Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods

被引:81
|
作者
Koobi, T
Kaukinen, S
Ahola, T
Turjanmaa, VMH
机构
[1] Tampere Univ Hosp, Dept Clin Physiol, FIN-33521 Tampere, Finland
[2] Tampere Univ Hosp, Dept Anaesthesia & Intens Care, Tampere, Finland
[3] Univ Tampere, Sch Med, Dept Clin Physiol, FIN-33101 Tampere, Finland
关键词
whole-body impedance cardiography; thermodilution; direct oxygen Fick; cardiac output; haemodynamics;
D O I
10.1007/s001340050469
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the reliability of whole-body impedance cardiography (ICG(WB)), with electrodes attached to wrists and ankles, in the measurement of cardiac output (GO) on the basis of simultaneous comparison with thermodilution (TD) and direct oxygen Fick (Fick) methods. Design: Prospective clinical study. Setting: A surgical intensive care unit at a university hospital. Patients: Thirty consecutive subjects undergoing a coronary artery bypass surgery were investigated preoperatively. Measurements: ICG(WB) derived CO was measured simultaneously with the TD and Pick methods to establish the biases and limits of agreement (LA) between the methods. Results: The results obtained by ICG, and the invasive methods showed good agreement. The bias and LA between COTD and COICG were 0.00 l/min; -1.37 and 1.37 l/ min, respectively, and were close to those obtained between COTD and COFICK, 0.32 l/min; 1.74 and -1.10 l/min. The bias and LA between the COFICK and COICG were -0.32 l/min; -2.24 and 1.60 l/min respectively. The repeatability value of consecutive single measurements for ICG(WB) (RVICG = 0.57 l/min) was much better than for the TD method (RVTD = 1.10 l/min). Conclusion: There was close agreement between the results of the three methods in the measurement of CO. In sedated preoperative patients the accuracy of ICG(WB) is within clinically acceptable limits and its repeatability is excellent. ICG(WB) provides a useful alternative to the TD and Fick methods in cases where the pressures supplied by the pulmonary artery catheter are not essential.
引用
收藏
页码:1132 / 1137
页数:6
相关论文
共 30 条
  • [21] Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: Comparison with thermodilution method
    Gujjar A.R.
    Muralidhar K.
    Banakal S.
    Gupta R.
    Sathyaprabha T.N.
    Jairaj P.S.
    Journal of Clinical Monitoring and Computing, 2008, 22 (03) : 175 - 180
  • [22] Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care
    Bataille, B.
    Bertuit, M.
    Mora, M.
    Mazerolles, M.
    Cocquet, P.
    Masson, B.
    Moussot, P. E.
    Ginot, J.
    Silva, S.
    Larche, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 879 - 886
  • [23] Non-invasive assessment of cardiac output during exercise in chronic obstructive pulmonary disease: comparison of the CO2-rebreathing method and electrical impedance cardiography
    Bogaard, HJ
    Hamersma, WBGJ
    Horsch, JLMI
    Woltjer, HH
    Postmus, PE
    deVries, PMJM
    PHYSIOLOGICAL MEASUREMENT, 1997, 18 (04) : 327 - 338
  • [24] A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors: Comparison with the continuous thermodilution method early cardiovascular monitors
    Ishihara H.
    Okawa H.
    Tanabe K.
    Tsubo T.
    Sugo Y.
    Akiyama T.
    Takeda S.
    Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 313 - 320
  • [25] Non-Invasive Measurement of Cardiac Output during Atrial Fibrillation: Comparison between Cardiac Magnetic Resonance Imaging and Inert Gas Rebreathing
    Saur, J.
    Trinkmann, F.
    Doesch, C.
    Weissmann, J.
    Hamm, K.
    Schoenberg, S. O.
    Borggrefe, M.
    Haghi, D.
    Kaden, J. J.
    CARDIOLOGY, 2010, 115 (03) : 212 - 216
  • [26] Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography
    Rauch, Ralf
    Welisch, Eva
    Lansdell, Nathan
    Burrill, Elizabeth
    Jones, Judy
    Robinson, Tracy
    Bock, Dirk
    Clarson, Cheril
    Filler, Guido
    Norozi, Kambiz
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (02) : 187 - 193
  • [27] Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography
    Ralf Rauch
    Eva Welisch
    Nathan Lansdell
    Elizabeth Burrill
    Judy Jones
    Tracy Robinson
    Dirk Bock
    Cheril Clarson
    Guido Filler
    Kambiz Norozi
    Journal of Clinical Monitoring and Computing, 2013, 27 : 187 - 193
  • [28] Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study
    Blohm, Martin Ernst
    Obrecht, Denise
    Hartwich, Jana
    Mueller, Goetz Christoph
    Kersten, Jan Felix
    Weil, Jochen
    Singer, Dominique
    CRITICAL CARE, 2014, 18 (06):
  • [29] Non-invasive in vivo measurement of cardiac output in C57BL/6 mice using high frequency transthoracic ultrasound: evaluation of gender and body weight effects
    Dominguez, Elisabet
    Ruberte, Jesus
    Rios, Jose
    Novellas, Rosa
    Montserrat Rivera del Alamo, Maria
    Navarro, Marc
    Espada, Yvonne
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (07) : 1237 - 1244
  • [30] Non-invasive in vivo measurement of cardiac output in C57BL/6 mice using high frequency transthoracic ultrasound: evaluation of gender and body weight effects
    Elisabet Domínguez
    Jesús Ruberte
    José Ríos
    Rosa Novellas
    Maria Montserrat Rivera del Alamo
    Marc Navarro
    Yvonne Espada
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1237 - 1244