Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods

被引:81
|
作者
Koobi, T
Kaukinen, S
Ahola, T
Turjanmaa, VMH
机构
[1] Tampere Univ Hosp, Dept Clin Physiol, FIN-33521 Tampere, Finland
[2] Tampere Univ Hosp, Dept Anaesthesia & Intens Care, Tampere, Finland
[3] Univ Tampere, Sch Med, Dept Clin Physiol, FIN-33101 Tampere, Finland
关键词
whole-body impedance cardiography; thermodilution; direct oxygen Fick; cardiac output; haemodynamics;
D O I
10.1007/s001340050469
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the reliability of whole-body impedance cardiography (ICG(WB)), with electrodes attached to wrists and ankles, in the measurement of cardiac output (GO) on the basis of simultaneous comparison with thermodilution (TD) and direct oxygen Fick (Fick) methods. Design: Prospective clinical study. Setting: A surgical intensive care unit at a university hospital. Patients: Thirty consecutive subjects undergoing a coronary artery bypass surgery were investigated preoperatively. Measurements: ICG(WB) derived CO was measured simultaneously with the TD and Pick methods to establish the biases and limits of agreement (LA) between the methods. Results: The results obtained by ICG, and the invasive methods showed good agreement. The bias and LA between COTD and COICG were 0.00 l/min; -1.37 and 1.37 l/ min, respectively, and were close to those obtained between COTD and COFICK, 0.32 l/min; 1.74 and -1.10 l/min. The bias and LA between the COFICK and COICG were -0.32 l/min; -2.24 and 1.60 l/min respectively. The repeatability value of consecutive single measurements for ICG(WB) (RVICG = 0.57 l/min) was much better than for the TD method (RVTD = 1.10 l/min). Conclusion: There was close agreement between the results of the three methods in the measurement of CO. In sedated preoperative patients the accuracy of ICG(WB) is within clinically acceptable limits and its repeatability is excellent. ICG(WB) provides a useful alternative to the TD and Fick methods in cases where the pressures supplied by the pulmonary artery catheter are not essential.
引用
收藏
页码:1132 / 1137
页数:6
相关论文
共 30 条
  • [1] Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    T. Kööbi
    S. Kaukinen
    T. Ahola
    V. M. H. Turjanmaa
    Intensive Care Medicine, 1997, 23 : 1132 - 1137
  • [2] Whole-body impedance cardiography in the measurement of cardiac output
    Koobi, T
    Kaukinen, S
    Turjanmaa, VMH
    Uusitalo, AJ
    CRITICAL CARE MEDICINE, 1997, 25 (05) : 779 - 785
  • [3] Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography
    Kaukinen, S
    Kööbi, T
    Bi, YB
    Turjanmaa, VMH
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 199 - 203
  • [4] Standardization of non-invasive impedance cardiography for assessment of stroke volume: Comparison with thermodilution
    Woltjer, HH
    Bogaard, HJ
    Scheffer, GJ
    vanderSpoel, HI
    Huybregts, MAJM
    deVries, PMJM
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (06) : 748 - 752
  • [5] Noninvasive whole-body electrical bioimpedance cardiac output and invasive thermodilution cardiac output in high-risk surgical patients
    Imhoff, M
    Lehner, JH
    Löhlein, D
    CRITICAL CARE MEDICINE, 2000, 28 (08) : 2812 - 2818
  • [6] A comparison of the Finapres and impedance cardiography for non-invasive estimation of cardiac output during mental stress
    Wilhelm, FH
    Mauss, IB
    Pastuszek, DS
    Gross, JJ
    PSYCHOPHYSIOLOGY, 2003, 40 : S91 - S91
  • [7] A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method
    Anne Charloux
    Evelyne Lonsdorfer-Wolf
    Ruddy Richard
    Eliane Lampert
    Monique Oswald-Mammosser
    Bertrand Mettauer
    Bernard Geny
    Jean Lonsdorfer
    European Journal of Applied Physiology, 2000, 82 : 313 - 320
  • [8] A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the "direct" Fick method
    Charloux, A
    Lonsdorfer-Wolf, E
    Richard, R
    Lampert, E
    Oswald-Mammosser, M
    Mettauer, B
    Geny, B
    Lonsdorfer, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 82 (04) : 313 - 320
  • [9] The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: A review
    Newman, DG
    Callister, R
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1999, 70 (08): : 780 - 789
  • [10] COMPARISON OF CARDIAC-OUTPUT MEASUREMENT TECHNIQUES - THERMODILUTION, DOPPLER, CO2-REBREATHING AND THE DIRECT FICK METHOD
    ESPERSEN, K
    JENSEN, EW
    ROSENBORG, D
    THOMSEN, JK
    ELIASEN, K
    OLSEN, NV
    KANSTRUP, IL
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (02) : 245 - 251