Recent Advances in Micro-Particle Image Velocimetry

被引:273
作者
Wereley, Steven T. [1 ]
Meinhart, Carl. D. [2 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Univ Calif Santa Barbara, Dept Mech Engn, Santa Barbara, CA 93106 USA
关键词
mu PIV; microfluidics; Brownian motion; microscope; optical diagnostics; MICRO-PIV; 3D FLOW; PARTICLE; VELOCITY; RESOLUTION; TRACKING; PROFILES; DEPTH;
D O I
10.1146/annurev-fluid-121108-145427
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Microfluidic devices are becoming increasingly common and are seen in applications ranging from biology to nanotechnology and manufacturing. Flow behavior in these small domains can often be counterintuitive because of the low Reynolds number or the relative importance of surface forces. Microparticle image velocimetry (mu PIV) is a quantitative method that can be used to characterize the performance of such microfluidic systems with spatial resolutions better than one micron. Illustrating the impact of this measurement technique, more than 100 journal articles are published per year that feature mu PIV velocity measurements. This article discusses the fundamentals of the technique, its theoretical background, and several applications.
引用
收藏
页码:557 / 576
页数:20
相关论文
共 56 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]   Twenty years of particle image velocimetry [J].
Adrian, RJ .
EXPERIMENTS IN FLUIDS, 2005, 39 (02) :159-169
[3]   STEREOSCOPIC PARTICLE IMAGE VELOCIMETRY [J].
ARROYO, MP ;
GREATED, CA .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) :1181-1186
[4]  
Bendat J. S., 2011, Random data: analysis and measurement procedures.
[5]   The depth of correlation in micro-PIV for high numerical aperture and immersion objectives [J].
Bourdon, Christopher J. ;
Olsen, Michael G. ;
Gorby, Allen D. .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :883-886
[6]   Validation of an analytical solution for depth of correlation in microscopic particle image velocimetry [J].
Bourdon, CJ ;
Olsen, MG ;
Gorby, AD .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (02) :318-327
[7]   Three-component micro-PIV using the continuity equation and a comparison of the performance with that of stereoscopic measurements [J].
Bown, M. R. ;
MacInnes, J. M. ;
Allen, R. W. K. .
EXPERIMENTS IN FLUIDS, 2007, 42 (02) :197-205
[8]   Biotechnology at low Reynolds numbers [J].
Brody, JP ;
Yager, P ;
Goldstein, RE ;
Austin, RH .
BIOPHYSICAL JOURNAL, 1996, 71 (06) :3430-3441
[9]   Velocity measurement in microchannels with a laser confocal microscope and particle linear image velocimetry [J].
Chao, SH ;
Holl, MR ;
Koschwanez, JH ;
Carlson, RH ;
Jang, LS ;
Meldrum, DR .
MICROFLUIDICS AND NANOFLUIDICS, 2005, 1 (02) :155-160
[10]  
Devasenathipathy S, 2003, EXP FLUIDS, V34, P504, DOI [10.1007/S00348-003-0588-Y, 10.1007/S00348-003-0588-y]