Experimental performance evaluation of a novel designed phase change material integrated manifold heat pipe evacuated tube solar collector system

被引:83
作者
Chopra, K. [1 ,2 ]
Tyagi, V. V. [1 ]
Pathak, Atin K. [1 ]
Pandey, A. K. [3 ]
Sari, Ahmet [4 ,5 ]
机构
[1] Shri Mata Vaishno Devi Univ, Sch Energy Management, Katra 182320, Jammu & Kashmir, India
[2] Shri Mata Vaishno Devi Univ, Sch Mech Engn, Katra 182320, Jammu & Kashmir, India
[3] Sunway Univ, Sch Sci & Technol, RCNMET, 5 Jalan Univ, Petaling Jaya 47500, Selangor Darul, Malaysia
[4] Karadeniz Tech Univ, Dept Met & Mat Engn, TR-61080 Trabzon, Turkey
[5] KFUPM, Res Inst, Ctr Res Excellence Renewable Energy CORERE, Dhahran 31261, Saudi Arabia
关键词
Evacuated tube solar collector; Heat pipe; Phase change material; Solar energy; Energy analysis; Water heating system; THERMAL PERFORMANCE; WATER-HEATER; STORAGE TANK; ADVANCEMENT; CLIMATE;
D O I
10.1016/j.enconman.2019.111896
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the thermal performance of a novel solar collector integrated with stearic acid as phase change material has been investigated. In this design, the solar radiation was collected by heat pipe equipped evacuated tubes and then stored in manifold integrated with phase change material. The stored thermal energy of phase change material then transferred to water flowing through bundle of finned copper pipes placed inside the manifold. In present study, the design, the operating principle and the experimental investigation of the developed system have been presented. The developed system was investigated with different mass flow rates and also discussed the influence of varying mass flow rate on the thermal performance of system. The experimental investigation of designed and developed system has been carried out for two modes i.e. mid-day charging mode and full-day charging mode. It has been observed that for considered mass flow rates, thermal efficiency of the system was varied in the range of approximately 52-62% for full-day charging mode while for mid-day charging mode, it was varied between 55 and 72%. The maximum value of thermal efficiency was approximately 72.52% at mass flow rate of 24 LPH for mid-day charging mode. The efficiency of phase change material for both modes was varied in the range of approximately 61-64%. The annual cost and annual fuel cost of the developed system are much lower than conventional system. Also, the initial capital cost for the developed system can be recovered after 6 years of operation. However, there is no recovery of initial investment for electricity based water heating system. The proposed system overcomes two problems associated with conventional heat pipe evacuated tube solar collector: elimination of heat pipe overheating problem and low thermal conductivity of phase change materials. By this novel design of manifold, the influence of thermal stratification on the thermal performance of solar collectors can be completely eradicated.
引用
收藏
页数:13
相关论文
共 46 条
[1]   On-demand operation of a compact solar water heater based on U-pipe evacuated tube solar collector combined with phase change material [J].
Abokersh, Mohamed Hany ;
El-Morsi, Mohamed ;
Sharaf, Osama ;
Abdelrahman, Wael .
SOLAR ENERGY, 2017, 155 :1130-1147
[2]  
[Anonymous], 2010, SOL WAT HEAT IND MAR
[3]  
Ashima Verma, 2019, THERM SCI ENG PROG, V11, P74
[4]   Theoretical and experimental investigation of heat pipe solar collector [J].
Azad, E. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1666-1672
[5]   An analytical and comparative study of the charging and discharging processes in a latent heat thermal storage tank for solar water heater system [J].
Bazri, Shahab ;
Badruddin, Irfan Anjum ;
Naghavi, Mohammad Sajad ;
Seng, Ong Kok ;
Wongwises, Somchai .
SOLAR ENERGY, 2019, 185 :424-438
[6]   Experimental based multilayer perceptron approach for prediction of evacuated solar collector performance in humid subtropical regions [J].
Bhowmik, Mrinal ;
Muthukumar, P. ;
Anandalakshmi, R. .
RENEWABLE ENERGY, 2019, 143 :1566-1580
[7]  
Cengel Yunus, 2017, HEAT TRANSFER PRACTI
[8]   Global advancement on experimental and thermal analysis of evacuated tube collector with and without heat pipe systems and possible applications [J].
Chopra, K. ;
Tyagi, V. V. ;
Pandey, A. K. ;
Sari, Ahmet .
APPLIED ENERGY, 2018, 228 :351-389
[9]   Improving the performance of heat pipe embedded evacuated tube collector with nanofluids and auxiliary gas system [J].
Daghigh, Roonak ;
Zandi, Pooya .
RENEWABLE ENERGY, 2019, 134 :888-901
[10]   Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector [J].
Daghigh, Roonak ;
Shafieian, Abdellah .
APPLIED THERMAL ENGINEERING, 2016, 103 :1219-1227