Development and Characterization of a Nonelectronic Versatile Oxygenating Perfusion System for Tissue Preservation

被引:3
作者
Portillo, Daniel J. [1 ]
Gonzalez, Jose [1 ]
Villarreal, Carorina [1 ]
Salazar, Sophia J. [1 ]
Fasci, Anjelyka [1 ]
Wearden, Brandt [1 ]
Oseghale, Jessica [2 ]
Khalil, Anis [1 ]
Perillo, Thomas [1 ]
Muenchow, Leslie [3 ]
De Lorenzo, Robert [4 ]
Hood, R. Lyle [1 ,2 ,4 ]
机构
[1] Univ Texas San Antonio, Dept Mech Engn, 1 UTSA Circle, San Antonio, TX 78249 USA
[2] Univ Texas San Antonio, Dept Biomed Engn, San Antonio, TX USA
[3] Univ Texas San Antonio, Dept Biol, San Antonio, TX USA
[4] UT Hlth San Antonio, Dept Emergency Med, San Antonio, TX USA
关键词
Organ preservation; Kidney preservation; Tissue preservation; Machine perfusion; Oxygenation; HYPOTHERMIC MACHINE PERFUSION; ORGAN PRESERVATION; UNITED-STATES; COLD-STORAGE; MANAGEMENT;
D O I
10.1007/s10439-022-02977-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oxygenated machine perfusion of human organs has been shown to improve both preservation quality and time duration when compared to the current gold standard: static cold storage. However, existing machine perfusion devices designed for preservation and transportation of transplantable organs are too complicated and organ-specific to merit use as a solution for all organs. This work presents a novel, portable, and nonelectronic device potentially capable of delivering oxygenated machine perfusion to a variety of organs. An innovative pneumatic circuit system regulates a compressed oxygen source that cyclically inflates and deflates silicone tubes, which function as both the oxygenator and perfusion pump. Different combinations of silicone tubes in single or parallel configurations, with lengths ranging from 1.5 to 15.2 m, were evaluated at varying oxygen pressures from 27.6 to 110.3 kPa. The silicone tubes in parallel configurations produced higher peak perfusion pressures (70% increase), mean flow rates (102% increase), and oxygenation rates (268% increase) than the single silicone tubes that had equivalent total lengths. While pumping against a vascular resistance element that mimicked a kidney, the device achieved perfusion pressures (8.4-131.6 mmHg), flow rates (2.0-40.2 mL min(-1)), and oxygenation rates (up to 388 mu mol min(-1)) that are consistent with values used in previous kidney preservation studies. The nonelectronic device achieved those perfusion parameters using 4.4 L min(-1) of oxygen to operate. These results demonstrate that oxygenated machine perfusion can be successfully achieved without any electronic components.
引用
收藏
页码:978 / 990
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 2019, XVIVO PERFUSION SYST
[2]  
[Anonymous], OCS LIVER INFORM
[3]  
Chandan G., 2019, Gas Laws and Clinical Application
[4]  
Chung K., 2002, J Am Soc Surg Hand, V2, P78, DOI [10.1053/jssh.2002.33319, DOI 10.1053/JSSH.2002.33319]
[5]   ORGAN PRESERVATION [J].
DALESSANDRO, AM ;
SOUTHARD, JH ;
LOVE, RB ;
BELZER, FO .
SURGICAL CLINICS OF NORTH AMERICA, 1994, 74 (05) :1083-&
[6]   Systems engineering the organ preservation process for transplantation [J].
de Vries, Reinier J. ;
Yarmush, Martin ;
Uygun, Korkut .
CURRENT OPINION IN BIOTECHNOLOGY, 2019, 58 :192-201
[7]  
Dillingham TR, 2002, SOUTH MED J, V95, P875
[8]   Hypothermic Machine Perfusion of Kidney Grafts: Which Pressure is Preferred? [J].
Doorschodt, B. M. ;
Schreinemachers, M. C. J. M. ;
Behbahani, M. ;
Florquin, S. ;
Weis, J. ;
Staat, M. ;
Tolba, R. H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (03) :1051-1059
[9]   Multifunctional Thermal Management Materials with Excellent Heat Dissipation and Generation Capability for Future Electronics [J].
Feng, Chang-Ping ;
Chen, Li-Bo ;
Tian, Guo-Liang ;
Wan, Shen-Shen ;
Bai, Lu ;
Bao, Rui-Ying ;
Liu, Zheng-Ying ;
Yang, Ming-Bo ;
Yang, Wei .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (20) :18739-18745
[10]  
Gannon, 2014, MINIATURIZATION MAKE