Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams

被引:1
|
作者
Mizutani, Shohei [1 ]
Takada, Yoshihisa [1 ]
Kohno, Ryosuke [2 ]
Hotta, Kenji [2 ]
Tansho, Ryohei [1 ]
Akimoto, Tetsuo [2 ]
机构
[1] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki, Japan
[2] Natl Canc Ctr Hosp East, Res Ctr Innovat Oncol, Particle Therapy Div, Chiba, Japan
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 02期
关键词
dose kernel calculation; simplified Monte Carlo method; treatment planning system; nasopharyngeal tumor case; proton pencil beam scanning; PARTICLE THERAPY; CLINICAL IMPLEMENTATION; SYSTEM; IRRADIATION; ALGORITHM; ACCURACY;
D O I
10.1120/jacmp.v17i2.5747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Full Monte Carlo (FMC) calculation of dose distribution has been recognized to have superior accuracy, compared with the pencil beam algorithm (PBA). However, since the FMC methods require long calculation time, it is difficult to apply them to routine treatment planning at present. In order to improve the situation, a simplified Monte Carlo (SMC) method has been introduced to the dose kernel calculation applicable to dose optimization procedure for the proton pencil beam scanning. We have evaluated accuracy of the SMC calculation by comparing a result of the dose kernel calculation using the SMC method with that using the FMC method in an inhomogeneous phantom. The dose distribution obtained by the SMC method was in good agreement with that obtained by the FMC method. To assess the usefulness of SMC calculation in clinical situations, we have compared results of the dose calculation using the SMC with those using the PBA method for three clinical cases of tumor treatment. The dose distributions calculated with the PBA dose kernels appear to be homogeneous in the planning target volumes (PTVs). In practice, the dose distributions calculated with the SMC dose kernels with the spot weights optimized with the PBA method show largely inhomogeneous dose distributions in the PTVs, while those with the spot weights optimized with the SMC method have moderately homogeneous distributions in the PTVs. Calculation using the SMC method is faster than that using the GEANT4 by three orders of magnitude. In addition, the graphic processing unit (GPU) boosts the calculation speed by 13 times for the treatment planning using the SMC method. Thence, the SMC method will be applicable to routine clinical treatment planning for reproduction of the complex dose distribution more accurately than the PBA method in a reasonably short time by use of the GPU-based calculation engine.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 50 条
  • [41] A general method to derive tissue parameters for Monte Carlo dose calculation with multi-energy CT
    Lalonde, Arthur
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (22) : 8044 - 8069
  • [42] Point dose comparison of Monte Carlo and pencil beam algorithms in treatment planning system for proton therapy
    Monkongsubsin, Wiroon
    Keawsamur, Mintra
    Sanghangthum, Taweap
    Ayuthaya, Isra Israngkul Na
    HEALTH AND TECHNOLOGY, 2024,
  • [43] Development and evaluation of dose calculation algorithm with a combination of Monte Carlo and point-kernel methods for boron neutron capture therapy
    Nojiri, Mai
    Takata, Takushi
    Hu, Naonori
    Sakurai, Yoshinori
    Suzuki, Minoru
    Tanaka, Hiroki
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [44] Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code
    Boiset, Gisell Ruiz
    Batista, Delano V. S.
    Cardoso, Simone Coutinho
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 1 - 10
  • [45] Dose Calculation in a Mouse Lung Tumor and in Secondary Organs During Radiotherapy Treatment: A Monte Carlo Study
    Hamdi, Mahdjoub
    Mimi, Malika
    Bentourkia, M'hamed
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2015), PT I, 2015, 9043 : 360 - 367
  • [46] GRID-ENABLED TREATMENT PLANNING FOR PROTON THERAPY USING MONTE CARLO SIMULATIONS
    Vadapalli, Ravi
    Yepes, Pablo
    Newhauser, Wayne
    Lichti, Roger
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 16 - 21
  • [47] Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer
    Yepes, Pablo
    Randeniya, Sharmalee
    Taddei, Phillip J.
    Newhauser, Wayne D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) : N21 - N28
  • [48] Independent absorbed-dose calculation using the Monte Carlo algorithm in volumetric modulated arc therapy
    Akihiro Haga
    Taiki Magome
    Shigeharu Takenaka
    Toshikazu Imae
    Akira Sakumi
    Akihiro Nomoto
    Hiroshi Igaki
    Kenshiro Shiraishi
    Hideomi Yamashita
    Kuni Ohtomo
    Keiichi Nakagawa
    Radiation Oncology, 9
  • [49] An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity
    Bueno, M.
    Paganetti, H.
    Duch, M. A.
    Schuemann, J.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [50] Comparison of CCC and ETAR dose calculation algorithms in pituitary adenoma radiation treatment planning; Monte Carlo evaluation
    Tanha, K.
    Mahdavi, S. R.
    Geraily, G.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2014, 13 (04) : 447 - 455