Comparisons of Vibrio fischeri, Photobacterium phosphoreum, and recombinant luminescent using Escherichia coli as BOD measurement

被引:12
作者
Cheng, Chiu-Yu [1 ]
Kuo, Jong-Tar [1 ]
Lin, Yu-Cheng [1 ]
Liao, Yi-Ru [1 ]
Chung, Ying-Chien [1 ]
机构
[1] Univ Sci & Technol China, Dept Biol Sci & Technol, Taipei, Taiwan
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2010年 / 45卷 / 02期
关键词
Biochemical oxygen demand; biosensor; Vibrio fischeri; Photobacterium phosphoreum; Escherichia coli; BIOCHEMICAL OXYGEN-DEMAND; MICROBIAL FUEL-CELL; WASTE-WATER; SENSING SYSTEM; BIOSENSOR; BIOLUMINESCENCE; TOXICITY; SENSOR; FERRICYANIDE; CULTURE;
D O I
10.1080/10934520903430020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To shorten the time needed to measure biochemical oxygen demand (BOD) in water samples and to provide a rapid feedback of the real condition of water quality, we tested and evaluated the validity and reliability of luminescent bacteria Vibrio fischeri, Photobacterium phosphoreum, and recombinant Escherichia coli as potential indicators of BOD in the domestic wastewaters. The results indicate that the luminescence intensities of these strains are dependent on temperature, pH, and BOD concentration. In comparison to the standard BOD5 method, the time needed for BOD measurement can be shortened by 90, 120, and 150 min when V. fischeri, P. phosphoreum, and recombinant E. coli, respectively, are used. Recombinant E. coli can be adapted to measure BOD in domestic wastewater containing a wide range of BOD concentrations, V. fischeri is not suitable for measuring diluted wastewater, and P. phosphoreum has only a limited application in measuring concentrated wastewater. To the best of our knowledge, this is the first report in which V. fischeri, P. phosphoreum, and recombinant luminescent E. coli are compared in terms of their potential in BOD measurement systems.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 27 条
[1]  
[Anonymous], 1992, STAND METH EX WAT WA
[2]  
[Anonymous], 1989, Molecular Cloning: A Laboratory
[3]   Development of photocatalytic biosensor for the evaluation of biochemical oxygen demand [J].
Chee, GJ ;
Nomura, Y ;
Ikebukuro, K ;
Karube, I .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :67-73
[4]   A novel approach based on ferricyanide-mediator immobilized in an ion-exchangeable biosensing film for the determination of biochemical oxygen demand [J].
Chen, Hailing ;
Ye, T'ingxiu ;
Qiu, Bin ;
Chen, Guonan ;
Chen, Xi .
ANALYTICA CHIMICA ACTA, 2008, 612 (01) :75-82
[5]   Time-dependent toxicity in the long-term inhibition assay with Vibrio fischeri [J].
Froehner, K ;
Meyer, W ;
Grimme, LH .
CHEMOSPHERE, 2002, 46 (07) :987-997
[6]  
Gil GC, 2000, BIOSENS BIOELECTRON, V15, P23, DOI 10.1016/S0956-5663(99)00074-3
[7]   Application of ring study:: Water toxicity determinations by bioluminescence assay with Vibrio fischeri [J].
Hemando, MD ;
Malato, O ;
Farré, M ;
Fernandez-Alba, AR ;
Barceló, D .
TALANTA, 2006, 69 (02) :370-376
[8]   A NOVEL BOD SENSOR BASED ON BACTERIAL LUMINESCENCE [J].
HYUN, CK ;
TAMIYA, E ;
TAKEUCHI, T ;
KARUBE, I .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (11) :1107-1111
[9]   Construction and operation of a novel mediator- and membrane-less microbial fuel cell [J].
Jang, JK ;
Pham, TH ;
Chang, IS ;
Kang, KH ;
Moon, H ;
Cho, KS ;
Kim, BH .
PROCESS BIOCHEMISTRY, 2004, 39 (08) :1007-1012
[10]   Aqueous photolysis of tetracycline and toxicity of photolytic products to luminescent bacteria [J].
Jiao, Shaojun ;
Zheng, Shourong ;
Yin, Daqiang ;
Wang, Lianhong ;
Chen, Liangyan .
CHEMOSPHERE, 2008, 73 (03) :377-382