In vivo skin moisturizing measurement by high-resolution 3 Tesla magnetic resonance imaging

被引:5
|
作者
Mesrar, J. [1 ]
Ognard, J. [1 ]
Garetier, M. [2 ]
Chechin, D. [3 ]
Misery, L. [4 ]
Ben Salem, D. [1 ]
机构
[1] Univ Hosp Brest, LATIM INSERM UMR 1101, Dept Neuroradiol, Brest, France
[2] Mil Teaching Hosp, Dept Radiol, Brest, France
[3] Philips Healthcare France, Suresnes, France
[4] LNB EA4685, Dept Dermatol, Brest, France
关键词
skin imaging; 3; Tesla; microscopic coil; moisturizing measurement; T2; mapping; SPATIAL-RESOLUTION; RELAXATION-TIMES; STRATUM-CORNEUM; NMR MICROSCOPY; MRI; VISUALIZATION; TISSUE; LAYERS;
D O I
10.1111/srt.12333
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: Magnetic resonance imaging (MRI) is rarely used for the exploration of skin, even if studies have validated both feasibility of skin MRI and its interest for anatomical, physiological, and biochemical study of the skin. The purpose of this study is to explore moisturizing of the different skin layers using 3-T scan. Methods: An MRI of the heel's skin was performed using a 23 mm coil diameter on a 3T scan with a FFE (Fast Field Echo) 3D T1-weighted sequence and a TSE (Turbo Spin Echo) calculation T2-weighted sequence (pixels size of respectively 60 and 70 mu m). This study was conducted on 35 healthy volunteers, who were scanned before applying moisturizer topic and 1 h after applying it. Region of interest in the stratum corneum, the epidermis and the dermis were generated on the T2 mapping. The thickness of each layer was measured. The T1 sequence allowed accurate cross-examination repositioning to ensure the comparability of the measurements. Results: Among the 35 cases, two were excluded from the analysis because of movement artifacts. Measurements before and after moisturizer topic application displayed a T2 increase of 48.94% (P < 0.0001) in the stratum corneum and of 5.45% (P < 0.0001) in the epidermis yet without significant difference in the dermis. There was no significant link between the thickness of the stratum corneum and the T2 increase. However, there was a strong correlation between the thickness of the stratum corneum and the thickness of the epidermis (P < 0.001; rho=0.72). Conclusion: High-resolution MRI allows fine exploration of anatomical and physiological properties of the skin and can further be used to extend the studies of skin hydration.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 50 条
  • [31] Fetal magnetic resonance imaging at 3 Tesla - the European experience
    Colleran, Gabrielle C.
    Kyncl, Martin
    Garel, Catherine
    Cassart, Marie
    PEDIATRIC RADIOLOGY, 2022, 52 (05) : 959 - 970
  • [32] Image Restoration and Spatial Resolution in 7-Tesla Magnetic Resonance Imaging
    Lohmann, Gabriele
    Bohn, Stefan
    Mueller, Karsten
    Trampel, Robert
    Turner, Robert
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 15 - 22
  • [33] Anatomically Accurate, High-Resolution Modeling of the Human Index Finger Using In Vivo Magnetic Resonance Imaging
    Rogelj, Luka
    Dolenec, Rok
    Tomsic, Martina Vivoda
    Laistler, Elmar
    Simoncic, Urban
    Milanic, Matija
    Hren, Rok
    TOMOGRAPHY, 2022, 8 (05) : 2347 - 2359
  • [34] High-Resolution Magnetic Resonance Imaging of the Upper Eyelid: Correlation with the Position of the Skin Crease in the Upper Eyelid
    Galatoire, O.
    Touitou, V.
    Heran, F.
    Amar, N.
    Jacomet, P. V.
    Gheck, L.
    Berete-Coulibaly, R.
    Benchekroun, S.
    Morax, S.
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2007, 26 (03): : 165 - 171
  • [35] High-resolution In Vivo Manual Segmentation Protocol for Human Hippocampal Subfields Using 3T Magnetic Resonance Imaging
    Winterburn, Julie
    Pruessner, Jens C.
    Sofia, Chavez
    Schira, Mark M.
    Lobaugh, Nancy J.
    Voineskos, Aristotle N.
    Chakravarty, M. Mallar
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (105):
  • [36] In vivo high-resolution magnetic resonance elastography of the uterine corpus and cervix
    Jiang, Xuyuan
    Asbach, Patrick
    Streitberger, Kaspar-Josche
    Thomas, Anke
    Hamm, Bernd
    Braun, Juergen
    Sack, Ingolf
    Guo, Jing
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3025 - 3033
  • [37] Surface-based analysis methods for high-resolution functional magnetic resonance imaging
    Khan, Rez
    Zhang, Qin
    Darayan, Shayan
    Dhandapani, Sankari
    Katyal, Sucharit
    Greene, Clint
    Bajaj, Chandra
    Ress, David
    GRAPHICAL MODELS, 2011, 73 : 313 - 322
  • [38] Accuracy of High-Resolution In Vivo Micro Magnetic Resonance Imaging for Measurements of Microstructural and Mechanical Properties of Human Distal Tibial Bone
    Liu, X. Sherry
    Zhang, X. Henry
    Rajapakse, Chamith S.
    Wald, Michael J.
    Magland, Jeremy
    Sekhon, Kiranjit K.
    Adam, Mark F.
    Sajda, Paul
    Wehrli, Felix W.
    Guo, X. Edward
    JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (09) : 2039 - 2050
  • [39] Tractography of Porcine Meniscus Microstructure Using High-Resolution Diffusion Magnetic Resonance Imaging
    Shen, Jikai
    Zhao, Qi
    Qi, Yi
    Cofer, Gary
    Johnson, G. Allan
    Wang, Nian
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [40] In vivo prostate magnetic resonance imaging and magnetic resonance spectroscopy at 3 Tesla using a transceive pelvic phased array coil - Preliminary results
    Kim, HW
    Buckley, DL
    Peterson, DM
    Duensing, GR
    Caserta, J
    Fitzsimmons, J
    Blackband, SJ
    INVESTIGATIVE RADIOLOGY, 2003, 38 (07) : 443 - 451