Novel Zn-based alloys for biodegradable stent applications: Design, development and in vitro degradation

被引:349
作者
Mostaed, E. [1 ]
Sikora-Jasinska, M. [1 ,2 ,3 ]
Mostaed, A. [4 ]
Loffredo, S. [1 ]
Demir, A. G. [1 ]
Preuitali, B. [1 ]
Mantouani, D. [2 ,3 ]
Beanland, R. [4 ]
Vedani, M. [1 ]
机构
[1] Politecn Milan, Dept Mech Engn, Via La Masa 1, I-20156 Milan, Italy
[2] Univ Laval, Dept Min Met Mat Engn, Lab Biomat & Bioengn CRC I, Quebec City, PQ, Canada
[3] Univ Laval, CHU Quebec, Res Ctr, Quebec City, PQ, Canada
[4] Univ Warwick, Dept Phys, Coventry, W Midlands, England
关键词
Zn alloys; Biodegradable stent; Extrusion; Mechanical properties; Texture; Corrosion behavior; Laser cutting; LOW-TEMPERATURE SUPERPLASTICITY; MECHANICAL-PROPERTIES; CORROSION BEHAVIOR; MAGNESIUM ALLOYS; VIVO CORROSION; MG; ZINC; MICROSTRUCTURE; BIOCOMPATIBILITY; WEAR;
D O I
10.1016/j.jmbbm.2016.03.018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The search for a degradable metal simultaneously showing mechanical properties equal or higher to that of stainless steel and uniform degradation is still an open challenge. Several magnesium-based alloys have been studied, but their degradation rate has proved to be too fast and rarely homogeneous. Fe-based alloys show appropriate mechanical properties but very low degradation rate. In the present work, four novel Zn-Mg and two Zn-Al binary alloys were investigated as potential biodegradable materials for stent applications. The alloys were developed by casting process and homogenized at 350 degrees C for 48 h followed by hot extrusion at 250 Tube extrusion was performed at 300 degrees C to produce tubes with outer/inner diameter of 4/1.5 mm as precursors for biodegradable stents. Corrosion tests were performed using Hanks' modified solution. Extruded alloys exhibited slightly superior corrosion resistance and slower degradation rate than those of their cast counterparts, but all had corrosion rates roughly half that of a standard purity Mg control. Hot extrusion of Zn-Mg alloys shifted the corrosion regime from localized pitting to more uniform erosion, mainly due to the refinement of second phase particles. Zn-0.5Mg is the most promising material for stent applications with a good combination of strength, ductility, strain hardening exponent and an appropriate rate of loss of mechanical integrity during degradation. An EBSD analysis in the vicinity of the laser cut Zn-0.5Mg tube found no grain coarsening or texture modification confirming that, after laser cutting, the grain size and texture orientation of the final stent remains unchanged. This work shows the potential for Zn alloys to be considered for stent applications. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:581 / 602
页数:22
相关论文
共 73 条
[1]   Factors affecting the anodic behaviour of zinc electrode in borate solutions [J].
Abd El Aal, EE .
CORROSION SCIENCE, 2006, 48 (02) :343-360
[2]   Surface modification of magnesium by NaHCO3 and corrosion behavior in Hank's solution for new biomaterial applications [J].
Al-Abdullat, Y ;
Tsutsumi, S ;
Nakajima, N ;
Ohta, M ;
Kuwahara, H ;
Ikeuchi, K .
MATERIALS TRANSACTIONS, 2001, 42 (08) :1777-1780
[3]  
[Anonymous], J BIOMED MAT RES B
[4]  
[Anonymous], 2004, ASTM E8 04
[5]  
[Anonymous], PURE ZINC NORMAL ELE
[6]  
[Anonymous], 1998, Annual Book of ASTM Standards
[7]  
ASTM, ASTM G31-72
[8]   The influence of heat treatment on the sliding wear behavior of a ZA-27 alloy [J].
Babic, Miroslav ;
Mitrovic, Slobodan ;
Jeremic, Branislav .
TRIBOLOGY INTERNATIONAL, 2010, 43 (1-2) :16-21
[9]   Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents [J].
Bowen, Patrick K. ;
Guillory, Roger J., II ;
Shearier, Emily R. ;
Seitz, Jan-Marten ;
Drelich, Jaroslaw ;
Bocks, Martin ;
Zhao, Feng ;
Goldman, Jeremy .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 :467-472
[10]   Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents [J].
Bowen, Patrick K. ;
Drelich, Jaroslaw ;
Goldman, Jeremy .
ADVANCED MATERIALS, 2013, 25 (18) :2577-2582