Advanced flow-through external pressure-balanced reference electrode for potentiometric and pH studies in high temperature aqueous solutions

被引:26
作者
Lvov, SN [1 ]
Gao, H [1 ]
Macdonald, DD [1 ]
机构
[1] Penn State Univ, Ctr Adv Mat, University Pk, PA 16802 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1998年 / 443卷 / 02期
关键词
flow-through external pressure-balanced reference electrode (FTEPBRE); potentiometric and pH measurements in high-temperature high-pressure aqueous solutions;
D O I
10.1016/S0022-0728(97)00530-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-through external pressure-balanced reference electrode (FTEPBRE) has been developed for potentiometric and pH measurements in high temperature aqueous solutions. The unique feature of this advanced FTEPBRE is that the reference solution flows through the electrode so that the concentration of solution across the thermal liquid junction is well defined. Because the electrolyte concentration profile in the reference electrode is maintained constant, uncertainty in the thermal liquid junction potential (TLJP) can be eliminated at a given temperature and pressure. We have employed the silver/silver chloride/platinum/hydrogen non-isothermal electrochemical system for potentiometric measurements of potentials between HCl(aq) solutions of 0.01 and 0.001 mol kg(-1) at temperatures up to 633 K and at pressures of 275 and 338 bar. The results of the measurements have been compared with calculations made using the available thermodynamic data, and good agreement, within +/-3 to 10 mV, between the calculated and the measured potentials is obtained. We concluded that the advanced reference electrode can be sed to make accurate potentiometric measurements (within a few mV) in aqueous systems over wide ranges of temperatures and pressures. Also we demonstrated an ability of the thermocell to measure pH with high accuracy of +/- 0.04 to 0.09 over wide ranges of temperature and pressure. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 27 条
[1]  
BOURCIER WL, 1987, HYDROTHERMAL EXPT TE, P157
[2]   DEFINITION OF PH SCALES, STANDARD REFERENCE VALUES, MEASUREMENT OF PH AND RELATED TERMINOLOGY - (RECOMMENDATIONS 1984) [J].
COVINGTON, AK ;
BATES, RG ;
DURST, RA .
PURE AND APPLIED CHEMISTRY, 1985, 57 (03) :531-542
[3]   Direct pH measurement of NaCl-bearing fluid with an in situ sensor at 400 degrees C and 40 megapascals [J].
Ding, K ;
Seyfried, WE .
SCIENCE, 1996, 272 (5268) :1634-1636
[4]   IN-SITU MEASUREMENT OF DISSOLVED H-2 IN AQUEOUS FLUID AT ELEVATED-TEMPERATURES AND PRESSURES [J].
DING, K ;
SEYFRIED, WE .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1995, 59 (22) :4769-4773
[5]   Gold as a hydrogen sensing electrode for in situ measurement of dissolved H-2 in supercritical aqueous fluid [J].
Ding, K ;
Seyfried, WE .
JOURNAL OF SOLUTION CHEMISTRY, 1996, 25 (05) :421-433
[6]   The measurement of Henry's constant for hydrogen in high subcritical and supercritical aqueous systems [J].
Eklund, K ;
Lvov, SN ;
Macdonald, DD .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 437 (1-2) :99-110
[7]  
FRANCK EU, 1956, Z PHYS CHEM, V8, P192
[8]  
Haase R., 1969, Thermodynamics of Irreversible Processes
[9]  
Henderson P, 1907, Z PHYS CHEM-STOCH VE, V59, P118
[10]   THE VIABILITY OF PH MEASUREMENTS IN SUPERCRITICAL AQUEOUS SYSTEMS [J].
HETTIARACHCHI, S ;
MAKELA, K ;
SONG, H ;
MACDONALD, DD .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1992, 139 (01) :L3-L4