This paper presents an experimental validation of, phase-lock loop less modified control strategy for single-phase shunt active power filter (APF) to compensate current harmonics and reactive power in single-phase distribution system under distorted supply voltage. The control technique is divided into two parts: first associated with selected frequency signal extraction by using Hilbert transform-based adaptive tuned filter from distorted supply voltage followed by reference current signal generation using DC-link energy balance method. Second deals with an improved pulse width modulation technique which reduces switching ripple and switching frequency for voltage source inverter used as a shunt APF. The overall control scheme is simulated using MATLAB/Simulink environment in the steady state and transient condition of the load. A detailed hardware design and other parameters of proposed system have been presented. A laboratory prototype has been developed using dSPACE DS1104 controller card having TMS320F240 as a slave DSP to verify the simulation results. Simulated and experimental results show that the proposed control technique gives a flexible and fast dynamic response in single-phase distribution system. The harmonic spectral performance of the proposed technique is as per the recommendation of IEEE-519 standards.
引用
收藏
页码:333 / 353
页数:21
相关论文
共 26 条
[1]   New digital reference current generation for shunt active power filter under distorted voltage conditions [J].
Abdusalam, Mohamed ;
Poure, Philippe ;
Karimi, Shahram ;
Saadate, Shahrokh .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (05) :759-765
[2]   Active harmonic filters [J].
Akagi, H .
PROCEEDINGS OF THE IEEE, 2005, 93 (12) :2128-2141
[3]  
Akagi H., 2007, INSTANTANEOUS POWER, P19
[4]   Harmonic computation technique suitable for active power filters [J].
Alejandro Gonzalez, Sergio ;
Garcia-Retegui, Rogelio ;
Benedetti, Mario .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (05) :2791-2796
[5]  
Alexander D.P., 1999, HDB FORMULAS TABLES, P295
[6]  
[Anonymous], 1992, 519 IEEE, P1
[7]   Consequences of poor power quality - An overview [J].
Bhattacharyya, S. ;
Myrzik, J. M. A. ;
Kling, W. L. .
2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, :651-656
[8]   Improved harmonic suppression efficiency of single-phase APFs in distorted distribution systems [J].
Biricik, Samet ;
Redif, Soydan ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
INTERNATIONAL JOURNAL OF ELECTRONICS, 2016, 103 (02) :232-246
[9]  
Bollen M.H., 1999, UNDERSTANDING POWER, P1
[10]   A novel approach to the design of a shunt active filter for an unbalanced three-phase four-wire system under nonsinusoidal conditions [J].
Chen, CC ;
Hsu, YY .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) :1258-1264