Can mediastinal nodal mobility explain the low yield rates for transbronchial needle aspiration without real-time imaging?

被引:29
作者
Piet, Anna H. M.
Lagerwaard, Frank J.
Kunst, Peter W. A.
van Sornsen de Koste, John R.
Slotman, Ben J.
Senan, Suresh
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Radiat Oncol, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Pulm Dis, NL-1007 MB Amsterdam, Netherlands
关键词
lung cancer; lymph node motion; staging; transbronchial needle aspiration;
D O I
10.1378/chest.06-2964
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The diagnostic yields with transbronchial needle aspiration (TBNA) for mediastinal nodes are highly variable. Nodal positions, as assessed on a breath-hold conventional CT scan, do not account for nodal motion. We studied nodal motion on four-dimensional (4D) CT scans. Methods: A total of 47 mediastinal nodes were identified on 4D CT scans performed for radiotherapy planning in 25 patients with lung cancer. Nodes were mainly located at stations 4R, 4L, 7, and 2R, and each identified node was contoured in all 10 phases of the 4D CT scan. Nodal motion was correlated with changes in carina position. Results: The mean (+/- SD) nodal diameter was 10.2 +/- 4.0 mm; and the mean nodal volume was 1.8 +/- 2.3 mL. Movement was maximal in the craniocaudal axis (mean length, 4.7 :+/- 2.3 mm), and the corresponding mean mediolateral and ventrodorsal movements were 2.8 +/- 1.9 mm and 2.4 +/- 1.8 mm, respectively. The mean three-dimensional displacement of the nodal center was 6.2 +/- 2.9 mm, and it exceeded 10 nun in five nodes. The nodal mass was constantly present in only 25 +/- 14% of the region encompassing all nodal positions. The mean variation in craniocaudal distance between all nodes and the carina position during respiration was 5.3 +/- 2.1 mm, (range, 2.2 to 10.5 mm). Conclusions: Both nodal motion and the varying distance between the carina and nodal position may explain the lower diagnostic yields for TBNA procedures performed without real-time guidance.
引用
收藏
页码:1783 / 1787
页数:5
相关论文
共 26 条
[1]   Endoscopic ultrasound added to mediastinoscopy for preoperative staging of patients with lung cancer [J].
Annema, JT ;
Versteegh, MI ;
Veseliç, M ;
Welker, L ;
Mauad, T ;
Sont, JK ;
Willems, LNA ;
Rabe, KF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (08) :931-936
[2]  
DEKOSTE JRV, 2006, INT J RADIAT ONCOL, V64, P1221
[3]  
DEKOSTE JRV, 2002, INT J RADIAT ONCOL, V53, P115
[4]   Four-dimensional computed tomographic analysis of esophageal mobility during normal respiration [J].
Dieleman, Edith M. T. ;
Senan, Suresh ;
Vincent, Andrew ;
Lagerwaard, Frank J. ;
Slotman, Ben J. ;
de Koste, John R. van Sornsen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03) :775-780
[5]   Transesophageal ultrasound-guided fine needle aspiration improves mediastinal staging in patients with non-small cell lung cancer and normal mediastinum on computed tomography [J].
Fernandez-Esparrach, Gloria ;
Gines, Angels ;
Belda, Josep ;
Pellise, Maria ;
Solé, Manel ;
Marrades, Ramon ;
Sendino, Oriol ;
Colomo, Lluis ;
Mata, Alfredo ;
Llach, Josep ;
Bordas, Josep M. ;
Castells, Antoni .
LUNG CANCER, 2006, 54 (01) :35-40
[6]   Involved-node radiotherapy (INRT) in patients with early Hodgkin lymphoma: Concepts and guidelines [J].
Girinsky, Theodore ;
van der Maazen, Richard ;
Specht, Lena ;
Aleman, Berthe ;
Poortmans, Philip ;
Lievens, Yolande ;
Meijnders, Paul ;
Ghalibafian, Mithra ;
Meerwaldt, Jacobus ;
Noordijk, Evert .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (03) :270-277
[7]   Mediastinal lymph node sampling following positron emission tomography with fluorodeoxyglucose imaging in lung cancer staging [J].
Gupta, NC ;
Tamim, WJ ;
Graeber, GG ;
Bishop, HA ;
Hobbs, GR .
CHEST, 2001, 120 (02) :521-527
[8]   Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically normal mediastinum [J].
Herth, F. J. F. ;
Ernst, A. ;
Eberhardt, R. ;
Vilman, P. ;
Dienemann, H. ;
Krasnik, M. .
EUROPEAN RESPIRATORY JOURNAL, 2006, 28 (05) :910-914
[9]   Real-time endobronchial ultrasound guided transbronchial needle aspiration for sampling mediastinal lymph nodes [J].
Herth, F. J. F. ;
Eberhardt, R. ;
Vilmann, P. ;
Krasnik, M. ;
Ernst, A. .
THORAX, 2006, 61 (09) :795-798
[10]   Accuracy of transbronchial needle aspiration for mediastinal staging of non-small cell lung cancer: a meta-analysis [J].
Holty, JEC ;
Kuschner, WG ;
Gould, MK .
THORAX, 2005, 60 (11) :949-955