Performance evaluation of non-uniform illumination on a transverse bifacial PVT receiver in combination with a CPC geometry

被引:15
作者
Cabral, Diogo [1 ]
Gomes, Joao [1 ]
Karlsson, Bjorn [1 ]
机构
[1] Univ Gavle, Dept Bldg Engn Energy Syst & Sustainabil Sci, Kungsbacksvagen 47, S-80176 Gavle, Sweden
关键词
CPC PVT collector; LCPVT; Transverse bifacial PVT receiver; Irradiation flux distribution; Performance evaluation; Ray-tracing; INCIDENCE ANGLE MODIFIER; TROUGH SOLAR COLLECTORS; THERMAL-SYSTEMS; SIMULATION; REFLECTORS; OPTIMIZATION; ARRAYS; YIELDS; CELLS;
D O I
10.1016/j.solener.2019.10.069
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
PVT collectors co-generate electricity and heat from the same gross area, thus achieving higher combined heat and electric yields. A comprehensive evaluation has been carried out on non-uniform solar irradiation profile distributions on four symmetric low concentration CPC PVT (LCPVT) solar collector design concepts. Additionally, an electrical and thermal performance evaluation of symmetric truncated LCPVT solar collectors based on a CPC reflector geometry with a central transverse bifacial PVT receiver has been carried out, through a numerical ray-tracing model software and a multi-paradigm numerical computing environment software. A simplified thermal (quasi-dynamic testing method for liquid heating collectors described in the international standard for solar thermal collectors ISO 9806:2017) and electrical performance models were employed to evaluate the LCPVT design concepts. The evaluation was carried out for heating Domestic Hot Water (DHW) for a Single Family House (SFH) in Fayoum (Egypt), where energy yields between 351 and 391 kWh/m(2)/year have been achieved. The non-uniform solar irradiation assessment showed that the PV cells are exposed to high levels of radiation due to the specific reflector geometry. Furthermore, the study showed that the CPC geometries are very sensitive to the shading effect, as partial shadowing is substantial for high incidence angles.
引用
收藏
页码:696 / 708
页数:13
相关论文
共 48 条
[1]   Evaluation of CPC-collector designs for stand-alone, roof- or wall installation [J].
Adsten, M ;
Helgesson, A ;
Karlsson, B .
SOLAR ENERGY, 2005, 79 (06) :638-647
[2]   Performance monitoring and modeling of an uncovered photovoltaic-thermal (PVT) water collector [J].
Aste, Niccolo ;
Del Pero, Claudio ;
Leonforte, Fabrizio ;
Manfren, Massimiliano .
SOLAR ENERGY, 2016, 135 :551-568
[3]   PV technologies performance comparison in temperate climates [J].
Aste, Niccolo ;
Del Pero, Claudio ;
Leonforte, Fabrizio .
SOLAR ENERGY, 2014, 109 :1-10
[4]  
Blanco M.J., 2009, P SOLARPACES 2009 IN, VVolume 1, P2009
[5]  
Blanco MJ, 2005, Proceedings of the ASME Computers and Information in Engineering Division, P157
[6]  
Brogren M., 2004, Optical efficiency of low-concentrating solar energy systems with parabolic reflectors"
[7]   Electrical and thermal performance evaluation of symmetric truncated C-PVT trough solar collectors with vertical bifacial receivers [J].
Cabral, Diogo ;
Karlsson, Bjorn O. .
SOLAR ENERGY, 2018, 174 :683-690
[8]   TRUNCATION OF CPC SOLAR COLLECTORS AND ITS EFFECT ON ENERGY COLLECTION [J].
CARVALHO, MJ ;
COLLARESPEREIRA, M ;
GORDON, JM ;
RABL, A .
SOLAR ENERGY, 1985, 35 (05) :393-399
[9]   Comparative and sensitive analysis for parabolic trough solar collectors with a detailed Monte Carlo ray-tracing optical model [J].
Cheng, Z. D. ;
He, Y. L. ;
Cui, F. Q. ;
Du, B. C. ;
Zheng, Z. J. ;
Xu, Y. .
APPLIED ENERGY, 2014, 115 :559-572
[10]   Numerical simulation of a parabolic trough solar collector with nonuniform solar flux conditions by coupling FVM and MCRT method [J].
Cheng, Z. D. ;
He, Y. L. ;
Cui, F. Q. ;
Xu, R. J. ;
Tao, Y. B. .
SOLAR ENERGY, 2012, 86 (06) :1770-1784