Sizing and Operation of a Hybrid Energy Plant Composed of Industrial Gas Turbines, Renewable Energy Systems, and Energy Storage Technologies

被引:9
|
作者
Bahlawan, Hilal [1 ,2 ]
Gambarotta, Agostino [3 ,4 ]
Losi, Enzo [1 ,2 ]
Manservigi, Lucrezia [1 ,2 ]
Morini, Mirko [3 ,4 ]
Spina, Pier Ruggero [1 ,2 ]
Venturini, Mauro [1 ,2 ]
机构
[1] Univ Ferrara, Dipartimento Ingn, Via Saragat 1, I-44122 Ferrara, Italy
[2] Univ Ferrara, MechLav, Via Saragat 1, I-44122 Ferrara, Italy
[3] Univ Parma, Dipartimento Ingn & Architettura, Parco Area Sci 181-A, I-43124 Parma, Italy
[4] Univ Parma, CIDEA, Parco Area Sci 181-A, I-43124 Parma, Italy
关键词
Combined heat and power; Cooling; Energy storage; Gas turbines; Optimization; Photovoltaic power systems; Renewable energy; Storage; Stress; Thermal energy; FUEL-CELL; TECHNOECONOMIC ASSESSMENT; POWER-SYSTEMS; BIOMASS; OPTIMIZATION; HEAT; MILP;
D O I
10.1115/1.4049652
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hybrid energy plants (HEPs), which include both fossil fuel technologies and renewable energy systems, can provide an important step toward a sustainable energy supply. In fact, the hybridization of renewable energy systems with gas turbines (GTs), which are fed by fossil fuels allows an acceptable compromise, so that high fossil fuel efficiency and high share of renewables can be potentially achieved. Moreover, electrical and thermal energy storage systems increase the flexibility of the energy plant and effectively manage the variability of energy production and demand. This paper investigates the optimal sizing of a HEP, which combines an industrial GT, renewable energy systems, and energy storage technologies. The considered renewable energy system is a photovoltaic system (PV), while the energy storage technologies are electrical energy storage and thermal energy storage. Moreover, a compression chiller and a gas boiler (GB) are also considered. For this purpose, the load profiles of electricity, heating, and cooling during a whole year are taken into account for the case study of the Campus of the University of Parma (Italy). The sizing optimization problem of the different technologies composing the HEP is solved by using a genetic algorithm, with the goal of minimizing the primary energy consumption (PEC). Moreover, different operation strategies are analyzed and compared so that plant operation is also optimized. The results demonstrate that the optimal sizing of the HEP, coupled with the optimized operation strategy, allows high average cogeneration efficiency (up to 84%), thus minimizing PEC.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Renewable Energy and Energy Storage Systems
    Sayed, Enas Taha
    Olabi, Abdul Ghani
    Alami, Abdul Hai
    Radwan, Ali
    Mdallal, Ayman
    Rezk, Ahmed
    Abdelkareem, Mohammad Ali
    ENERGIES, 2023, 16 (03)
  • [22] A Survey of Hybrid Energy Storage Systems Applied for Intermittent Renewable Energy Systems
    Mamen, Attapong
    Supatti, Uthane
    2017 14TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2017, : 729 - 732
  • [23] Impact of Load and Renewable Energy Uncertainties on Single and Multiple Energy Storage Systems Sizing
    Biyya, Imane
    Aniba, Ghassane
    Maaroufi, Mohamed
    2017 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2017,
  • [24] Sizing of Battery and Supercapacitor in a Hybrid Energy Storage System for Wind Turbines
    Babazadeh, Hamed
    Gao, Wenzhong
    Lin, Jin
    Cheng, Lin
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [25] Optimal sizing of energy storage for efficient integration of renewable energy
    Harsha, Pavithra
    Dahleh, Munther
    2011 50TH IEEE CONFERENCE ON DECISION AND CONTROL AND EUROPEAN CONTROL CONFERENCE (CDC-ECC), 2011, : 5813 - 5819
  • [26] A Choice Based Sizing of Storage in Isolated Renewable Energy Systems
    Bhagwat, Ghogare Pawan
    Thakare, Mangesh S.
    2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2017, : 463 - 469
  • [27] A Brief Review on Capacity Sizing, Control and Energy Management in Hybrid Renewable Energy Systems
    Colak, Ayse
    Ahmed, Khaled
    10TH IEEE INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA 2021), 2021, : 453 - 458
  • [28] An Approach to the Optimal Operation of the Microgrid With Renewable Energy Sources and Energy Storage Systems
    Strnad, Ivan
    Skrlec, Davor
    2013 IEEE EUROCON, 2013, : 1135 - 1140
  • [29] Optimal placement and sizing of energy storage systems to improve the reliability of hybrid power distribution network with renewable energy sources
    Lata, Preet
    Vadhera, Shelly
    JOURNAL OF STATISTICS & MANAGEMENT SYSTEMS, 2020, 23 (01): : 17 - 31
  • [30] An efficient sizing method with suitable energy management strategy for hybrid renewable energy systems
    Yazdanpanah-Jahromi, Mohammad Ali
    Barakati, Seyed-Masoud
    Farahat, Said
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (10): : 1473 - 1492