Comparative Biomechanical and Photoelastic Evaluation of Different Fixation Techniques of Sagittal Split Ramus Osteotomy in Mandibular Advancement

被引:44
作者
Loureiro Sato, Fabio Ricardo [1 ]
Asprino, Luciana [1 ]
Consani, Simonides [2 ]
de Moraes, Marcio [3 ]
机构
[1] Univ Estadual Campinas, UNICAMP, Piracicaba Dent Sch, Dept Oral & Maxillofacial Surg, BR-13414903 Sao Paulo, Brazil
[2] Univ Estadual Campinas, UNICAMP, Piracicaba Dent Sch, Dept Dent Mat, BR-13414903 Sao Paulo, Brazil
[3] Univ Estadual Campinas, UNICAMP, Piracicaba Dent Sch, Postgrad Program Oral & Maxillofacial Surg, BR-13414903 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
INTERNAL SCREW FIXATION; STABILITY; PLACEMENT; PATTERN;
D O I
10.1016/j.joms.2009.09.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present study was to comparatively evaluate the resistance and tension areas created after load incidence in different varieties of sagittal split ramus osteotomy fixation techniques. Materials and Methods: Fifty synthetic polyurethane hemimandible replicas were subjected to linear loading tests to evaluate 4 fixation techniques of the sagittal split ramus osteotomy using 2-mm system plates and screws. The hemimandibles were fixed with three 90 degrees linear screws, three 60 degrees linear screws, 3 screws in a reversed L arrangement, and one titanium miniplate. Each group was subjected to linear loading using an Instron 4411 servohydraulic mechanical testing unit. The load peak value and peak displacement were measured. Another 4 hemimandible replicas were made of photoelastic resin and subjected to photoelastic analysis after linear loading with a 3-mm displacement. Results: The results of the mechanical tests showed statistically significant differences between the fixation groups. The linear 90 degrees fixation and the reversed L arrangement presented with greater loading resistance, followed by the linear 60 degrees fixation and miniplates. In relation to the stress distribution in the photoelastic analysis, the fringes were concentrated near the osteotomy and to the lower part of the mandible in the linear 90 degrees-screw system and reversed L arrangement. In the case of the linear 60 degrees screws, most fringes were located around and between the screws. In the case of the miniplates, the fringes were concentrated around the screws near the osteotomy and more distally. Conclusion: Under the conditions tested, the linear 90 degrees and reversed L arrangements provided the most favorable behavior. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:160-166, 2010
引用
收藏
页码:160 / 166
页数:7
相关论文
共 27 条
[1]   INVITRO STRENGTH ANALYSIS OF SAGITTAL SPLIT OSTEOTOMY FIXATION - NONCOMPRESSION MONOCORTICAL PLATES VERSUS BICORTICAL POSITION SCREWS [J].
ANUCUL, B ;
WAITE, PD ;
LEMONS, JE .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (12) :1295-1299
[2]   COMPARATIVE-EVALUATION OF SCREW CONFIGURATION ON THE STABILITY OF THE SAGITTAL SPLIT OSTEOTOMY [J].
ARDARY, WC ;
TRACY, DJ ;
BROWNRIDGE, GW ;
URATA, MM .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 68 (02) :125-129
[3]   A comparative biomechanical evaluation of mandibular condyle fracture plating techniques [J].
Asprino, L ;
Consani, S ;
de Moraes, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (03) :452-456
[4]   SKELETAL STABILITY AFTER MANDIBULAR ADVANCEMENT - A COMPARISON OF 2 RIGID INTERNAL-FIXATION TECHNIQUES [J].
BLOMQVIST, JE ;
ISAKSSON, S .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (11) :1133-1137
[5]   Mechanical characteristics of the mandible after bilateral sagittal split Ramus osteotomy: Comparing 2 different fixation techniques [J].
Chuong, CJ ;
Borotikar, B ;
Schwartz-Dabney, C ;
Sinn, DP .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (01) :68-76
[6]  
EPKER BN, 1977, J ORAL SURG, V35, P157
[7]   INTERNAL SCREW FIXATION - COMPARISON OF PLACEMENT PATTERN AND RIGIDITY [J].
FOLEY, WL ;
FROST, DE ;
PAULIN, WB ;
TUCKER, MR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 47 (07) :720-723
[8]   An in vitro comparison of the effect of number and pattern of positional screws on load resistance [J].
Haug, RH ;
Barber, JE ;
Punjabi, AP .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (03) :300-308
[9]   COMPARISON OF SCREW PLACEMENT PATTERNS ON THE RIGIDITY OF THE SAGITTAL SPLIT RAMUS OSTEOTOMY - TECHNICAL NOTE [J].
KIM, HC ;
ESSAKI, S ;
KAMEYAMA, T .
JOURNAL OF CRANIO-MAXILLO-FACIAL SURGERY, 1995, 23 (01) :54-56
[10]   PHOTOELASTIC ANALYSIS OF INTERNAL SCREW FIXATION AFTER SAGITTAL SPLIT RAMUS OSTEOTOMY [J].
KIM, HC ;
ESSAKI, S ;
KAMEYAMA, T ;
YAMAMOTO, K .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1993, 21 (06) :266-270