In vivo detection of carnosine and its derivatives using chemical exchange saturation transfer

被引:1
|
作者
Bardin, Solene [1 ]
Lecis, Michele [1 ]
Boido, Davide [1 ]
Boutin, Celine [2 ]
Baron, Giovanna [3 ]
Aldini, Giancarlo [3 ]
Berthault, Patrick [2 ]
Boumezbeur, Fawzi [1 ]
Ciobanu, Luisa [1 ]
机构
[1] Paris Saclay Univ, UMR CEA CNRS 9027, NeuroSpin, Gif Sur Yvette, France
[2] UMR CEA CNRS 3685, IRAMIS, NIMBE, Lab Struct & Dynam Resonance Magnet, Gif Sur Yvette, France
[3] Univ Milan, Med Chem Sect Pietro Pratesi, Dept Pharmaceut Sci, Milan, Italy
关键词
carnosine; chemical exchange saturation transfer; histidine dipeptides; in vivo MRS; mass spectrometry; ultra-high field; AMIDE PROTON-TRANSFER; BETA-ALANINE; HOMOCARNOSINE; BRAIN; DIPEPTIDES; MUSCLE; SPECTROSCOPY; HISTIDINE; CONTRAST; MRI;
D O I
10.1002/mrm.29282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To detect carnosine, anserine and homocarnosine in vivo with chemical exchange saturation transfer (CEST) at 17.2 T. Methods CEST MR acquisitions were performed using a CEST-linescan sequence developed in-house and optimized for carnosine detection. In vivo CEST data were collected from three different regions of interest (the lower leg muscle, the olfactory bulb and the neocortex) of eight rats. Results The CEST effect for carnosine, anserine and homocarnosine was characterized in phantoms, demonstrating the possibility to separate individual contributions by employing high spectral resolution (0.005 ppm) and low CEST saturation power (0.15 mu$$ \mu $$T). The CEST signature of these peptides was evidenced, in vivo, in the rat brain and skeletal muscle. The presence of carnosine and anserine in the muscle was corroborated by in vivo localized spectroscopy (MRS). However, the sensitivity of MRS was insufficient for carnosine and homocarnosine detection in the brain. The absolute amounts of carnosine and derivatives in the investigated tissues were determined by liquid chromatography-electrospray ionization-tandem mass spectrometry using isotopic dilution standard methods and were in agreement with the CEST results. Conclusion The robustness of the CEST-linescan approach and the favorable conditions for CEST at ultra-high magnetic field allowed the in vivo CEST MR detection of carnosine and related peptides. This approach could be useful to investigate noninvasively the (patho)-physiological roles of these molecules.
引用
收藏
页码:1314 / 1323
页数:10
相关论文
共 50 条
  • [1] An Amyloid-β Targeting Chemical Exchange Saturation Transfer Probe for In Vivo Detection of Alzheimer's Disease
    Wang, Runrun
    Wang, Chenwei
    Dai, Zhuozhi
    Chen, Yanzi
    Shen, Zhiwei
    Xiao, Gang
    Chen, Yuanfeng
    Zhou, Jiang-Ning
    Zhuang, Zerui
    Wu, Renhua
    ACS CHEMICAL NEUROSCIENCE, 2019, 10 (08): : 3859 - 3867
  • [2] Detection and Quantification of Hydrogen Peroxide in Aqueous Solutions Using Chemical Exchange Saturation Transfer
    Ryoo, David
    Xu, Xiang
    Li, Yuguo
    Tang, Joel A.
    Zhang, Jia
    van Zijl, Peter C. M.
    Liu, Guanshu
    ANALYTICAL CHEMISTRY, 2017, 89 (14) : 7758 - 7764
  • [3] A rapid method for phosphocreatine-weighted imaging in muscle using double saturation power-chemical exchange saturation transfer
    Viswanathan, Malvika
    Kurmi, Yashwant
    Zu, Zhongliang
    NMR IN BIOMEDICINE, 2024, 37 (04)
  • [4] Design Chemical Exchange Saturation Transfer Contrast Agents and Nanocarriers for Imaging Proton Exchange in Vivo
    Su, Haoyun
    Chan, Kannie W. Y.
    ACS NANO, 2024, 18 (50) : 33775 - 33791
  • [5] Progress toward quantitative in vivo chemical exchange saturation transfer (CEST) MRI
    Ji, Yang
    Zhou, Iris Yuwen
    Qiu, Bensheng
    Sun, Phillip Zhe
    ISRAEL JOURNAL OF CHEMISTRY, 2017, 57 (09) : 809 - 824
  • [6] Magnetic Resonance Imaging using Chemical Exchange Saturation Transfer
    Park, Jaeseok
    NANOSYSTEMS IN ENGINEERING AND MEDICINE, 2012, 8548
  • [7] Chemical exchange saturation transfer for detection of antiretroviral drugs in brain tissue
    Bade, Aditya N.
    Gendelman, Howard E.
    McMillan, JoEllyn
    Liu, Yutong
    AIDS, 2021, 35 (11) : 1733 - 1741
  • [8] Investigation of chemical exchange at intermediate exchange rates using a combination of chemical exchange saturation transfer (CEST) and spin-locking methods (CESTrho)
    Kogan, Feliks
    Singh, Anup
    Cai, Keija
    Haris, Mohammad
    Hariharan, Hari
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 107 - 119
  • [9] In Vivo Mapping and Quantification of Creatine Using Chemical Exchange Saturation Transfer Imaging in Rat Models of Epileptic Seizure
    Lee, Dong-Hoon
    Lee, Do-Wan
    Kwon, Jae-Im
    Woo, Chul-Woong
    Kim, Sang-Tae
    Lee, Jin Seong
    Choi, Choong Gon
    Kim, Kyung Won
    Kim, Jeong Kon
    Woo, Dong-Cheol
    MOLECULAR IMAGING AND BIOLOGY, 2019, 21 (02) : 232 - 239
  • [10] In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T
    Jones, Craig K.
    Polders, Daniel
    Hua, Jun
    Zhu, He
    Hoogduin, Hans J.
    Zhou, Jinyuan
    Luijten, Peter
    van Zijl, Peter C. M.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1579 - 1589