Performance of Hepatitis C virus (HCV) antibody test systems in relation to HCV-RNA detection in the diagnosis of HCV infection

被引:0
作者
Krarup, HB [1 ]
Jacobsen, SEH
Varming, K
Drewes, AM
Madsen, PH
机构
[1] Aalborg Hosp, Dept Clin Chem, DK-9000 Aalborg, Denmark
[2] Aalborg Hosp, Dept Med Gastroenterol, DK-9000 Aalborg, Denmark
[3] Aalborg Hosp, Dept Clin Immunol, DK-9000 Aalborg, Denmark
[4] Aalborg Hosp, Blood Bank, DK-9000 Aalborg, Denmark
来源
DANISH MEDICAL BULLETIN | 1998年 / 45卷 / 01期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hepatitis C virus antibody (anti-HCV) test systems for screening and conformation of blood donations have proved their value. The systems were later adopted for diagnosing patients suspected of hepatitis C. Objectives: 1) to study the clinical value of the recombinant immunoblot assay (RIBA) in routine diagnostics of patients suspected of HCV infection using HCV-PCR as the most definitive test and 2) to compare the performance of RIBA-2 with RIBA-3. Materials: From May 1991 to August 1996 more than 4300 patients were tested for anti-HCV. All anti-HCV (EIA) positive patients were tested with RIBA-2 or RIBA-3 and HCV-PCR. Results: We found no difference in the overall performance of RIBA-2 compared to RIBA-3. There was a tendency to fewer indeterminate results using RIBA-3 compared to RIBA-2 (5% vs. 9%), but this was not statistically significant. The NS5 band in RIBA-3 did not improve sensitivity or predictive value. Of RIBA-2 and RIBA-3 positive patients, 71% and 66% respectively were found to be HCV-RNA positive. Two samples that were negative using RIBA were HCV-RNA positive. Conclusion: RIBA testing in anti-HCV (EIA) positive patients added no clinically useful information to the screening results. We have therefore changed the diagnostic strategy so that all anti-HCV (EIA) positive patients are tested for HCV-RNA.
引用
收藏
页码:89 / 91
页数:3
相关论文
共 10 条
[1]   ENHANCED DETECTION OF ANTIBODIES TO HEPATITIS-C VIRUS BY USE OF A 3RD-GENERATION RECOMBINANT IMMUNOBLOT ASSAY [J].
BUFFET, C ;
CHARNAUX, N ;
LAURENTPUIG, P ;
CHOPINEAU, S ;
QUICHON, JP ;
BRIANTAIS, MJ ;
DUSSAIX, E .
JOURNAL OF MEDICAL VIROLOGY, 1994, 43 (03) :259-261
[2]   HIGH PREVALENCE OF HEPATITIS-C VIRUS (HCV) RNA IN DIALYSIS PATIENTS - FAILURE OF COMMERCIALLY AVAILABLE ANTIBODY TESTS TO IDENTIFY A SIGNIFICANT NUMBER OF PATIENTS WITH HCV INFECTION [J].
BUKH, J ;
WANTZIN, P ;
KROGSGAARD, K ;
KNUDSEN, F ;
PURCELL, RH ;
MILLER, RH .
JOURNAL OF INFECTIOUS DISEASES, 1993, 168 (06) :1343-1348
[3]  
CHOMCZYNSKI P, 1987, ANAL BIOCHEM, V162, P156, DOI 10.1016/0003-2697(87)90021-2
[4]   ISOLATION OF A CDNA CLONE DERIVED FROM A BLOOD-BORNE NON-A, NON-B VIRAL-HEPATITIS GENOME [J].
CHOO, QL ;
KUO, G ;
WEINER, AJ ;
OVERBY, LR ;
BRADLEY, DW ;
HOUGHTON, M .
SCIENCE, 1989, 244 (4902) :359-362
[5]   RELIABILITY OF THE 3RD-GENERATION RECOMBINANT IMMUNOBLOT ASSAY FOR HEPATITIS-C VIRUS [J].
DAMEN, M ;
ZAAIJER, HL ;
CUYPERS, HTM ;
VRIELINK, H ;
VANDERPOEL, CL ;
REESINK, HW ;
LELIE, PN .
TRANSFUSION, 1995, 35 (09) :745-749
[6]   IMPROVED DETECTION OF ANTIBODIES TO HEPATITIS-C VIRUS BY USE OF A NEW RECOMBINANT IMMUNOBLOT ASSAY [J].
JOLLERJEMELKA, HI ;
WICKI, AN ;
OPITZ, R .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1993, 12 (05) :398-400
[7]   AN ASSAY FOR CIRCULATING ANTIBODIES TO A MAJOR ETIOLOGIC VIRUS OF HUMAN NON-A, NON-B-HEPATITIS [J].
KUO, G ;
CHOO, QL ;
ALTER, HJ ;
GITNICK, GL ;
REDEKER, AG ;
PURCELL, RH ;
MIYAMURA, T ;
DIENSTAG, JL ;
ALTER, MJ ;
STEVENS, CE ;
TEGTMEIER, GE ;
BONINO, F ;
COLOMBO, M ;
LEE, WS ;
KUO, C ;
BERGER, K ;
SHUSTER, JR ;
OVERBY, LR ;
BRADLEY, DW ;
HOUGHTON, M .
SCIENCE, 1989, 244 (4902) :362-364
[8]   SEROLOGICAL STUDIES AND HEPATITIS-C VIRUS-RNA IN SERUM SAMPLES FROM BLOOD-DONORS WITH INDETERMINATE RESULTS IN 2ND-GENERATION RECOMBINANT IMMUNOBLOT ASSAY [J].
LEON, P ;
LOPEZ, JA ;
DOMINGO, CJ ;
ELOLA, C ;
ECHEVARRIA, JM .
VOX SANGUINIS, 1994, 66 (03) :245-246
[9]  
VANDERPOEL CL, 1990, LANCET, V336, P187, DOI 10.1016/0140-6736(90)91718-P
[10]   CONFIRMATION OF HEPATITIS-C VIRUS-INFECTION BY NEW 4-ANTIGEN RECOMBINANT IMMUNOBLOT ASSAY [J].
VANDERPOEL, CL ;
CUYPERS, HTM ;
REESINK, HW ;
WEINER, AJ ;
QUAN, S ;
DINELLO, R ;
VANBOVEN, JJP ;
WINKEL, I ;
MULDERFOLKERTS, D ;
EXELOEHLERS, PJ ;
SCHAASBERG, W ;
LEENTVAARKUYPERS, A ;
POLITO, A ;
HOUGHTON, M ;
LELIE, PN .
LANCET, 1991, 337 (8737) :317-319