Optimization of separation and detection of 6-aminoquinolyl derivatives of amino acids by using reversed-phase liquid chromatography with on line UV, fluorescence and electrochemical detection

被引:43
作者
Pappa-Louisi, A. [1 ]
Nikitas, P. [1 ]
Agrafiotou, P. [1 ]
Papageorgiou, A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Phys Chem Lab, Thessaloniki 54124, Greece
关键词
amino acids; reversed-phase liquid chromatography (RP-HPLC); 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC); separation optimization; ultraviolet-florescence-electrochemical (UV-FL-EC) detection;
D O I
10.1016/j.aca.2007.04.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combined use of UV-absorbance, fluorescence and electrochemical detection was proposed for the analysis of a set of thirteen amino acids by reversed-phase liquid chromatography (RP-HPLC) using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate as a precolumn derivatization reagent. The utility of using three detectors in series was demonstrated. The separation of all derivatized amino acids was optimized with the aid of a computer optimization program from only four simple linear gradient measurements. The effectiveness of a reliable retention prediction of solutes under any gradient profile using other gradient or isocratic data was also examined. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 25 条
[1]  
AGRAFIOTOU P, 2006, THESIS ARISTOTLE U T
[2]   Application of the 6-aminoquinolyl-N-hydroxysccinimidyl carbamate (AQC) reagent to the RP-HPLC determination of amino acids in infant foods [J].
Bosch, L ;
Alegría, A ;
Farré, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2) :176-183
[3]   Improved analytical methods for determination of nitrogenous stress metabolites occurring in Limonium species [J].
Bouchereau, A ;
Duhazé, C ;
Martin-Tanguy, J ;
Guégan, JP ;
Larher, F .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (02) :209-221
[4]   PREOPT-W: Off-line optimization of binary gradient separations in HPLC by simulation .4. Phase 3 [J].
Cela, R ;
Leira, E ;
Cabaleiro, O ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (03) :315-330
[5]   PREOPT-W: Off-line optimization of binary gradient separations in HPLC by simulation .3. Phase 2 and the objective functions [J].
Cela, R ;
Leira, E ;
Cabaleiro, O ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (03) :285-313
[6]   THE PREOPT PACKAGE FOR PRE-OPTIMIZATION OF GRADIENT ELUTIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CELA, R ;
BARROSO, CG ;
VISERAS, C ;
PEREZBUSTAMANTE, JA .
ANALYTICA CHIMICA ACTA, 1986, 191 :283-297
[7]   PREOPT-W: A simulation program for off-line optimization of binary gradient separations in HPLC .2. Data management and miscellaneous aspects of use [J].
Cela, R ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (02) :193-202
[8]   PREOPT-W: A simulation program for off-line optimization of binary gradient separations in HPLC .1. Fundamentals and overview [J].
Cela, R ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (02) :175-191
[9]   SYNTHESIS OF A FLUORESCENT DERIVATIZING REAGENT, 6-AMINOQUINOLYL-N-HYDROXYSUCCINIMIDYL CARBAMATE, AND ITS APPLICATION FOR THE ANALYSIS OF HYDROLYSATE AMINO-ACIDS VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COHEN, SA ;
MICHAUD, DP .
ANALYTICAL BIOCHEMISTRY, 1993, 211 (02) :279-287
[10]   Amino acid and amino sugar determination by derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate followed by high-performance liquid chromatography and fluorescence detection [J].
Diaz, J ;
Lliberia, JL ;
Comellas, L ;
BrotoPuig, F .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :171-179