoxine sensors. Determination of both analytes in pharmaceutical samples was successfully performed. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 48 条
[1]   Chemical polymerization and electrochemical characterization of thiazines for NADH electrocatalysis applications [J].
Arechederra, Marguerite N. ;
Jenkins, Courtney ;
Rincon, Rosalba A. ;
Artyushkova, Kateryna ;
Atanassov, Plamen ;
Minteer, Shelley D. .
ELECTROCHIMICA ACTA, 2010, 55 (22) :6659-6664
[2]   Methylene blue delays cellular senescence and enhances key mitochondrial biochemical pathways [J].
Atamna, Hani ;
Nguyen, Andy ;
Schultz, Carla ;
Boyle, Kathleen ;
Newberry, Justin ;
Kato, Hiroyuki ;
Ames, Bruce N. .
FASEB JOURNAL, 2008, 22 (03) :703-712
[3]   Electrosynthesis and electrochemical characterisation of phenazine polymers for application in biosensors [J].
Barsan, Madalina M. ;
Pinto, Edilson M. ;
Brett, Christopher M. A. .
ELECTROCHIMICA ACTA, 2008, 53 (11) :3973-3982
[4]  
Barsoukov E, 2005, IMPEDANCE SPECTROSCOPY: THEORY, EXPERIMENT, AND APPLICATIONS, 2ND EDITION, pXII
[5]   Electrochemical behavior of a carbon paste electrode modified with 5-amino-3′,4′-dimethyl-biphenyl-2-ol/carbon nanotube and its application for simultaneous determination of isoproterenol, acetaminophen and N-acetylcysteine [J].
Beitollahi, Hadi ;
Mohadesi, Alireza ;
Mohammadi, Somayeh ;
Akbari, Ali .
ELECTROCHIMICA ACTA, 2012, 68 :220-226
[6]   Novel nanostructure-based electrochemical sensor for simultaneous determination of dopamine and acetaminophen [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (02) :375-380
[7]  
Blackwell AE, 2009, J NANOSCI NANOTECHNO, V9, P1714, DOI [10.1166/jnn.2009.SI04, 10.1166/jnn.2009.S104]
[8]   Voltammetric determination of vitamin B6 in food samples and dietary supplements [J].
Brunetti, Barbara ;
Desimoni, Elio .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2014, 33 (02) :155-160
[9]   A high performance electrochemical sensor for acetaminophen based on single-walled carbon nanotube-graphene nanosheet hybrid films [J].
Chen, Xu ;
Zhu, June ;
Xi, Qian ;
Yang, Wensheng .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :648-654
[10]   Flexible potentiometric minisensor based on manganese dioxide-composite for the determination of hydrogen peroxide in bleach and pharmaceutical products [J].
Fagury, RLRP ;
Lupetti, KO ;
Fatibello, O .
ANALYTICAL LETTERS, 2005, 38 (12) :1857-1867