Removal of fluoride from electronic industrial effluent by RO membrane separation

被引:235
作者
Ndiayea, PI
Moulin, P [1 ]
Dominguez, L
Millet, JC
Charbit, F
机构
[1] Univ Aix Marseille 3, LPPE, UMR 6181, F-13545 Aix En Provence 04, France
[2] ZI Pradeux, Rockwood Elect Mat, Wafer Reclaim France, F-13850 Greasque, France
关键词
fluoride; reverse osmosis (RO); wastewater; electronic industry;
D O I
10.1016/j.desal.2004.07.042
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The electronics industry generates large amounts of fluoride-containing effluents. The objective of this study is to study the feasibility of applying reverse osmosis (RO) membrane separation to reduce fluoride load to less than 1 kg/d. The effect of transmembrane pressure on the removal of fluoride ion has been investigated in detail, and the design parameters of a small RO separation unit were estimated. The present study indicated that the rejection of fluoride ion is typically higher than 98%, considering that the RO membrane was fully regenerated after each set of experiments. The effect of upstream concentration on the required mechanical pressure was determined by estimating the theoretical osmotic pressure of the feed solution. For industrial effluents, the process developed in this work allows us to reduce the treated volume from 6 m(3)/d to 0.36 m(3)/d without any pretreatment or adding additional compounds. The cost of the designed RO separation plant (Euro76,000) is much less than that of the conventional treatment (Euro533/m(3)) that deals mainly with volumes rather than specific fluoride removal.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 21 条
[1]   FLUORIDE ADSORPTION ON FISHBONE CHARCOAL THROUGH A MOVING-MEDIA ADSORBER [J].
BHARGAVA, DS ;
KILLEDAR, DJ .
WATER RESEARCH, 1992, 26 (06) :781-788
[2]   SELECTIVE SORPTION OF FLUORIDE IONS BY ANION-EXCHANGE RESIN MODIFIED WITH ALIZARIN FLUORINE BLUE PRASEODYMIUM(III) COMPLEX [J].
CHIKUMA, M ;
NISHIMURA, M .
REACTIVE POLYMERS, 1990, 13 (1-2) :131-138
[3]   Water type and guidelines for RO system design [J].
El-Manharawy, S ;
Hafez, A .
DESALINATION, 2001, 139 (1-3) :97-113
[4]   Activated alumina for removing fluorides from drinking water [J].
Fink, GJ ;
Lindsay, FK .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1936, 28 :947-948
[5]   Ultrafiltration behavior of major ions (Na, Ca, Mg, F, Cl, and SO4) in natural waters [J].
Guo, LD ;
Hunt, BJ ;
Santschi, PH .
WATER RESEARCH, 2001, 35 (06) :1500-1508
[6]  
HARON MJ, 1995, J ENV STUDIES, V48, P245
[7]   Fluoride removal from diluted solutions by Donnan dialysis with anion-exchange membranes [J].
Hichour, M ;
Persin, F ;
Molénat, J ;
Sandeaux, J ;
Gavach, C .
DESALINATION, 1999, 122 (01) :53-62
[8]   Fluoride removal from waters by Donnan dialysis [J].
Hichour, M ;
Persin, F ;
Sandeaux, J ;
Gavach, C .
SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 18 (01) :1-11
[9]  
HINDIN E, 1968, COLL ENG RES DIV B, V310
[10]   Integrated biological and physiochemical treatment process for nitrate and fluoride removal [J].
Mekonen, A ;
Kumar, P ;
Kumar, A .
WATER RESEARCH, 2001, 35 (13) :3127-3136