Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation

被引:141
作者
Mendelsohn, Daniel [1 ,2 ,3 ]
Strelzow, Jason [1 ,2 ,3 ]
Dea, Nicolas [1 ,2 ,3 ]
Ford, Nancy L. [1 ,2 ,3 ]
Batke, Juliet [1 ,2 ,3 ]
Pennington, Andrew [1 ,2 ]
Yang, Kaiyun [1 ,2 ]
Ailon, Tamir [1 ,2 ]
Boyd, Michael [1 ,2 ]
Dvorak, Marcel [1 ,2 ,3 ]
Kwon, Brian [1 ,2 ]
Paquette, Scott [1 ,2 ]
Fisher, Charles [1 ,2 ,3 ]
Street, John [1 ,2 ,3 ]
机构
[1] Univ British Columbia, Dept Orthoped, Vancouver Gen Hosp, Combined Neurosurg & Orthoped Spine Program, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Neurosurg, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Vancouver, BC V5Z 1M9, Canada
关键词
Complications; CT based navigation; Efficacy; Pedicle screw; Pedicle Screw Accuracy; Radiation exposure; Risk; Safety; Spine instrumentation; Spine navigation; PEDICLE SCREW PLACEMENT; IMAGE GUIDANCE; ASSISTED FLUOROSCOPY; ACCURACY; FIXATION; FUSION; SYSTEM; COMPLICATIONS; REDUCTION; INSERTION;
D O I
10.1016/j.spinee.2015.11.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Imaging modalities used to visualize spinal anatomy intraoperatively include X-ray studies, fluoroscopy, and computed tomography (CT). All of these emit ionizing radiation. PURPOSE: Radiation emitted to the patient and the surgical team when performing surgeries using intraoperative CT-based spine navigation was compared. STUDY DESIGN/SETTING: This is a retrospective cohort case-control study. PATIENT SAMPLE: Seventy-three patients underwent CT-navigated spinal instrumentation and 73 matched controls underwent spinal instrumentation with conventional fluoroscopy. OUTCOME MEASURES: Effective doses of radiation to the patient when the surgical team was inside and outside of the room were analyzed. The number of postoperative imaging investigations between navigated and non-navigated cases was compared. METHODS: Intraoperative X-ray imaging, fluoroscopy, and CT dosages were recorded and standardized to effective doses. The number of postoperative imaging investigations was compared with the matched cohort of surgical cases. A literature review identified historical radiation exposure values for fluoroscopic-guided spinal instrumentation. RESULTS: The 73 navigated operations involved an average of 5.44 levels of instrumentation. Thoracic and lumbar instrumentations had higher radiation emission from all modalities (CT, X-ray imaging, and fluoroscopy) compared with cervical cases (6.93 millisievert [mSv] vs. 2.34 mSv). Major deformity and degenerative cases involved more radiation emission than trauma or oncology cases (7.05 mSv vs. 4.20 mSv). On average, the total radiation dose to the patient was 8.7 times more than the radiation emitted when the surgical team was inside the operating room. Total radiation exposure to the patient was 2.77 times the values reported in the literature for thoracolumbar instrumentations performed without navigation. In comparison, the radiation emitted to the patient when the surgical team was inside the operating room was 2.50 lower than non-navigated thoracolumbar instrumentations. The average total radiation exposure to the patient was 5.69 mSv, a value less than a single routine lumbar CT scan (7.5 mSv). The average radiation exposure to the patient in the present study was approximately one quarter the recommended annual occupational radiation exposure. Navigation did not reduce the number of postoperative X-rays or CT scans obtained. CONCLUSIONS: Intraoperative CT navigation increases the radiation exposure to the patient and reduces the radiation exposure to the surgeon when compared with values reported in the literature. Intraoperative CT navigation improves the accuracy of spine instrumentation with acceptable patient radiation exposure and reduced surgical team exposure. Surgeons should be aware of the implications of radiation exposure to both the patient and the surgical team when using intraoperative CT navigation. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:343 / 354
页数:12
相关论文
共 64 条
[1]  
AAPM, 2008, 96 AAPM
[2]   Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery [J].
Abul-Kasim, Kasim ;
Soderberg, Marcus ;
Selariu, Eufrozina ;
Gunnarsson, Mikael ;
Kherad, Mehrsa ;
Ohlin, Acke .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (01) :52-58
[3]   Radiation Exposure to the Surgeon During Percutaneous Endoscopic Lumbar Discectomy A Prospective Study [J].
Ahn, Yong ;
Kim, Chang-Ho ;
Lee, June Ho ;
Lee, Sang-Ho ;
Kim, Jin-Sung .
SPINE, 2013, 38 (07) :617-625
[4]  
[Anonymous], 1998, LETT REP
[5]  
[Anonymous], 2009, National Council on Radiation Protection and Measurement report No. 160: Ionizing radiation exposure of the population of the United States
[6]   Use of CT-Based Intraoperative Spinal Navigation: Management of Radiation Exposure to Operator, Staff, and Patients [J].
Bandela, John R. ;
Jacob, R. Patrick ;
Arreola, Manuel ;
Griglock, Thomas M. ;
Bova, Frank ;
Yang, Mu .
WORLD NEUROSURGERY, 2013, 79 (02) :390-394
[7]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[8]   Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion [J].
Bindal, Rajesh K. ;
Glaze, Sharon ;
Ognoskie, Meghann ;
Tunner, Van ;
Malone, Robert ;
Ghosh, Subrata .
JOURNAL OF NEUROSURGERY-SPINE, 2008, 9 (06) :570-573
[9]  
Bottollier-Depois JF, 2000, RADIAT RES, V153, P526, DOI 10.1667/0033-7587(2000)153[0526:AETCRD]2.0.CO
[10]  
2