Experimental performance evaluation of a novel designed phase change material integrated manifold heat pipe evacuated tube solar collector system

被引:83
作者
Chopra, K. [1 ,2 ]
Tyagi, V. V. [1 ]
Pathak, Atin K. [1 ]
Pandey, A. K. [3 ]
Sari, Ahmet [4 ,5 ]
机构
[1] Shri Mata Vaishno Devi Univ, Sch Energy Management, Katra 182320, Jammu & Kashmir, India
[2] Shri Mata Vaishno Devi Univ, Sch Mech Engn, Katra 182320, Jammu & Kashmir, India
[3] Sunway Univ, Sch Sci & Technol, RCNMET, 5 Jalan Univ, Petaling Jaya 47500, Selangor Darul, Malaysia
[4] Karadeniz Tech Univ, Dept Met & Mat Engn, TR-61080 Trabzon, Turkey
[5] KFUPM, Res Inst, Ctr Res Excellence Renewable Energy CORERE, Dhahran 31261, Saudi Arabia
关键词
Evacuated tube solar collector; Heat pipe; Phase change material; Solar energy; Energy analysis; Water heating system; THERMAL PERFORMANCE; WATER-HEATER; STORAGE TANK; ADVANCEMENT; CLIMATE;
D O I
10.1016/j.enconman.2019.111896
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the thermal performance of a novel solar collector integrated with stearic acid as phase change material has been investigated. In this design, the solar radiation was collected by heat pipe equipped evacuated tubes and then stored in manifold integrated with phase change material. The stored thermal energy of phase change material then transferred to water flowing through bundle of finned copper pipes placed inside the manifold. In present study, the design, the operating principle and the experimental investigation of the developed system have been presented. The developed system was investigated with different mass flow rates and also discussed the influence of varying mass flow rate on the thermal performance of system. The experimental investigation of designed and developed system has been carried out for two modes i.e. mid-day charging mode and full-day charging mode. It has been observed that for considered mass flow rates, thermal efficiency of the system was varied in the range of approximately 52-62% for full-day charging mode while for mid-day charging mode, it was varied between 55 and 72%. The maximum value of thermal efficiency was approximately 72.52% at mass flow rate of 24 LPH for mid-day charging mode. The efficiency of phase change material for both modes was varied in the range of approximately 61-64%. The annual cost and annual fuel cost of the developed system are much lower than conventional system. Also, the initial capital cost for the developed system can be recovered after 6 years of operation. However, there is no recovery of initial investment for electricity based water heating system. The proposed system overcomes two problems associated with conventional heat pipe evacuated tube solar collector: elimination of heat pipe overheating problem and low thermal conductivity of phase change materials. By this novel design of manifold, the influence of thermal stratification on the thermal performance of solar collectors can be completely eradicated.
引用
收藏
页数:13
相关论文
共 46 条
[21]   Experimental and numerical investigations on the thermal performance of a modified evacuated tube solar collector: Effect of the bypass tube [J].
Jowzi, Mohammad ;
Veysi, Farzad ;
Sadeghi, Gholamabbas .
SOLAR ENERGY, 2019, 183 :725-737
[22]   Design of Evacuated Tube Solar Collector with Heat Pipe [J].
Kumar, S. Siva ;
Kumar, K. Mohan ;
Kumar, S. R. Sanjeev .
MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) :12641-12646
[23]   Experimental and numerical investigation of a solar collector/storage system with composite phase change materials [J].
Li, Bin ;
Zhai, Xiaoqiang ;
Cheng, Xiwen .
SOLAR ENERGY, 2018, 164 :65-76
[24]   Energy performance analysis of a forced circulation solar water heating system equipped with a heat pipe evacuated tube collector under the Mediterranean climate conditions [J].
Maraj, Altin ;
Londo, Andonaq ;
Gebremedhin, Alemayehu ;
Firat, Coskun .
RENEWABLE ENERGY, 2019, 140 :874-883
[25]   Solar thermal networks operating with evacuated-tube collectors [J].
Martinez-Rodriguez, Guillermo ;
Fuentes-Silva, Amanda L. ;
Picon-Nunez, Martin .
ENERGY, 2018, 146 :26-33
[26]   Recent developments in phase change materials for energy storage applications: A review [J].
Nazir, Hassan ;
Batool, Mariah ;
Osorio, Francisco J. Bolivar ;
Isaza-Ruiz, Marllory ;
Xu, Xinhai ;
Vignarooban, K. ;
Phelan, Patrick ;
Inamuddin ;
Kannan, Arunachala M. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 129 :491-523
[27]   Novel approaches and recent developments on potential applications of phase change materials in solar energy [J].
Pandey, A. K. ;
Hossain, M. S. ;
Tyagi, V. V. ;
Abd Rahim, Nasrudin ;
Selvaraj, Jeyraj A. L. ;
Sari, Ahmet .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 :281-323
[28]   Evacuated tube solar collectors integrated with phase change materials [J].
Papadimitratos, Alexios ;
Sobhansarbandi, Sarvenaz ;
Pozdin, Vladimir ;
Zakhidov, Anvar ;
Hassanipour, Fatemeh .
SOLAR ENERGY, 2016, 129 :10-19
[29]   Performance evaluation of the senergy polycarbonate and asphalt carbon nanotube solar water heating collectors for building integration [J].
Pugsley, Adrian ;
Zacharopoulos, Aggelos ;
Smyth, Mervyn ;
Mondol, Jayanta .
RENEWABLE ENERGY, 2019, 137 :2-9
[30]   Models for forecasting monthly mean daily global solar radiation from in-situ measurements: Application in Tropical Climate, India [J].
Rao, D. V. Siva Krishna K. ;
Premalatha, M. ;
Naveen, C. .
URBAN CLIMATE, 2018, 24 :921-939