Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis

被引:24
作者
Ercal, Pinar [1 ]
Taysi, Aysegul Erten [1 ]
Ayvalioglu, Demet Cagil [2 ]
Eren, Meltem Mert [3 ]
Sismanoglu, Soner [3 ]
机构
[1] Altinbas Univ, Fac Dent, Dept Oral Surg, Incirli Cd 11, TR-34147 Istanbul, Turkey
[2] Altinbas Univ, Fac Dent, Dept Prosthet Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
[3] Altinbas Univ, Fac Dent, Dept Restorat Dent, Incirli Cd 11, TR-34147 Istanbul, Turkey
关键词
Dental implants; Implant prosthesis; Crown restoration; Bone resorption; Finite element analysis; SHORT DENTAL IMPLANTS; CROWN/IMPLANT RATIO; SURROUNDING BONE; LESS-THAN-10; MM; ORAL IMPLANTS; HEIGHT; ZIRCONIA; FORCES; OVERDENTURES; METAANALYSIS;
D O I
10.1007/s11517-021-02342-w
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this study was to determine the effects of prosthetic materials and crown/implant (C/I) ratio on short implants with a marginal bone resorption. Three-dimensional finite element analysis was used to simulate stress distribution under static loading in non-resorption and resorption scenarios (3-mm vertical bone loss) in implants restored with single crowns and C/I ratios of 1:1, 1.5:1, and 2:1 were evaluated. Different crown materials were used: porcelain-fused to metal, porcelain-fused to zirconia, monolithic zirconia, and zirconia-based crown veneered with indirect composite resin. The C/I ratio, the peri-implant bone resorption, and the loading conditions were the key factors affecting the generated stress in short implants. In non-resorption models, von Mises stress ranged between 50 and 105 MPa whereas in resorption models, the values ranged from 168 to 322 MPa, both increasing with the higher C/I ratio under oblique forces. Under axial loading, the C/I ratio did not influence the stress values as the presence of resorption was the only parameter increasing, 57 MPa for the non-resorption models and 101 MPa for the resorption models, respectively. Preference of a prosthetic material was ineffective on the distribution of stress in the bone and implant structure under static loading in any models. The peri-implant bone resorption and a higher C/I ratio in short implants increase the stress values under both axial and oblique forces, whereas the crown material does not influence stress distribution in the surrounding bone and implant structure.
引用
收藏
页码:813 / 824
页数:12
相关论文
共 69 条
[1]   Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism [J].
Akça, K ;
Iplikçioglu, H .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (04) :350-356
[2]   Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis [J].
Akca, Kivanc ;
Cehreli, Murat Cavit .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (07) :527-535
[3]   Primary and Secondary Stability of Single Short Implants [J].
Alonso, Fernando R. ;
Triches, Diego F. ;
Mezzomo, Luis A. M. ;
Teixeira, Eduardo R. ;
Shinkai, Rosemary S. A. .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (06) :E548-E551
[4]   Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study [J].
Alvarez-Arenal, Angel ;
Gonzalez-Gonzalez, Ignacio ;
deLlanos-Lanchares, Hector ;
Martin-Fernandez, Elena ;
Brizuela-Velasco, Aritza ;
Ellacuria-Echebarria, Joseba .
JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (05) :371-380
[5]   Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog [J].
Barbier, L ;
Vander Sloten, J ;
Krzesinski, G ;
Schepers, E ;
Van Der Perre, G .
JOURNAL OF ORAL REHABILITATION, 1998, 25 (11) :847-858
[6]   Effect of Crown to Implant Ratio and Implant Dimensions on Periimplant Stress of Splinted Implant-Supported Crowns: A Finite Element Analysis [J].
Bayraktar, Mehmet ;
Gultekin, B. Alper ;
Yalcin, Serdar ;
Mijiritsky, Eitan .
IMPLANT DENTISTRY, 2013, 22 (04) :406-413
[7]   Crown-to-Implant Ratios of Short-Length Implants [J].
Birdi, Hardeep ;
Schulte, John ;
Kovacs, Alejandro ;
Weed, Meghan ;
Chuang, Sung-Kiang .
JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (06) :425-433
[8]   Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis [J].
Borges Radaelli, Manuel Tomas ;
Idogava, Henrique Takashi ;
Spazzin, Aloisio Oro ;
Noritomi, Pedro Yoshito ;
Boscato, Noeli .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04) :565-572
[9]   Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis [J].
Bulaqi, Haddad Arabi ;
Mashhadi, Mahmoud Mousavi ;
Safari, Hamed ;
Samandari, Mohammad Mahdi ;
Geramipanah, Farideh .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) :548-557
[10]   Impact of excessive occlusal load on successfully-osseointegrated dental implants: a literature review [J].
Chang, Michael ;
Chronopoulos, Vasileios ;
Mattheos, Nikos .
JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2013, 4 (03) :142-150