The effect of perimodiolar placement on speech perception and frequency discrimination by cochlear implant users

被引:36
作者
Fitzgerald, Matthew B.
Shapiro, William H.
McDonald, Paulette D.
Neuburger, Heidi S.
Ashburn-Reed, Sara
Immerman, Sara
Jethanamest, Daniel
Roland, J. Thomas
Svirsky, Mario A.
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10016 USA
[2] Michigan Ear Inst, Farmington Hills, MI USA
[3] Indiana Univ, Sch Med, Dept Otolaryngol HNS, Indianapolis, IN USA
[4] Cochlear Amer, Denver, CO USA
关键词
D O I
10.1080/00016480701258671
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusion. Neither speech understanding nor frequency discrimination ability was better in Nucleus Contour (TM) users than in Nucleus 24 straight electrode users. Furthermore, perimodiolar electrode placement does not result in better frequency discrimination. Objectives. We addressed three questions related to perimodiolar electrode placement. First, do patients implanted with the Contour (TM) electrode understand speech better than with an otherwise identical device that has a straight electrode? Second, do these groups have different frequency discrimination abilities? Third, is the distance of the electrode from the modiolus related to frequency discrimination ability? Subjects and methods. Contour (TM) and straight electrode users were matched on four important variables. We then tested these listeners on CNC word and HINT sentence identification tasks, and on a formant frequency discrimination task. We also examined X-rays and measured the distance of the electrodes from the modiolus to determine whether there is a relationship between this factor and frequency discrimination ability. Results. Both speech understanding and frequency discrimination abilities were similar for listeners implanted with the Contour (TM) vs a straight electrode. Furthermore, there was no linear relationship between electrode - modiolus distance and frequency discrimination ability. However, we did note a second-order relationship between these variables, suggesting that frequency discrimination is worse when the electrodes are either too close or too far away from the modiolus.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 21 条
[1]   Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems [J].
Bacciu, A ;
Pasanisi, E ;
Vincenti, V ;
Guida, M ;
Barbot, A ;
Berghenti, M ;
Forli, F ;
Berrettini, S ;
Bacciu, S .
ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) :1155-1158
[2]   Electrode discrimination by early-deafened subjects using the Cochlear Limited multiple-electrode cochlear implant [J].
Busby, PA ;
Clark, GM .
EAR AND HEARING, 2000, 21 (04) :291-304
[3]   A psychophysical forward masking comparison of longitudinal spread of neural excitation in the Contour™ and straight Nucleus® electrode arrays [J].
Cohen, LT ;
Lenarz, T ;
Battmer, RD ;
von Saebelkampf, CB ;
Busby, PA ;
Cowan, RSC .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2005, 44 (10) :559-566
[4]   Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward masking [J].
Cohen, LT ;
Richardson, LM ;
Saunders, E ;
Cowan, RSC .
HEARING RESEARCH, 2003, 179 (1-2) :72-87
[5]   Psychophysics of a prototype peri-modiolar cochlear implant electrode array [J].
Cohen, LT ;
Saunders, E ;
Clark, GM .
HEARING RESEARCH, 2001, 155 (1-2) :63-81
[6]  
Cohen LT, 1996, AM J OTOL, V17, P859
[7]   Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor [J].
Fishman, KE ;
Shannon, RV ;
Slattery, WH .
JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 1997, 40 (05) :1201-1215
[8]   Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea [J].
Frijns, JHM ;
deSnoo, SL ;
tenKate, JH .
HEARING RESEARCH, 1996, 95 (1-2) :33-48
[9]   The relationship between speech perception and electrode discrimination in cochlear implantees [J].
Henry, BA ;
McKay, CM ;
McDermott, HJ ;
Clark, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (03) :1269-1280
[10]   Electrophysiologic channel interaction, electrode pitch ranking, and behavioral threshold in straight versus perimodiolar cochlear implant electrode arrays [J].
Hughes, ML ;
Abbas, PJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (03) :1538-1547