New biocompatible polymer surface coating for stents results in a low neointimal response

被引:0
作者
Bär, FW
van der Veen, FH
Benzina, A
Habets, J
Koole, LH
机构
[1] Univ Hosp Maastricht, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
[2] Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
[3] Univ Maastricht, Ctr Biomat Res, Maastricht, Netherlands
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2000年 / 52卷 / 01期
关键词
stent; coating; hyperplasia; MMA/HEMA; polymer;
D O I
10.1002/1097-4636(200010)52:1<193::AID-JBM25>3.0.CO;2-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Clinical studies indicate a more pronounced endothelial response after stent implantation than after balloon inflation. This might be related to the metal surface of the stent, and therefore it is speculated that coating of the stent might partially prevent hyperplasia. One coated and one noncoated Palmaz-Schatz stent were implanted in two separate coronary arteries of seven pigs. The coating was composed of methylmethacrylate (MMA) (hydrophobic, 70 mol %) and 2-hydroxyethyl methacrylate (HEMA) (hydrophilic 30 mol %). After sacrifice (3 weeks), cross sections were made of the stented areas. Vessel wall reaction was calculated both independently and dependently of local vessel wall injury due to the stent struts. Overall, vessel wall reaction of the coated stents was lower than that of the non-coated stents. The degree of hyperplasia was linearly related to the degree of stent-induced vessel wall injury. Analyses of all the struts showed that significantly less hyperplasia occurred in the coated versus noncoated stents. In this porcine coronary artery model, the MMA/HEMA stent coating resulted in significantly reduced vessel wall response. However, it remains to be determined whether this favorable outcome will also be present in humans. (C) 2000 John Wiley & Sons, Inc.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 24 条
  • [1] PERCUTANEOUS IMPLANTATION OF A NEW INTRACORONARY STENT IN PIGS
    BAR, FW
    VANOPPEN, J
    DESWART, H
    VANOMMEN, V
    HAVENITH, M
    DAEMEN, M
    LEENDERS, P
    VANDERVEEN, FH
    VANLANKVELD, M
    VERDUIN, M
    BRAAK, L
    WOLFF, R
    WELLENS, HJJ
    [J]. AMERICAN HEART JOURNAL, 1991, 122 (06) : 1532 - 1541
  • [2] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [3] Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries
    Hardhammar, PA
    vanBeusekom, HMM
    Emanuelsson, HU
    Hofma, SH
    Albertsson, PA
    Verdouw, PD
    Boersma, E
    Serruys, PW
    vanderGiessen, WJ
    [J]. CIRCULATION, 1996, 93 (03) : 423 - 430
  • [4] HEMKER HC, 1986, THROMB HAEMOSTASIS, V56, P9
  • [5] AMPHIPHILIC NETWORKS .6. SWELLING AND SUSTAINED-RELEASE OF POLY(N,N-DIMETHYLACRYLAMIDE)-L-POLYISOBUTYLENE, POLY (N-N-DIMETHYLAMINO ETHYLMETHACRYLATE)-L-POLYISOBUTYLENE AND POLY(2-HYDROXYETHYL METHACRYLATE)-L-POLYISOBUTYLENE NETWORKS
    KESZLER, B
    KENNEDY, JP
    MACKEY, PW
    [J]. JOURNAL OF CONTROLLED RELEASE, 1993, 25 (1-2) : 115 - 121
  • [6] In vivo tissue compatibility of two radio-opaque polymeric biomaterials
    Kruft, MAB
    vanderVeen, FH
    Koole, LH
    [J]. BIOMATERIALS, 1997, 18 (01) : 31 - 36
  • [7] Studies on radio-opaque polymeric biomaterials with potential applications to endovascular prostheses
    Kruft, MAB
    Benzina, A
    Blezer, R
    Koole, LH
    [J]. BIOMATERIALS, 1996, 17 (18) : 1803 - 1812
  • [8] PLATELET PROCOAGULANT SURFACE AS AN ESSENTIAL PARAMETER FOR THE IN-VITRO EVALUATION OF THE BLOOD COMPATIBILITY OF POLYMERS
    LINDHOUT, T
    BLEZER, R
    MAASSEN, C
    HEIJNEN, V
    REUTELINGSPERGER, CPM
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (06) : 367 - 372
  • [9] Continued benefit of coronary stenting versus balloon angioplasty: One-year clinical follow-up of Benestent trial
    Macaya, C
    Serruys, PW
    Ruygrok, P
    Suryapranata, H
    Mast, G
    Klugmann, S
    Urban, P
    denHeijer, P
    Koch, K
    Simon, R
    Morice, MC
    Crean, P
    Bonnier, H
    Wijns, W
    Danchin, N
    Bourdonnec, C
    Morel, MA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) : 255 - 261
  • [10] IMPLANTABLE DEVICES IN THE CORONARY-ARTERY - FROM METAL TO GENES