Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

被引:31
作者
Lombardo, Giuseppe [1 ,2 ]
Serrao, Sebastiano [3 ]
Rosati, Marianna [3 ]
Lombardo, Marco [3 ]
机构
[1] CNR IPCF, Unit Support Cosenza, I-87036 Cosenza, Italy
[2] Vis Engn Italy Srl, I-00198 Rome, Italy
[3] Fdn GB Bietti, IRCCS, I-00198 Rome, Italy
关键词
COLLAGEN FIBRILS; BIOMECHANICAL PROPERTIES; MECHANICAL-PROPERTIES; ANTERIOR STROMA; CROSS-LINKING; BOVINE; ORGANIZATION; ELASTICITY; RABBIT; STRAIN;
D O I
10.1371/journal.pone.0112169
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To demonstrate a Scheimpflug-based imaging procedure for investigating the depth-and time-dependent strain response of the human cornea to inflation testing of whole eye globes. Methods: Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechanical tests in order to measure corneal strain resulting from application of cyclic (cyclic regimen) and constant (creep regimen) stress by changing the intra-ocular pressure (IOP) within physiological ranges (18-42 mmHg). Corneal shape changes were analyzed as a function of IOP and both corneal stress-strain curves and creep curves were generated. Results: The procedure was highly accurate and repeatable. Upon cyclic stress application, a biomechanical corneal elasticity gradient was found in the front-back direction. The average Young's modulus of the anterior cornea ranged between 2.28 +/- 0.87 MPa and 3.30 +/- 0.90 MPa in specimens with and without intact epithelium (P = 0.05) respectively. The Young's modulus of the posterior cornea was on average 0.21 +/- 0.09 MPa and 0.17 +/- 0.06 MPa (P>0.05) respectively. The time-dependent strain response of the cornea to creep testing was quantified by fitting data to a modified Zener model for extracting both the relaxation time and compliance function. Conclusion: Cyclic and creep mechanical tests are valuable for investigating the strain response of the intact human cornea within physiological IOP ranges, providing meaningful results that can be translated to clinic. The presence of epithelium influences the results of anterior corneal shape changes when monitoring deformation via Scheimpflug imaging in inflation experiments of whole eye globes.
引用
收藏
页数:10
相关论文
共 58 条
[1]  
[Anonymous], BIOMECHANICS MECH PR
[2]   Lamellar orientation in human cornea in relation to mechanical properties [J].
Boote, C ;
Dennis, S ;
Huang, YF ;
Quantock, AJ ;
Meek, KM .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) :1-6
[3]   Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications [J].
Boote, C ;
Dennis, S ;
Newton, RH ;
Puri, H ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) :2941-2948
[4]   Mechanical Characterization of Porcine Corneas [J].
Boschetti, F. ;
Triacca, V. ;
Spinelli, L. ;
Pandolfi, A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (03)
[5]   Stress-controlled viscoelastic tensile response of bovine cornea [J].
Boyce, B. L. ;
Jones, R. E. ;
Nguyen, T. D. ;
Grazier, J. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2367-2376
[6]   Full-field deformation of bovine cornea under constrained inflation conditions [J].
Boyce, Brad L. ;
Grazier, J. Mark ;
Jones, Reese E. ;
Nguyen, Thao D. .
BIOMATERIALS, 2008, 29 (28) :3896-3904
[7]   The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology [J].
Browning, AC ;
Bhan, A ;
Rotchford, AP ;
Shah, S ;
Dua, HS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (11) :1395-1399
[8]   Analysis of Corneal Stroma Organization With Wavefront Optimized Nonlinear Microscopy [J].
Bueno, Juan M. ;
Gualda, Emilio J. ;
Artal, Pablo .
CORNEA, 2011, 30 (06) :692-701
[9]   MATHEMATICAL-MODELS OF THE GENERAL CORNEAL SURFACE [J].
BUREK, H ;
DOUTHWAITE, WA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1993, 13 (01) :68-72
[10]  
CASTORO JA, 1988, INVEST OPHTH VIS SCI, V29, P963