In vivo skin moisturizing measurement by high-resolution 3 Tesla magnetic resonance imaging

被引:5
|
作者
Mesrar, J. [1 ]
Ognard, J. [1 ]
Garetier, M. [2 ]
Chechin, D. [3 ]
Misery, L. [4 ]
Ben Salem, D. [1 ]
机构
[1] Univ Hosp Brest, LATIM INSERM UMR 1101, Dept Neuroradiol, Brest, France
[2] Mil Teaching Hosp, Dept Radiol, Brest, France
[3] Philips Healthcare France, Suresnes, France
[4] LNB EA4685, Dept Dermatol, Brest, France
关键词
skin imaging; 3; Tesla; microscopic coil; moisturizing measurement; T2; mapping; SPATIAL-RESOLUTION; RELAXATION-TIMES; STRATUM-CORNEUM; NMR MICROSCOPY; MRI; VISUALIZATION; TISSUE; LAYERS;
D O I
10.1111/srt.12333
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: Magnetic resonance imaging (MRI) is rarely used for the exploration of skin, even if studies have validated both feasibility of skin MRI and its interest for anatomical, physiological, and biochemical study of the skin. The purpose of this study is to explore moisturizing of the different skin layers using 3-T scan. Methods: An MRI of the heel's skin was performed using a 23 mm coil diameter on a 3T scan with a FFE (Fast Field Echo) 3D T1-weighted sequence and a TSE (Turbo Spin Echo) calculation T2-weighted sequence (pixels size of respectively 60 and 70 mu m). This study was conducted on 35 healthy volunteers, who were scanned before applying moisturizer topic and 1 h after applying it. Region of interest in the stratum corneum, the epidermis and the dermis were generated on the T2 mapping. The thickness of each layer was measured. The T1 sequence allowed accurate cross-examination repositioning to ensure the comparability of the measurements. Results: Among the 35 cases, two were excluded from the analysis because of movement artifacts. Measurements before and after moisturizer topic application displayed a T2 increase of 48.94% (P < 0.0001) in the stratum corneum and of 5.45% (P < 0.0001) in the epidermis yet without significant difference in the dermis. There was no significant link between the thickness of the stratum corneum and the T2 increase. However, there was a strong correlation between the thickness of the stratum corneum and the thickness of the epidermis (P < 0.001; rho=0.72). Conclusion: High-resolution MRI allows fine exploration of anatomical and physiological properties of the skin and can further be used to extend the studies of skin hydration.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [41] Lensless high-resolution photoacoustic imaging scanner for in vivo skin imaging
    Ida, Taiichiro
    Iwazaki, Hideaki
    Omuro, Toshiyuki
    Kawaguchi, Yasushi
    Tsunoi, Yasuyuki
    Kawauchi, Satoko
    Sato, Shunichi
    OPTICAL REVIEW, 2018, 25 (01) : 33 - 39
  • [42] Lensless high-resolution photoacoustic imaging scanner for in vivo skin imaging
    Taiichiro Ida
    Hideaki Iwazaki
    Toshiyuki Omuro
    Yasushi Kawaguchi
    Yasuyuki Tsunoi
    Satoko Kawauchi
    Shunichi Sato
    Optical Review, 2018, 25 : 33 - 39
  • [43] High-resolution magnetic resonance imaging of recurrent pneumoparotitis
    Sittel, C
    Jungehülsing, M
    Fischbach, R
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (08): : 816 - 818
  • [44] High-resolution Magnetic Resonance Imaging of Moyamoya Disease
    Yu Le-Bao
    Zhang Qian
    Shi Zhi-Yong
    Wang Ming-Qiu
    Zhang Dong
    中华医学杂志英文版, 2015, 128 (23) : 3231 - 3237
  • [45] High-resolution magnetic resonance spectroscopic imaging in MS
    Bogner, W.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 82 - 82
  • [46] High-resolution Magnetic Resonance Imaging of Moyamoya Disease
    Yu, Le-Bao
    Zhang, Qian
    Shi, Zhi-Yong
    Wang, Ming-Qiu
    Zhang, Dong
    CHINESE MEDICAL JOURNAL, 2015, 128 (23) : 3231 - 3237
  • [47] High-resolution magnetic resonance imaging of human cochlea
    Silver, RD
    Djalilian, HR
    Levine, SC
    Rimell, FL
    LARYNGOSCOPE, 2002, 112 (10): : 1737 - 1741
  • [48] EX-VIVO EXPERIMENTAL 7 TESLA HIGH RESOLUTION MAGNETIC RESONANCE IMAGING - OF LOCALIZED PROSTATE CANCER
    Durand, Matthieu
    Bessede, Thomas
    Treacy, Patrick-Julien
    Bentellis, Imad
    Corcuera-Solano, Idoia
    Taouli, Bachir
    Rastinehad, Ardeshir
    Tang, Cheuck Ying
    Wang, Victoria
    Reddy, Balaji
    Raffaelli, Charles
    Fromont, Gaelle
    Puech, Philippe
    Kaines, Kenneth
    Tewari, Ashutosh K.
    Villers, Arnaud
    JOURNAL OF UROLOGY, 2020, 203 : E1106 - E1107
  • [49] Measurement of fluid flow in pipe and porous media by high-resolution magnetic resonance imaging
    Lan-lan Jiang
    Yong-chen Song
    Yu Liu
    Bin-lin Dou
    Ning-jun Zhu
    Jia-fei Zhao
    Abudula Buliti
    China Ocean Engineering, 2012, 26 : 317 - 328
  • [50] Measurement of Fluid Flow in Pipe and Porous Media by High-Resolution Magnetic Resonance Imaging
    蒋兰兰
    宋永臣
    刘瑜
    豆斌林
    朱宁军
    赵佳飞
    BULITI Abudul
    China Ocean Engineering, 2012, 26 (02) : 317 - 328