Steady-state solutions of one-dimensional equations of non-Newtonian hemodynamics

被引:1
作者
Krivovichev, Gerasim, V [1 ]
机构
[1] St Petersburg State Univ, 7-9 Univ Skaya Nab, St Petersburg 199034, Russia
关键词
Blood flow; steady-state solutions; DENSITY-LIPOPROTEIN ACCUMULATION; CASSON FLUID-FLOW; BLOOD-FLOW; NUMERICAL-SIMULATION; RHEOLOGICAL MODELS; HYDROSTATIC RECONSTRUCTION; PULSATILE FLOW; CAROTID-ARTERY; VISCOSITY; SCHEME;
D O I
10.1142/S1793524522500334
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper is devoted to obtaining and analysis of steady-state solutions of one-dimensional equations for the simulation of blood flow when the non-Newtonian nature of blood is taken into account. The models, based on the rheological relations, widely used for the blood, are considered. The expressions for the nonlinear frictional term are presented. For the Power Law, Simplified Cross, and Quemada models, the exact integrals of the nonlinear ordinary differential equation, obtained from the averaged momentum equation, are obtained. It is demonstrated that several solutions exist for every rheological model, but the physically relevant solutions can be selected by the appropriate value of Mach number. The effects of the velocity profile and the value of hematocrit on the steady-state solutions are analyzed. It is demonstrated that the flattening of the velocity profile, which is typical for the blood, leads to the diminishing of the length of the interval, where the solution exists. The same effect is observed when the hematocrit value is increased.
引用
收藏
页数:20
相关论文
共 66 条
[41]   Analytic study of stationary hemodynamic flows in an elastic vessel with friction [J].
Mukhin, S. I. ;
Menyailova, M. A. ;
Sosnin, N. V. ;
Favorskii, A. P. .
DIFFERENTIAL EQUATIONS, 2007, 43 (07) :1011-1015
[42]   Application of non-Newtonian models to thin film flow [J].
Myers, TG .
PHYSICAL REVIEW E, 2005, 72 (06)
[43]   Pulsatile flow of a shear-thinning model for blood through a two-dimensional stenosed channel [J].
Nandakumar, N. ;
Sahu, Kirti Chandra ;
Anand, M. .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2015, 49 :29-35
[44]   Numerical modelling of Newtonian and non-Newtonian representation of blood in a distal end-to-side vascular bypass graft anastomosis [J].
O'Callaghan, S ;
Walsh, M ;
McGloughlin, T .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (01) :70-74
[45]   An Effective Fractal-Tree Closure Model for Simulating Blood Flow in Large Arterial Networks [J].
Perdikaris, Paris ;
Grinberg, Leopold ;
Karniadakis, George Em .
ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (06) :1432-1442
[46]   The unstructured lattice Boltzmann method for non-Newtonian flows [J].
Pontrelli, G. ;
Ubertini, S. ;
Succi, S. .
JOURNAL OF STATISTICAL MECHANICS-THEORY AND EXPERIMENT, 2009,
[47]   Comparison of reduced models for blood flow using Runge-Kutta discontinuous Galerkin methods [J].
Puelz, Charles ;
Canic, Suncica ;
Riviere, Beatrice ;
Rusin, Craig G. .
APPLIED NUMERICAL MATHEMATICS, 2017, 115 :114-141
[48]   The cardiovascular system: Mathematical modelling, numerical algorithms and clinical applications [J].
Quarteroni, A. ;
Manzoni, A. ;
Vergara, C. .
ACTA NUMERICA, 2017, 26 :365-590
[49]   Pulsatile non-Newtonian blood flow through a model of arterial stenosis [J].
Rabby, Mir Golam ;
Razzak, Abdur ;
Molla, Md. Mamun .
5TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2013, 56 :225-231
[50]   Numerical simulation of blood pulsatile flow in a stenosed carotid artery using different rheological models [J].
Razavi, A. ;
Shirani, E. ;
Sadeghi, M. R. .
JOURNAL OF BIOMECHANICS, 2011, 44 (11) :2021-2030