Desorption of CO2 from activated carbon fibre-phenolic resin composite by electrothermal effect

被引:19
作者
An, Hui [1 ]
Feng, Bo [1 ]
机构
[1] Univ Queensland, Sch Engn, St Lucia, Qld 4072, Australia
关键词
CO2; capture; Electrothermal swing adsorption; Activated carbon fibre-phenolic resin composite; ELECTRIC SWING ADSORPTION; GAS SEPARATION; CAPTURE; REGENERATION; REMOVAL; CLOTH;
D O I
10.1016/j.ijggc.2009.06.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
CO2 capture by electrothermal swing adsorption is considered superior over conventional adsorption approaches: temperature swing adsorption and pressure swing adsorption. In this work, the effects of electricity, preheating and flow rate were studied. An increase in energy input by electricity has been found able to improve desorption performance more significantly than an increase in current level. However, higher current level is recommended because it can minimise energy loss while passing electricity. Higher flow rate can also be beneficial due to the improved desorption rate and reduced desorption time. However, there is a drop in CO2 concentration in the effluent gas. When desorption takes place at a high current level, preheating is not required as it extends desorption duration with no obvious improvement in desorption rate. CO2 capture by electrothermal swing adsorption has also been tested with different concentrations of CO2. It is found that electrothermal swing adsorption can be more energy efficient while dealing with higher concentration CO2. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 19 条
[1]   CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Schneiders, Leon H. J. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) :37-46
[2]   Simulation of CO2 capture using MEA scrubbing:: a flowsheet decomposition method [J].
Alie, C ;
Backham, L ;
Croiset, E ;
Douglas, PL .
ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (03) :475-487
[3]   CO2 capture capacities of activated carbon fibre-phenolic resin composites [J].
An, Hui ;
Feng, Bo ;
Su, Shi .
CARBON, 2009, 47 (10) :2396-2405
[4]   THERMAL REGENERATION BY JOULE EFFECT OF ACTIVATED CARBON USED FOR AIR TREATMENT [J].
BAUDU, M ;
LECLOIREC, P ;
MARTIN, G .
ENVIRONMENTAL TECHNOLOGY, 1992, 13 (05) :423-435
[5]   Passive CO2 removal using a carbon fiber - Composite molecular sieve [J].
Burchell, TD ;
Judkins, RR .
ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (6-8) :947-954
[6]   A novel process and material for the separation of carbon dioxide and hydrogen sulfide gas mixtures [J].
Burchell, TD ;
Judkins, RR ;
Rogers, MR ;
Williams, AM .
CARBON, 1997, 35 (09) :1279-1294
[7]   Redistribution of adsorbed VOCs in activated carbon under electrothermal desorption [J].
Cheng, ZM ;
Yu, FD ;
Grevillot, G ;
Luo, L ;
Tondeur, D ;
Yuan, WK .
AICHE JOURNAL, 2002, 48 (05) :1132-1138
[8]  
CHINN MJ, 2002, NBC DEF COLL PROT C
[9]   Organic vapor recovery and energy efficiency during electric regeneration of an activated carbon fiber cloth adsorber [J].
Dombrowski, KD ;
Lehmann, CMB ;
Sullivan, PD ;
Ramirez, D ;
Rood, MJ ;
Hay, KJ .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2004, 130 (03) :268-275
[10]  
Economy J., 1976, APPL POLYM SYMP, V29, P199