Purpose: To evaluate the perioperative complications of intraocular lens (IOL) exchange in 25 eyes of 22 patients with opacified Aqua-Sense(R) IOLs (Ophthalmic Innovations International). Setting: Department of Ophthalmology, University Hospital Aintree, Liverpool, United Kingdom. Methods: The study comprised 22 patients (25 eyes) who had previous phacoemulsification and implantation of Aqua-Sense single-piece hydrophilic acrylic IOLs in the capsular bag and developed severe late opacification of the IOL. All patients reported glare and deterioration in vision. The IOLs were explanted and replaced with new lenses. The perioperative complications were evaluated. The best corrected visual acuity (BCVA) before and after surgery was compared. Results: In 24 eyes, the opacification was complete, involving the optic, haptics, and substance of the IOLs. Uneventful IOL exchange and placement of a new IOL in the bag was achieved in 13 eyes (52%). Complications occurred in the remaining 12 eyes (48%). Ten eyes (40%) developed zonular dehiscence, 4 (16%) of which were managed with anterior chamber IOL implantation. One eye (4%) developed posterior capsule rupture and 1 eye (4%), posterior capsule rupture and zonular dehiscence. The cornea decompensated in 2 eyes (8%). One eye (4%) developed Pseudomonas keratitis. The mean BCVA (decimal scale) before and after IOL exchange was 0.57 +/- 0.24 and 0.60 +/- 0.28, respectively. There was no significant difference in visual acuity between before and after IOL exchange (P = .782, paired t test). Conclusions: Explantation of Aqua-Sense IOLs was challenging because of the tight adherence of the optic and haptics to the capsule. Long-term follow-up of patients with Aqua-Sense IOLs should be maintained.
引用
收藏
页码:2569 / 2573
页数:5
相关论文
共 12 条
  • [1] Apple DJ, 2001, ARCH OPHTHALMOL-CHIC, V119, P581
  • [2] Acrylic lens exchange for late opacification of the optic
    Dahlmann, AH
    Dhingra, N
    Chawdhary, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) : 1713 - 1714
  • [3] Late opacification of the foldable hydrophilic acrylic lens SC60B-OUV
    Frohn, A
    Dick, HB
    Augustin, AJ
    Grus, FH
    [J]. OPHTHALMOLOGY, 2001, 108 (11) : 1999 - 2004
  • [4] Postoperative opacification of 12 hydrogel foldable lenses (Hydroview®)
    Groh, MJM
    Schlötzer-Schrehardt, U
    Rummelt, C
    von Below, H
    Küchle, M
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (10) : 645 - 648
  • [5] Late surface opacification of Hydroview® intraocular lenses
    Habib, NE
    Freegard, TJ
    Gock, G
    Newman, PL
    Moate, RM
    [J]. EYE, 2002, 16 (01) : 69 - 74
  • [6] Calcification of modern foldable hydrogel intraocular lens designs
    Izak, AM
    Werner, L
    Pandey, SK
    Apple, DJ
    [J]. EYE, 2003, 17 (03) : 393 - 406
  • [7] Hydrophilic acrylic intraocular lenses
    Mamalis, N
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) : 1339 - 1340
  • [8] Post cataract-intraocular lens (IOL) surgery opacification
    Trivedi, RH
    Werner, L
    Apple, DJ
    Pandey, SK
    Izak, AM
    [J]. EYE, 2002, 16 (03) : 217 - 241
  • [9] Dense opacification of the optical component of a hydrophilic acrylic intraocular lens - A clinicopathological analysis of 9 explanted lenses
    Werner, L
    Apple, DJ
    Kaskaloglu, M
    Pandey, SK
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) : 1485 - 1492
  • [10] Complications and clinical outcomes of intraocular lens exchange in patients with calcified hydrogel lenses
    Yu, AKF
    Ng, ASY
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) : 1217 - 1222