Lumbar spine radiology: analysis of the posteroanterior projection

被引:29
作者
Brennan, PC [1 ]
Madigan, E [1 ]
机构
[1] Univ Coll Dublin, Sch Diagnost Imaging, Dublin 4, Ireland
关键词
radiation dose; image quality; tissue displacement;
D O I
10.1007/s003309900272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of the posteroanterior (PA) technique as a means of dose reduction has been used effectively in radiology departments for chest and abdominal The aim of this investigation was to establish if the PA lumbar spine projection offers any advantages over the traditional anteroposterior (AP) view in terms of radiation dose and image quality. The contribution of tissue displacement to any dose reduction was also evaluated. The first part of: Vie study involved the use of an anthropological phantom where entrance surface and an internal dose were measured for both the PA and AP projections. Entrance surface doses for both projections were then measured on randomly allocated female patients. Resultant image quality was assessed using CEC quality criteria. Anterior to posterior patient diameter was also recorded. The results demonstrated that with the PA compared with the AP projection, reductions of 38.6% (p = 0.016) and 38.9% (p = 0.02) in patient entrance surface dose and internal phantom dose, respectively. No significant differences in image quality were noted between the two projections. Patient diameter decreased by 1.8 cm with the PA view. The authors conclude that tissue displacement is the main factor for the patient dose reduction and recommend employment of the PA procedure for routine lumbar spine examinations.
引用
收藏
页码:1197 / 1201
页数:7
相关论文
共 26 条
[1]  
Al-Balool G., 1998, RADIOGRAPHY, V4, P129
[2]  
ANGHEARR FAN, 1998, RADIOGRAPHY, V4, P195
[3]  
*BIR, 1980, RAD PROT PAT MAN GOO
[4]  
Brennan P. C., 1998, RADIOGRAPHY, V4, P251
[5]   The cost-effectiveness of carbon-fibre cassettes in mobile chest radiography [J].
Brennan, PC ;
Hourihan, SP .
EUROPEAN RADIOLOGY, 1998, 8 (02) :301-305
[6]  
Brennan PC, 1995, RADIOGRAPHY TODAY, V61, P31
[7]   DOSE REDUCTION IN RADIOLOGY USING HEAVY-METAL FOILS [J].
CHAKERA, TMH ;
FLEAY, RF ;
HENSON, PW ;
COLE, SM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (659) :853-858
[8]  
*COMM EUR COMM, 1996, 16260 EUR EN
[9]   DOSE REDUCTION BY THE USE OF ERBIUM FILTRATION IN A GENERAL RADIOGRAPHIC ROOM [J].
CRANAGE, RW ;
HOWARD, CJ ;
WELSH, AD .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (771) :232-237
[10]   The use of carbon fibre material in radiographic cassettes: Estimation of the dose and contrast advantages [J].
Dance, DR ;
Lester, SA ;
Carlsson, GA ;
Sandborg, M ;
Persliden, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832) :383-390