Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis

被引:17
作者
Ercal, Pinar [1 ]
Taysi, Aysegul Erten [1 ]
Ayvalioglu, Demet Cagil [2 ]
Eren, Meltem Mert [3 ]
Sismanoglu, Soner [3 ]
机构
[1] Altinbas Univ, Fac Dent, Dept Oral Surg, Incirli Cd 11, TR-34147 Istanbul, Turkey
[2] Altinbas Univ, Fac Dent, Dept Prosthet Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
[3] Altinbas Univ, Fac Dent, Dept Restorat Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
关键词
Dental implants; Implant prosthesis; Crown restoration; Bone resorption; Finite element analysis; SHORT DENTAL IMPLANTS; CROWN/IMPLANT RATIO; SURROUNDING BONE; LESS-THAN-10; MM; ORAL IMPLANTS; ZIRCONIA; HEIGHT; FORCES; METAANALYSIS; SYSTEMS;
D O I
10.1007/s11517-021-02342-w
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this study was to determine the effects of prosthetic materials and crown/implant (C/I) ratio on short implants with a marginal bone resorption. Three-dimensional finite element analysis was used to simulate stress distribution under static loading in non-resorption and resorption scenarios (3-mm vertical bone loss) in implants restored with single crowns and C/I ratios of 1:1, 1.5:1, and 2:1 were evaluated. Different crown materials were used: porcelain-fused to metal, porcelain-fused to zirconia, monolithic zirconia, and zirconia-based crown veneered with indirect composite resin. The C/I ratio, the peri-implant bone resorption, and the loading conditions were the key factors affecting the generated stress in short implants. In non-resorption models, von Mises stress ranged between 50 and 105 MPa whereas in resorption models, the values ranged from 168 to 322 MPa, both increasing with the higher C/I ratio under oblique forces. Under axial loading, the C/I ratio did not influence the stress values as the presence of resorption was the only parameter increasing, 57 MPa for the non-resorption models and 101 MPa for the resorption models, respectively. Preference of a prosthetic material was ineffective on the distribution of stress in the bone and implant structure under static loading in any models. The peri-implant bone resorption and a higher C/I ratio in short implants increase the stress values under both axial and oblique forces, whereas the crown material does not influence stress distribution in the surrounding bone and implant structure.
引用
收藏
页码:813 / 824
页数:12
相关论文
共 50 条
  • [41] Influence of the implant prosthetic restorations components on the stress values and distribution in surrounding bone- a finite element analysis
    Tanasescu, L. A.
    Farcasiu, A. T.
    Farcasiu, C.
    Imre, M.
    Tierean, M. H.
    Munteanu, D.
    Andrei, O. C.
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [42] Consequences of Peri-Implant Bone Loss in the Occlusal Load Transfer to the Supporting Bone in terms of Magnitude of Stress, Strain, and Stress Distribution: A Finite Element Analysis
    Perez-Pevida, Esteban
    Chavarri-Prado, David
    Dieguez-Pereira, Markel
    Estrada-Martinez, Alejandro
    Montalban-Vadillo, Oier
    Jimenez-Garrudo, Antonio
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [43] Influence of Prosthetic Parameters on Peri-Implant Bone Resorption in the First Year of Loading: A Multi-Factorial Analysis
    Hof, Markus
    Pommer, Bernhard
    Zukic, Nizama
    Vasak, Christoph
    Lorenzoni, Martin
    Zechner, Werner
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E183 - E191
  • [44] Influence of Implant/Abutment Connection on Stress Distribution to Implant-Surrounding Bone: A Finite Element Analysis
    Hanaoka, Marcia
    Alexandre Gehrke, Sergio
    Mardegan, Fabio
    Gennari, Cesar Roberto
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (07): : 565 - 571
  • [45] Three-dimensional finite element analysis of stress distribution in peri-implant bone with relined dentures and different heights of healing caps
    dos Santos, M. B. F.
    da Silva Neto, J. P.
    Consani, R. L. X.
    Mesquita, M. F.
    JOURNAL OF ORAL REHABILITATION, 2011, 38 (09) : 691 - 696
  • [46] Peri-implant bone tissue strains in cases of dehiscence: a finite element study
    Van Oosterwyck, H
    Duyck, J
    Vander Sloten, J
    Van der Perre, G
    Naert, I
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 327 - 333
  • [47] Effect of Crown to Implant Ratio and Implant Dimensions on Periimplant Stress of Splinted Implant-Supported Crowns: A Finite Element Analysis
    Bayraktar, Mehmet
    Gultekin, B. Alper
    Yalcin, Serdar
    Mijiritsky, Eitan
    IMPLANT DENTISTRY, 2013, 22 (04) : 406 - 413
  • [48] Finite element analysis of peri-implant bone stresses induced by root contact of orthodontic microimplant
    Yu, Won-Jae
    Kim, Mi-Ryoung
    Park, Hyo-Sang
    Kyung, Hee-Moon
    Kwon, Oh-Won
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (01) : 6 - 15
  • [49] Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Suriyawanakul, Jarupol
    Li, Qing
    Sasaki, Keiichi
    Yoda, Nobuhiro
    Rungsiyakull, Pimduen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (08): : 815 - 823
  • [50] Influence of Crown-to-Implant Ratio on Long Term Marginal Bone Loss Around Short Implants
    Di Fiore, Adolfo
    Vigolo, Paolo
    Sivolella, Stefano
    Cavallin, Francesco
    Katsoulis, Joannis
    Monaco, Carlo
    Stellini, Edoardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 992 - 998