Behavior of Polypropylene Fiber-Reinforced Concrete Beams in Fire

被引:6
作者
Rezaeian, Abbas [1 ]
Daghari, Amir [1 ]
Kodur, Venkatesh [2 ]
机构
[1] Shahid Chamran Univ Ahvaz, Ahvaz, Khuzestan, Iran
[2] Michigan State Univ, E Lansing, MI 48824 USA
关键词
elevated temperature; fiber-reinforced; fire-induced spalling; fire resistance; polypropylene (PP) fibers; reinforced concrete (RC) beam; RESISTANCE; PERFORMANCE;
D O I
10.14359/51735947
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental study on the comparative response of polypropylene (PP) fiber-incorporated reinforced concrete (RC) beams under fire conditions. Five full-scale RC beam specimens, made with different batch mixtures comprising normal plain concrete (NPC) and fiber-reinforced concrete (FRC), were tested to assess their spalling performance and structural behavior under fire conditions. The main variables in the experiments were the amount and length of PP fibers. Deflections, temperatures, and spalling in the beams were monitored during fire exposure. FRC beams' flexural failure occurs after 151 minutes at heating temperatures beyond 850 degrees C, when deflections exceed span/20. When the concrete contains PP fibers (that is, FRC beams), the gamut of fire-induced spalling in RC beams gets reduced, increasing the fire resistance from 147 to 171 minutes (approximately 17%). Furthermore, test results show that adding 2 to 3 kg/m(3) of PP fibers effectively releases the pore pressure through tensile cracking and reduces the amount of spalling in the FRC beams.
引用
收藏
页码:24 / 34
页数:11
相关论文
共 40 条
[1]   Residual response of fire-damaged high-strength concrete beams [J].
Agrawal, Ankit ;
Kodur, Venkatesh .
FIRE AND MATERIALS, 2019, 43 (03) :310-322
[2]   Behavior of thermally restrained RC beams in case of fire [J].
Albuquerque, Gabriela L. ;
Silva, Augusto B. ;
Rodrigues, Joao Paulo C. ;
Silva, Valdir P. .
ENGINEERING STRUCTURES, 2018, 174 :407-417
[3]   Influence of polypropylene and steel fibres on thermal spalling and physical-mechanical properties of concrete under different heating rates [J].
Algourdin, N. ;
Pliya, P. ;
Beaucour, A-L ;
Simon, A. ;
Noumowe, A. .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 259
[4]   Outcomes of a major research on fire resistance of concrete columns [J].
Ali, F ;
Nadjai, A ;
Silcock, G ;
Abu-Tair, A .
FIRE SAFETY JOURNAL, 2004, 39 (06) :433-445
[5]   Temperature-induced transient creep strain in fiber-reinforced concrete [J].
Alogla, S. M. ;
Kodur, V .
CEMENT & CONCRETE COMPOSITES, 2020, 113
[6]  
[Anonymous], 2010, C143C143M10 ASTM INT
[7]  
[Anonymous], 1987, Fire Tests on Building Materials and StructuresPart 20. Method of Test for Determination of the Fire Resistance of Elements of Construction (General Principles)
[8]  
[Anonymous], 2016, C150C150M16E1 ASTM I
[9]  
[Anonymous], 2014, 216 ACITMS COMM
[10]  
[Anonymous], 2014, An ACI Standard and Report: Building Code Requirements for Structural Concrete (ACI 318-14), P524