DC-Biased Magnetization Based Eddy Current Thermography for Subsurface Defect Detection

被引:58
|
作者
Wu, Jianbo [1 ]
Zhu, Junzhen [2 ,3 ]
Xia, Hui [1 ]
Liu, Chengyong [1 ]
Huang, Xiaoming [1 ]
Tian, Gui Yun [2 ,4 ]
机构
[1] Sichuan Univ, Sch Mfg Sci & Engn, Chengdu 610065, Sichuan, Peoples R China
[2] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7NL, Tyne & Wear, England
[3] Army Acad Armored Forces, Dept Vehicle Engn, Beijing 100072, Peoples R China
[4] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu 610054, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetization; Permeability; Heating systems; Skin; Distortion; Eddy currents; Surface cracks; DC-biased magnetization; eddy current thermography; permeability distortion; subsurface defect detection; STRESS-CORROSION CRACKING; PULSED THERMOGRAPHY; INSPECTION; INDUCTION; CONDUCTION; CONTRAST; FIELDS;
D O I
10.1109/TII.2019.2891107
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Eddy current thermography (ECT) as one of the emerging nondestructive testing and evaluation techniques has been used for defects detection in critical components, e.g., fatigue cracks in turbine blades, bond wire lift-off in IGBT modules, lack of fusion in welded parts, etc. However, in fast inspection using the early thermal response, the thin eddy current penetration depth (skin depth) of ferromagnetic materials limits ECTs capability of detecting subsurface defects. In order to increase the detectable depth range, this paper proposes a dc-biased magnetization based ECT (DCMECT) technique. Based on the nonlinear magnetic permeability in ferromagnetic material, DCMECT can increase the thermal contrast between the defective and sound areas by the enhanced permeability distortion in the skin-depth layer. Specifically, the influences of dc-biased magnetization direction and intensity on the thermal responses (of the defective and sound areas) and their thermal contrast are investigated. Results show that the dc-biased magnetization direction has the strongest influence on the thermal response when it is parallel to the ac magnetization direction generated by the coil. Both the thermal responses of defective and sound areas decrease with the magnetization intensity increasing. Whereas, the thermal contrast between two areas increases with the magnetization intensity, which presents the enhanced defect detectability of DCMECT. The proposed technique can detect the subsurface defect with a buried depth up to 6 mm.
引用
收藏
页码:6252 / 6259
页数:8
相关论文
共 50 条
  • [1] Analysis of Eddy-Current Losses in Solid Iron Under dc-Biased Magnetization Considering Minor Hysteresis Loops
    Shima, Kazuo
    Fukami, Tadashi
    Miyata, Kenji
    Lee, Chahn
    Furukawa, Yoko
    ELECTRICAL ENGINEERING IN JAPAN, 2014, 188 (03) : 56 - 66
  • [2] Study of the DC-biased magnetization and estimation of magnetic field and iron loss of DC-biased electromagnetic systems
    Liu, S
    Liu, ZQ
    Liu, FG
    Wang, Y
    Yang, QX
    Yan, WL
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 215 - 218
  • [3] Numerical Analysis of DC-Biased Eddy Current Sensor Considering Hysteresis Effects
    Um, Dae Yong
    Kim, Min Jae
    Park, Gwan Soo
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (09)
  • [4] Depth quantification of surface-breaking cracks in ferromagnetic materials using DC-biased magnetization based induction thermography
    Wu, Jianbo
    Zhu, Junzhen
    Tian, Gui Yun
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2020, 141
  • [5] Eddy current pulsed phase thermography for subsurface defect quantitatively evaluation
    He, Yunze
    Pan, Mengchun
    Tian, GuiYun
    Chen, Dixiang
    Tang, Ying
    Zhang, Hong
    APPLIED PHYSICS LETTERS, 2013, 103 (14)
  • [6] Logarithmic analysis of eddy current thermography based on longitudinal heat conduction for subsurface defect evaluation
    Yang, Ruizhen
    He, Yunze
    INFRARED PHYSICS & TECHNOLOGY, 2014, 67 : 467 - 472
  • [7] Eddy-current loss of copper shielding under dc-biased condition in HVDC
    Zhao, Zhi-Gang
    Liu, Fu-Gui
    Cheng, Zhi-Guang
    Yan, Wei-Li
    Liu, Lan-Rong
    Zhang, Jun-Jie
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (04): : 990 - 995
  • [8] Subsurface defect detection in metals with pulsed eddy current
    Plotnikov, YA
    Bantz, WJ
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 24A AND 24B, 2005, 760 : 447 - 454
  • [9] Detection of Subsurface Defects in Steels using Pulsed Eddy Current Thermography
    Taram, A.
    Roquelet, C.
    Anderhuber, M.
    Meilland, P.
    Mouhoubi, K.
    Bodnar, J. L.
    13TH QUANTITATIVE INFRARED THERMOGRAPHY CONFERENCE, 2016, : 832 - 839
  • [10] Possibility of defect detection by eddy current thermography in marine structures
    Swiderski, Waldemar
    SCIENTIFIC JOURNALS OF THE MARITIME UNIVERSITY OF SZCZECIN-ZESZYTY NAUKOWE AKADEMII MORSKIEJ W SZCZECINIE, 2015, 44 (116): : 43 - 46