Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis

被引:17
|
作者
Ercal, Pinar [1 ]
Taysi, Aysegul Erten [1 ]
Ayvalioglu, Demet Cagil [2 ]
Eren, Meltem Mert [3 ]
Sismanoglu, Soner [3 ]
机构
[1] Altinbas Univ, Fac Dent, Dept Oral Surg, Incirli Cd 11, TR-34147 Istanbul, Turkey
[2] Altinbas Univ, Fac Dent, Dept Prosthet Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
[3] Altinbas Univ, Fac Dent, Dept Restorat Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
关键词
Dental implants; Implant prosthesis; Crown restoration; Bone resorption; Finite element analysis; SHORT DENTAL IMPLANTS; CROWN/IMPLANT RATIO; SURROUNDING BONE; LESS-THAN-10; MM; ORAL IMPLANTS; ZIRCONIA; HEIGHT; FORCES; METAANALYSIS; SYSTEMS;
D O I
10.1007/s11517-021-02342-w
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this study was to determine the effects of prosthetic materials and crown/implant (C/I) ratio on short implants with a marginal bone resorption. Three-dimensional finite element analysis was used to simulate stress distribution under static loading in non-resorption and resorption scenarios (3-mm vertical bone loss) in implants restored with single crowns and C/I ratios of 1:1, 1.5:1, and 2:1 were evaluated. Different crown materials were used: porcelain-fused to metal, porcelain-fused to zirconia, monolithic zirconia, and zirconia-based crown veneered with indirect composite resin. The C/I ratio, the peri-implant bone resorption, and the loading conditions were the key factors affecting the generated stress in short implants. In non-resorption models, von Mises stress ranged between 50 and 105 MPa whereas in resorption models, the values ranged from 168 to 322 MPa, both increasing with the higher C/I ratio under oblique forces. Under axial loading, the C/I ratio did not influence the stress values as the presence of resorption was the only parameter increasing, 57 MPa for the non-resorption models and 101 MPa for the resorption models, respectively. Preference of a prosthetic material was ineffective on the distribution of stress in the bone and implant structure under static loading in any models. The peri-implant bone resorption and a higher C/I ratio in short implants increase the stress values under both axial and oblique forces, whereas the crown material does not influence stress distribution in the surrounding bone and implant structure.
引用
收藏
页码:813 / 824
页数:12
相关论文
共 50 条
  • [1] Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis
    Pinar Ercal
    Aysegul Erten Taysi
    Demet Cagil Ayvalioglu
    Meltem Mert Eren
    Soner Sismanoglu
    Medical & Biological Engineering & Computing, 2021, 59 : 813 - 824
  • [2] Effect of crown-to-implant ratio on peri-implant stress: A finite element analysis
    Verri, Fellippo Ramos
    de Souza Batista, Victor Eduardo
    Santiago, Joel Ferreira, Jr.
    de Faria Almeida, Daniel Augusto
    Pellizzer, Eduardo Piza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 : 234 - 240
  • [3] The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis
    Jin, Zhi-Heng
    Peng, Meng-Dong
    Li, Qing
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (04) : 466 - 471
  • [4] Effect of Integration Patterns Around Implant Neck on Stress Distribution in Peri-Implant Bone: A Finite Element Analysis
    Han, Jingyun
    Sun, Yuchun
    Wang, Chao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 549 - 558
  • [5] The effects of different grading approaches in additively manufactured dental implants on peri-implant bone stress: A finite element analysis
    Akbas, Osman
    Greuling, Andreas
    Stiesch, Meike
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 154
  • [6] Finite element analysis of mini implant biomechanics on peri-implant bone
    Hisam, Muhammad Juzaili
    Zaman, Izzuddin
    Shari, Safian
    Kurniawan, Denni
    Nor, Fethma M.
    DIGITAL MANUFACTURING TRANSFORMING INDUSTRY TOWARDS SUSTAINABLE GROWTH, 2019, 30 : 308 - 314
  • [7] Preventing stress singularities in peri-implant bone - a finite element analysis using a graded bone model
    Roffmann, Oliver
    Stiesch, Meike
    Greuling, Andreas
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (05) : 547 - 557
  • [8] Effect of implant systems in differing bone densities on peri-implant bone stress: A 3 dimensional finite element analysis
    Sahi, Aoujashwie
    Gali, Sivaranjani
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 1300 - 1307
  • [9] Impact of Prosthetic Material and Restoration Type on Peri-Implant Bone Resorption: A Retrospective Analysis in a Romanian Sample
    Sabau, Denisa Tabita
    Juncar, Raluca Iulia
    Moca, Abel Emanuel
    Bota, Teofana
    Moca, Rahela Tabita
    Juncar, Mihai
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [10] Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis
    Zhang, Wen-tao
    Cheng, Kang-jie
    Liu, Yun-feng
    Wang, Russell
    Chen, Yun-fang
    Ding, Yu-de
    Yang, Fan
    Wang, Lin-hong
    BMC ORAL HEALTH, 2022, 22 (01)