Accurate assessment and prediction of noise in clinical CT images

被引:37
作者
Tian, Xiaoyu [1 ]
Samei, Ehsan [2 ,3 ]
机构
[1] Duke Univ, Dept Biomed Engn, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Carl E Ravin Adv Imaging Labs, Dept Radiol,Med Phys Grad Program,Dept Phys, Durham, NC 27705 USA
[3] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27705 USA
关键词
medical imaging; computed tomography; image quality; noise; image-based;
D O I
10.1118/1.4938588
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. Methods: The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose levels). The quantum noise in clinical images was measured by subtracting sequential slices and filtering out edges. Noise was then measured in the resultant uniform area. The noise measurement technique was validated using 17 clinical image cases and a turkey phantom. With a validated method to measure noise in clinical images, this noise was predicted by establishing the correlation between water-equivalent diameter (Dw) and noise in a variable-sized phantom and ascribing a noise level to the patient based on Dw estimated from CT image. The accuracy of this prediction model was validated using 66 clinical image sets. Results: The error in noise measurement was within 1.5 HU across two reconstruction algorithms. In terms of noise prediction, across the 83 clinical image sets, the average discrepancies between predicted and measured noise were 6.9% and 6.6% for adaptive statistical iterative reconstruction and filtered back projection reconstruction, respectively. Conclusions: This study proposed a practically applicable method to assess quantum noise in clinical images. The image-based measurement technique enables automatic quality control monitoring of image noise in clinical practice. Further, a phantom-based model can accurately predict quantum noise level in patient images. The prediction model can be used to quantitatively optimize individual protocol to achieve targeted noise level in clinical images. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 14 条
  • [1] Electronic Noise in CT Detectors: Impact on Image Noise and Artifacts
    Duan, Xinhui
    Wang, Jia
    Leng, Shuai
    Schmidt, Bernhard
    Allmendinger, Thomas
    Grant, Katharine
    Flohr, Thomas
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : W626 - W632
  • [2] Strategies for CT radiation dose optimization
    Kalra, MK
    Maher, MM
    Toth, TL
    Hamberg, LM
    Blake, MA
    Shephard, JA
    Saini, S
    [J]. RADIOLOGY, 2004, 230 (03) : 619 - 628
  • [3] System for Verifiable CT Radiation Dose Optimization Based on Image Quality. Part I. Optimization Model
    Larson, David B.
    Wang, Lily L.
    Podberesky, Daniel J.
    Goske, Marilyn J.
    [J]. RADIOLOGY, 2013, 269 (01) : 167 - 176
  • [4] Levin David C, 2008, J Am Coll Radiol, V5, P744, DOI 10.1016/j.jacr.2007.12.008
  • [5] Comparison of patient size-based methods for estimating quantum noise in CT images of the lung
    Li, Xiang
    Samei, Ehsan
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 541 - 546
  • [6] The phantom portion of the American College of Radiology (ACR) Computed Tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid
    McCollough, CH
    Bruesewitz, MR
    McNitt-Gray, MF
    Bush, K
    Ruckdeschel, T
    Payne, JT
    Brink, JA
    Zeman, RK
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2423 - 2442
  • [7] In Defense of Body CT
    McCollough, Cynthia H.
    Guimaraes, Luis
    Fletcher, Joel G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (01) : 28 - 39
  • [8] Comparison of different body size parameters for individual dose adaptation in body CT of adults
    Menke, J
    [J]. RADIOLOGY, 2005, 236 (02) : 565 - 571
  • [9] Abdominal imaging utilization in the emergency department: Trends over two decades
    Raja A.S.
    Mortele K.J.
    Hanson R.
    Sodickson A.D.
    Zane R.
    Khorasani R.
    [J]. International Journal of Emergency Medicine, 4 (1)
  • [10] Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories
    Sahbaee, Pooyan
    Segars, W. Paul
    Samei, Ehsan
    [J]. MEDICAL PHYSICS, 2014, 41 (07)