Fatal arterial rupture during angioplasty of a flow diverter in a recurrent, previously Y-stented giant MCA bifurcation aneurysm

被引:9
作者
Gentric, Jean-Christophe [1 ]
Fahed, Robert [1 ]
Darsaut, Tim E. [2 ]
Salazkin, Igor [3 ]
Roy, Daniel [1 ]
Raymond, Jean [1 ]
机构
[1] Ctr Hosp Univ Montreal, Notre Dame Hosp, Dept Radiol, Serv Neuroradiol, Montreal, PQ, Canada
[2] Univ Alberta Hosp, Mackenzie Hlth Sci Ctr, Dept Surg, Div Neurosurg, Montreal, PQ, Canada
[3] Ctr Hosp Univ Montreal Res Ctr CRCHUM, Notre Dame Hosp, Intervent Neuroradiol Res Lab, Montreal, PQ, Canada
关键词
Flow diverter; intracranial aneurysm; complication; stenting; coiling; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; DIVERSION; CT; RECANALIZATION; RECONSTRUCTION; REDUCTION;
D O I
10.1177/1591019916631147
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose A patient with a previously Y-stented giant left middle cerebral artery (MCA) bifurcation aneurysm returned with a recurrence. Materials and methods A flow diverter (FD) was deployed through one limb of the high-porosity Y-stenting construction. The proximal FD failed to expand and an attempt at balloon angioplasty led to fatal rupture of the MCA. Results Autopsy demonstrated subarachnoid hemorrhage, vessel rupture and fracture of the proximal high-porosity stent. Microscopic photographs showed that the FD had failed to open because the guiding wire had inadvertently exited and re-entered the proximal segment of the high-porosity stent partially incorporated to the wall of the MCA. Balloon dilatation of the FD which had remained collapsed between the stent and the vessel wall caused fracture of the stent and rupture of the artery. Conclusion Angioplasty and flow-diversion of previously Y-stented aneurysms can lead to serious complications.
引用
收藏
页码:278 / 286
页数:9
相关论文
共 31 条
[1]   Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis [J].
Arrese, Ignacio ;
Sarabia, Rosario ;
Pintado, Rebeca ;
Delgado-Rodriguez, Miguel .
NEUROSURGERY, 2013, 73 (02) :193-199
[2]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[3]   Endovascular treatment with flow diverters of recanalized and multitreated aneurysms initially treated by endovascular approach [J].
Benaissa, Azzedine ;
Januel, Anne-Christine ;
Herbreteau, Denis ;
Berge, Jerome ;
Aggour, Mohamed ;
Kadziolka, Krzysztof ;
Cognard, Christophe ;
Pierot, Laurent .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (01) :44-49
[4]   Flow diverter device for the treatment of small middle cerebral artery aneurysms [J].
Briganti, Francesco ;
Delehaye, Luigi ;
Leone, Giuseppe ;
Sicignano, Carmine ;
Buono, Giuseppe ;
Marseglia, Mariano ;
Caranci, Ferdinando ;
Tortora, Fabio ;
Maiuri, Francesco .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) :287-294
[5]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[6]   Periprocedural and mid-term technical and clinical events after flow diversion for intracranial aneurysms [J].
Burrows, Anthony M. ;
Cloft, Harry ;
Kallmes, David F. ;
Lanzino, Giuseppe .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (09) :646-651
[7]  
Caroff J, AJNR AM J NEURORADIO
[8]   Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device [J].
Chalouhi, Nohra ;
Chitale, Rohan ;
Starke, Robert M. ;
Jabbour, Pascal ;
Tjoumakaris, Stavropoula ;
Dumont, Aaron S. ;
Rosenwasser, Robert H. ;
Gonzalez, L. Fernando .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (01) :19-23
[9]   Stent-Assisted Coiling of Intracranial Aneurysms Predictors of Complications, Recanalization, and Outcome in 508 Cases [J].
Chalouhi, Nohra ;
Jabbour, Pascal ;
Singhal, Saurabh ;
Drueding, Ross ;
Starke, Robert M. ;
Dalyai, Richard T. ;
Tjoumakaris, Stavropoula ;
Gonzalez, L. Fernando ;
Dumont, Aaron S. ;
Rosenwasser, Robert ;
Randazzo, Ciro G. .
STROKE, 2013, 44 (05) :1348-1353
[10]   Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms [J].
Clarencon, Frederic ;
Piotin, Michel ;
Pistocchi, Silvia ;
Babic, Drazenko ;
Blanc, Raphael .
NEURORADIOLOGY, 2012, 54 (10) :1121-1125