Learning curve of vessel cannulation in rats using cumulative sum analysis

被引:4
作者
Christakis, Ioannis [1 ]
Georgiou, Panagiotis [2 ]
Minnion, James [1 ]
Constantinides, Vasilis [3 ]
Cuenco, Joyceline [1 ]
Scott, Rebecca [1 ]
Tan, Tricia [4 ]
Palazzo, Fausto [5 ]
Murphy, Kevin [1 ]
Bloom, Stephen [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Investigat Med, Div Endocrinol Diabet & Metab, London W12 0NN, England
[2] Univ London Imperial Coll Sci Technol & Med, Chelsea & Westminster Hosp NHS Fdn Trust, Dept Surg, London W12 0NN, England
[3] Imperial Coll Healthcare NHS Trust, Dept Thyroid & Endocrine Surg, London, England
[4] Univ London Imperial Coll Sci Technol & Med, Imperial Coll Healthcare NHS Trust, Dept Endocrinol, London W12 0NN, England
[5] Univ London Imperial Coll Sci Technol & Med, Imperial Coll Healthcare NHS Trust, Dept Thyroid & Endocrine Surg, London W12 0NN, England
基金
英国生物技术与生命科学研究理事会;
关键词
Rats; Animals; Operating time; Jugular vein; Femoral vein; Catheterization/instrumentation; Infusions; Parenteral/instrumentation; METABOLIC-CLEARANCE RATES; COMPETENCE; EXENDIN-4; GLUCAGON; CUSUM; MODEL;
D O I
10.1016/j.jss.2014.06.048
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Intravascular access routes are widely used for administering agents or taking blood samples in rodents. Vessel cannulation in rats is a technically challenging procedure with a risk for significant complications. The use of cumulative sum (CUSUM) analysis allows continuous monitoring of the performer's outcomes to evaluate the learning curve for a particular procedure. The aim of the present study was to assess a researcher's learning curve in the cannulation of the jugular and femoral vein in rats using CUSUM analysis. Materials and methods: A single researcher performed two hundred microsurgical operations between September 2012 and September 2013. The animals (male Wistar rats) were anesthetized with isoflurane whereas the right jugular vein and the left femoral vein were catheterized. Prospective data were collected and analyzed using CUSUM analysis. For the purposes of the study, the rat population was divided in four groups based on the order of studies; group 1 represents the first 50 animals cannulated, group 2 the next batch of 50 animals, and so forth. Results: The operating times required for cannulation of the jugular vein for groups 1, 2, 3, and 4 were 24.6 +/- 4.8, 15.9 +/- 2.5, 15.2 +/- 3.2, and 15.7 +/- 3.3 min, respectively. Group 1's operating time was significantly longer than all the other groups (P < 0.001 compared with all other groups). The operating times for groups 2, 3, and 4 did not differ significantly (P > 0.05). The cannulation of the femoral vein required a mean of 32 +/- 5.3 min for group 1, 24.9 +/- 5.7 min for group 2, 18.4 +/- 4 min for group 3, and 17.2 +/- 3.4 min for group 4. The operating time of group 1 was significantly longer when compared with all groups (P < 0.001 for all groups). Group 2 also had a longer operating time than groups 3 and 4 (P < 0.001 compared with both groups). Groups 3 and 4 did not show any statistical significant difference when their operating time was compared (P > 0.05). CUSUM analysis suggested that the number of cases required to achieve the required experience to most effectively cannulate the jugular and femoral vein is approximately 50 and 100 cases, respectively. The adverse effects of the procedure included two unexpected deaths, both of which occurred in group 1 (0.5% in total). Conclusions: The authors' experience regarding the learning curve of the cannulation of the femoral and jugular vein in rats from 200 animals operated over a period of 1 y for the evaluation of the pharmacokinetic properties of drug candidates suggests significant experience is required to optimize the operating time required for the procedure. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 27 条
[1]   Learning curve for robot-assisted Roux-en-Y gastric bypass [J].
Buchs, Nicolas C. ;
Pugin, Francois ;
Bucher, Pascal ;
Hagen, Monika E. ;
Chassot, Gilles ;
Koutny-Fong, Pascale ;
Morel, Philippe .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (04) :1116-1121
[2]   Pharmacokinetic/Pharmacodynamic Modeling of GLP-1 in Healthy Rats [J].
Cao, Yanguang ;
Gao, Wei ;
Jusko, William J. .
PHARMACEUTICAL RESEARCH, 2012, 29 (04) :1078-1086
[3]   Target-Mediated Pharmacokinetic and Pharmacodynamic Model of Exendin-4 in Rats, Monkeys, and Humans [J].
Gao, Wei ;
Jusko, William J. .
DRUG METABOLISM AND DISPOSITION, 2012, 40 (05) :990-997
[4]   Pharmacokinetic and Pharmacodynamic Modeling of Exendin-4 in Type 2 Diabetic Goto-Kakizaki Rats [J].
Gao, Wei ;
Jusko, William J. .
JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2011, 336 (03) :881-890
[5]  
George R, 2008, CAN J SURG, V51, P166
[6]   The use and effectiveness of cadaveric workshops in higher surgical training: a systematic review [J].
Gilbody, J. ;
Prasthofer, A. W. ;
Ho, K. ;
Costa, M. L. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (05) :347-352
[7]   Use of risk-adjusted CUSUM and RSPRT charts for monitoring in medical contexts [J].
Grigg, OA ;
Farewell, VT ;
Spiegelhalter, DJ .
STATISTICAL METHODS IN MEDICAL RESEARCH, 2003, 12 (02) :147-170
[8]   Cumulative sum techniques for assessing surgical results [J].
Grunkemeier, GL ;
Wu, YX ;
Furnary, AP .
ANNALS OF THORACIC SURGERY, 2003, 76 (03) :663-667
[9]   Use of the Cumulative Summation Technique to Quantitatively Assess a Surgical Learning Curve: Canine Total Hip Replacement [J].
Hayes, Graham M. ;
Ramirez, Juan ;
Hobbs, Sorrel J. Langley .
VETERINARY SURGERY, 2011, 40 (01) :1-5
[10]  
Jansen S, 2013, ANZ J SURG