Remote respiratory monitoring system based on developing motion magnification technique

被引:42
作者
Al-Naji, Ali [1 ]
Chahl, Javaan [2 ]
机构
[1] Univ South Australia, Sch Engn, Elect & Informat Engn, Adelaide, SA 5095, Australia
[2] Def Sci & Technol Grp, Joint & Operat Anal Div, Mawson Lakes, SA 5095, Australia
关键词
Video processing; Motion magnification; Wavelet pyramid decomposition; Motion detection; Frame subtraction;
D O I
10.1016/j.bspc.2016.05.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study is to detect and measure the rate and timing parameters of the respiratory cycle at a distance from different sleeping positions of a baby based on video imagery. This study relied on amplifying motion resulting from movement of the chest caused by inhalation and exhalation. A motion magnification technique based on a wavelet decomposition and an elliptic filter was used to magnify breathing movement that is difficult to see with the naked eye. A novel measuring method based on motion detection was used to measure respiratory rate and its time parameters by detecting the fastest moving areas in the magnified video frame sequences. The video frames were converted into a corresponding logical matrix. The experimental results on several videos for the baby at different sleeping positions show that the remote respiratory monitoring system has an accuracy of 99%. The proposed system has very low computational complexity, is feasible and safe making it suitable for the design of next generation non-contact vital signs monitoring systems. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 32 条
[1]  
Abbas AK, 2010, IFMBE PROC, V25, P1306
[2]   Neonatal non-contact respiratory monitoring based on real-time infrared thermography [J].
Abbas, Abbas K. ;
Heimann, Konrad ;
Jergus, Katrin ;
Orlikowsky, Thorsten ;
Leonhardt, Steffen .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[3]  
Al-Najjar Y., 2012, INT J SCI ENG RES, V3, P1
[4]  
[Anonymous], 2011, MEMEA 2011 2011 IEEE
[5]  
[Anonymous], 2008, P 2008 IEEE C COMP V
[6]   Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior [J].
Blanik, Nikolai ;
Abbas, Abbas K. ;
Venema, Boudewijn ;
Blazek, Vladimir ;
Leonhardt, Steffen .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (01)
[7]   Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) :568-574
[8]  
Chekmenev S., 2005, The first international conference on graphics, vision, and image processing (GVIP), Cairo, Egypt, P107
[9]  
Droitcour A, 2001, IEEE MTT S INT MICR, P175, DOI 10.1109/MWSYM.2001.966866
[10]   Non-Contact Respiratory Rate Measurement Validation for Hospitalized Patients [J].
Droitcour, Amy D. ;
Seto, Todd B. ;
Park, Byung-Kwon ;
Yamada, Shuhei ;
Vergara, Alex ;
El Hourani, Charles ;
Shing, Tommy ;
Yuen, Andrea ;
Lubecke, Victor M. ;
Boric-Lubecke, Olga .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :4812-+