In-vivo X-ray Dark-Field Chest Radiography of a Pig

被引:82
作者
Gromann, Lukas B. [1 ,2 ]
De Marco, Fabio [1 ,2 ]
Willer, Konstantin [1 ,2 ]
Noel, Peter B. [1 ,2 ,3 ]
Scherer, Kai [1 ,2 ]
Renger, Bernhard [3 ]
Gleich, Bernhard [4 ]
Achterhold, Klaus [1 ,2 ]
Fingerle, Alexander A. [1 ,2 ,3 ]
Muenzel, Daniela [1 ,2 ,3 ]
Auweter, Sigrid [5 ]
Hellbach, Katharina [5 ]
Reiser, Maximilian [5 ]
Baehr, Andrea [6 ]
Dmochewitz, Michaela [6 ]
Schroeter, Tobias J. [7 ]
Koch, Frieder J. [7 ]
Meyer, Pascal [7 ]
Kunka, Danays [7 ]
Mohr, Juergen [7 ]
Yaroshenko, Andre [1 ,2 ,8 ]
Maack, Hanns-Ingo [8 ]
Pralow, Thomas [8 ]
van der Heijden, Hendrik [8 ]
Proksa, Roland [9 ]
Koehler, Thomas [9 ,10 ]
Wieberneit, Nataly [8 ]
Rindt, Karsten [8 ]
Rummeny, Ernst J. [3 ]
Pfeiffer, Franz [1 ,2 ,3 ,10 ]
Herzen, Julia [1 ,2 ]
机构
[1] Tech Univ Munich, Chair Biomed Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn, D-85748 Garching, Germany
[3] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, D-81675 Munich, Germany
[4] Tech Univ Munich, Inst Med Engn, D-85748 Garching, Germany
[5] Ludwig Maximilian Univ Hosp Munich, Inst Clin Radiol, D-81377 Munich, Germany
[6] Ludwig Maximilians Univ Munchen, Inst Mol Anim Breeding & Biotechnol, D-85764 Oberschleissheim, Germany
[7] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Eggenstein Leopoldshafen, Germany
[8] Philips Med Syst DMC GmbH, D-22335 Hamburg, Germany
[9] Philips GmbH Innovat Technol, Res Labs, D-22335 Hamburg, Germany
[10] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
基金
欧洲研究理事会;
关键词
DIAGNOSIS; SCATTERING; LUNG;
D O I
10.1038/s41598-017-05101-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the first in-vivo XDF full-field chest radiographs (32 x 35 cm(2)) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 mu Sv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.
引用
收藏
页数:7
相关论文
共 31 条
[11]   Grating interferometer based scanning setup for hard x-ray phase contrast imaging [J].
Kottler, C. ;
Pfeiffer, F. ;
Bunk, O. ;
Gruenzweig, C. ;
David, C. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04)
[12]   Increasing the field of view in grating based X-ray phase contrast imaging using stitched gratings [J].
Meiser, J. ;
Willner, M. ;
Schroeter, T. ;
Hofmann, A. ;
Rieger, J. ;
Koch, F. ;
Birnbacher, L. ;
Schuettler, M. ;
Kunka, D. ;
Meyer, P. ;
Faisal, A. ;
Amberger, M. ;
Duttenhofer, T. ;
Weber, T. ;
Hipp, A. ;
Ehn, S. ;
Walter, M. ;
Herzen, J. ;
Schulz, J. ;
Pfeiffer, F. ;
Mohr, J. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) :379-388
[13]   Effective doses in radiology and diagnostic nuclear medicine: A catalog [J].
Mettler, Fred A., Jr. ;
Huda, Walter ;
Yoshizumi, Terry T. ;
Mahesh, Mahadevappa .
RADIOLOGY, 2008, 248 (01) :254-263
[14]   Small angle x-ray scattering with edge-illumination [J].
Modregger, Peter ;
Cremona, Tiziana P. ;
Benarafa, Charaf ;
Schittny, Johannes C. ;
Olivo, Alessandro ;
Endrizzi, Marco .
SCIENTIFIC REPORTS, 2016, 6
[15]   Recent advances in X-ray phase imaging [J].
Momose, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (9A) :6355-6367
[16]  
Momose A., 2003, JAPANESE J APPL PH 2, V42
[17]   A beam hardening and dispersion correction for x-ray dark-field radiography [J].
Pelzer, Georg ;
Anton, Gisela ;
Horn, Florian ;
Rieger, Jens ;
Ritter, Andre ;
Wandner, Johannes ;
Weber, Thomas ;
Michel, Thilo .
MEDICAL PHYSICS, 2016, 43 (06) :2774-2779
[18]   Hard-X-ray dark-field imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Kraft, P. ;
Eikenberry, E. F. ;
Broennimann, Ch. ;
Gruenzweig, C. ;
David, C. .
NATURE MATERIALS, 2008, 7 (02) :134-137
[19]   Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources [J].
Pfeiffer, F ;
Weitkamp, T ;
Bunk, O ;
David, C .
NATURE PHYSICS, 2006, 2 (04) :258-261
[20]   Quantitative imaging using high-energy X-ray phase-contrast CT with a 70 kVp polychromatic X-ray spectrum [J].
Sarapata, Adrian ;
Willner, Marian ;
Walter, Marco ;
Duttenhofer, Thomas ;
Kaiser, Konradin ;
Meyer, Pascal ;
Braun, Christian ;
Fingerle, Alexander ;
Noeel, Peter B. ;
Pfeiffer, Franz ;
Herzen, Julia .
OPTICS EXPRESS, 2015, 23 (01) :523-535