Effects of inversion time on inversion recovery prepared ultrashort echo time (IR-UTE) imaging of bound and pore water in cortical bone

被引:32
|
作者
Li, Shihong [1 ,2 ]
Ma, Lanqing [2 ,3 ]
Chang, Eric Y. [2 ,4 ]
Shao, Hongda [2 ]
Chen, Jun [2 ]
Chung, Christine B. [2 ,4 ]
Bydder, Graeme M. [2 ]
Du, Jiang [2 ,4 ]
机构
[1] Fudan Univ, Dept Radiol, Hua Dong Hosp, Shanghai 200433, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[3] Kunming Med Univ, Hosp 1, Dept Gastroenterol, Kunming, Yunnan, Peoples R China
[4] VA San Diego Healthcare Syst, Dept Radiol, La Jolla, CA USA
关键词
UTE; IR-UTE; bound water; pore water; cortical bone; MAGNETIC-RESONANCE; MRI;
D O I
10.1002/nbm.3228
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Water is present in cortical bone in different binding states. In this study we aimed to investigate the effects of inversion time (TI) on the signal from bound and pore water in cortical bone using an adiabatic inversion recovery prepared ultrashort echo time (IR-UTE) sequence on a clinical 3T scanner. In total ten bovine midshaft samples and four human tibial midshaft samples were harvested for this study. Each cortical sample was imaged with the UTE and IR-UTE sequences with a TR of 300ms and a series of TI values ranging from 10 to 240ms. Five healthy volunteers were also imaged with the same sequence. Single- and bi-component models were utilized to calculate the T-2* and relative fractions of short and long T-2* components. Bi-component behavior of the signal from cortical bone was seen with the IR-UTE sequence, except with a TI of around 80ms, where the short T-2* component alone were seen and a mono-exponential decay pattern was observed. In vivo imaging with the IR-UTE sequence provided high contrast-to-noise images with direct visualization of bound water and reduced signal from long T-2 muscle and fat. Our preliminary results demonstrate that selective nulling of the pore water component can be achieved with the IR-UTE sequence with an appropriate TI, allowing selective imaging of the bound water component in cortical bone in vivo using clinical MR scanners. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:70 / 78
页数:9
相关论文
共 50 条
  • [1] T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging
    Guo, Tan
    Ma, Yajun
    Jerban, Saeed
    Jang, Hyungseok
    Zhao, Wei
    Chang, Eric Y.
    Chen, Min
    Bydder, Graeme M.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 634 - 645
  • [2] Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip
    Nazaran, Amin
    Carl, Michael
    Ma, Yajun
    Jerban, Saeed
    Zhu, Yanchun
    Lu, Xing
    Du, Jiang
    Chang, Eric Y.
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 60 - 64
  • [3] Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences
    Chen, Jun
    Carl, Michael
    Ma, Yajun
    Shao, Hongda
    Lu, Xing
    Chen, Bimin
    Chang, Eric Y.
    Wu, Zhihong
    Du, Jiang
    NMR IN BIOMEDICINE, 2016, 29 (10) : 1373 - 1380
  • [4] Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
    Du, Jiang
    Carl, Michael
    Bydder, Mark
    Takahashi, Atsushi
    Chung, Christine B.
    Bydder, Graeme M.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 304 - 311
  • [5] Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss
    Ma, Ya-jun
    West, Justin
    Nazaran, Amin
    Cheng, Xin
    Hoenecke, Heinz
    Du, Jiang
    Chang, Eric Y.
    SKELETAL RADIOLOGY, 2018, 47 (07) : 973 - 980
  • [6] Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss
    Ya-jun Ma
    Justin West
    Amin Nazaran
    Xin Cheng
    Heinz Hoenecke
    Jiang Du
    Eric Y. Chang
    Skeletal Radiology, 2018, 47 : 973 - 980
  • [7] Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin
    Athertya, Jiyo S.
    Shin, Soo Hyun
    Malhi, Bhavsimran Singh
    Lo, James
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2024, : 2464 - 2472
  • [8] Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin
    Athertya, Jiyo S.
    Shin, Soo Hyun
    Malhi, Bhavsimran Singh
    Lo, James
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2464 - 2472
  • [9] Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone
    Chang, Eric Y.
    Bae, Won C.
    Shao, Hongda
    Biswas, Reni
    Li, Shihong
    Chen, Jun
    Patil, Shantanu
    Healey, Robert
    D'Lima, Darryl D.
    Chung, Christine B.
    Du, Jiang
    NMR IN BIOMEDICINE, 2015, 28 (07) : 873 - 880
  • [10] Dual inversion recovery ultrashort echo time (DIR-UTE) imaging and quantification of the zone of calcified cartilage (ZCC)
    Du, J.
    Carl, M.
    Bae, W. C.
    Statum, S.
    Chang, E. Y.
    Bydder, G. M.
    Chung, C. B.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 77 - 85