Overranging at Multisection CT: An Underestimated Source of Excess Radiation Exposure

被引:61
作者
Schilham, Arnold [1 ]
van der Molen, Aart J. [2 ]
Prokop, Mathias [1 ]
de Jong, Hugo W. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
关键词
COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; MULTIDETECTOR CT; TISSUES;
D O I
10.1148/rg.304095167
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To reconstruct the first and last sections of a helical computed tomographic (CT) scan, the scan length is automatically extended beyond the planned image boundaries, a phenomenon known as overranging. With common 16-section CT scanning protocols, the overrange length is between 3 and 6 cm. For scanners with 64 or more sections, this length will be much greater, since overranging increases as pitch or detector collimation increases. Manufacturers have equipped the latest generation of CT scanners (128 sections or more) with overrange dose reducing innovations that reduce overranging by typically up to 50%, which in the best cases reduces overranging to that of the previous scanner models (64 sections). To reduce the impact of overranging on radiosensitive organs just outside the planned scan region, it is best to use an axial protocol rather than a helical protocol. If this is not an option, lowering the pitch or the detector collimation will significantly reduce overranging. Finally, CT examinations should be planned in such a way that radiosensitive organs are as far as possible from the imaged volume. (c) RSNA, 2010 . radiographics.rsna.org
引用
收藏
页码:1057 / 1067
页数:11
相关论文
共 21 条
[1]  
[Anonymous], 2003, Ann ICRP, V33, P1, DOI [10.1016/S0146-6453(03)00024-1, DOI 10.1016/S0146-6453(03)00024-1]
[2]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[3]   Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume [J].
Boone, JM ;
Cooper, VN ;
Nemzek, WR ;
McGahan, JP ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2393-2407
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   AAPM/RSNA physics tutorial for residents - Technologic advances in multidetector CT with a focus on cardiac imagingi [J].
Cody, Dianna D. ;
Mahesh, Mahadevappa .
RADIOGRAPHICS, 2007, 27 (06) :1829-1837
[6]   Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality [J].
Geleijns, J. ;
Salvado Artells, M. ;
Veldkamp, W. J. H. ;
Lopez Tortosa, M. ;
Calzado Cantera, A. .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2334-2340
[7]  
Hopper KD, 2001, AM J NEURORADIOL, V22, P1194
[8]   The impact of scan length on the exposure levels in 16-and 64-row multidetector computed tomography: A phantom study [J].
Irwan, Roy ;
de Vries, Henk B. K. ;
Sijens, Paul E. .
ACADEMIC RADIOLOGY, 2008, 15 (09) :1142-1147
[9]   Measurement of CT radiation profile width using CR imaging plates [J].
Liu, HL ;
Liu, RJR ;
Reeve, DM ;
Shepard, SJ ;
Willis, CE .
MEDICAL PHYSICS, 2005, 32 (09) :2881-2887
[10]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719