Meta-analysis of the diagnostic performance of stress perfusion cardiovascular magnetic resonance for detection of coronary artery disease

被引:180
作者
Hamon, Michele [1 ,2 ]
Fau, Georges [1 ]
Nee, Guillaume [3 ]
Ehtisham, Javed [4 ]
Morello, Remy [5 ]
Hamon, Martial [4 ,6 ]
机构
[1] Univ Hosp Caen, Dept Radiol, Caen, France
[2] INSERM 919, Caen, France
[3] CNRS, UMR 6072, Greyc Lab, Caen, France
[4] Univ Hosp Caen, Dept Cardiol, Caen, France
[5] Univ Hosp Caen, Dept Stat, Caen, France
[6] Inst Pasteur, INSERM 744, Lille, France
关键词
EMISSION COMPUTED-TOMOGRAPHY; MYOCARDIAL-PERFUSION; FLOW RESERVE; 1ST-PASS PERFUSION; SYSTEMATIC REVIEWS; PROGNOSTIC VALUE; T; MR; ENHANCEMENT; MULTICENTER;
D O I
10.1186/1532-429X-12-29
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Evaluation of the diagnostic accuracy of stress perfusion cardiovascular magnetic resonance for the diagnosis of significant obstructive coronary artery disease (CAD) through meta-analysis of the available data. Methodology: Original articles in any language published before July 2009 were selected from available databases (MEDLINE, Cochrane Library and BioMedCentral) using the combined search terms of magnetic resonance, perfusion, and coronary angiography; with the exploded term coronary artery disease. Statistical analysis was only performed on studies that: (1) used a [greater than or equal to] 1.5 Tesla MR scanner; (2) employed invasive coronary angiography as the reference standard for diagnosing significant obstructive CAD, defined as a [greater than or equal to] 50% diameter stenosis; and (3) provided sufficient data to permit analysis. Results: From the 263 citations identified, 55 relevant original articles were selected. Only 35 fulfilled all of the inclusion criteria, and of these 26 presented data on patient-based analysis. The overall patient-based analysis demonstrated a sensitivity of 89% (95% CI: 88-91%), and a specificity of 80% (95% CI: 78-83%). Adenosine stress perfusion CMR had better sensitivity than with dipyridamole (90% (88-92%) versus 86% (80-90%), P = 0.022), and a tendency to a better specificity (81% (78-84%) versus 77% (71-82%), P = 0.065). Conclusion: Stress perfusion CMR is highly sensitive for detection of CAD but its specificity remains moderate.
引用
收藏
页数:10
相关论文
共 50 条
[1]   Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance [J].
Al-Saadi, N ;
Nagel, E ;
Gross, M ;
Bornstedt, A ;
Schnackenburg, B ;
Klein, C ;
Klimek, W ;
Oswald, H ;
Fleck, E .
CIRCULATION, 2000, 101 (12) :1379-1383
[2]   Safety of adenosine stress magnetic resonance imaging using a mobile cardiac magnetic resonance system [J].
Bernhardt, Peter ;
Steffens, Michael ;
Kleinertz, Klaus ;
Morell, Roland ;
Budde, Rainer ;
Leischik, Roman ;
Kraemer, Alfred ;
Overhoff, Ulrich ;
Strohm, Oliver .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (03) :475-478
[3]   Combined coronary and perfusion cardiovascular magnetic resonance for the assessment of coronary artery stenosis [J].
Bunce, NH ;
Reyes, E ;
Keegan, J ;
Bunce, C ;
Davies, SW ;
Lorenz, CH ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (02) :527-539
[4]  
CHENG AS, 2007, J AM COLL CARDIOL, V2440, P2249
[5]   Combined first-pass perfusion and viability study at MR imaging in patients with non-ST segment-elevation acute coronary syndromes: Feasibility study [J].
Chiu, CW ;
So, NMC ;
Lam, WWM ;
Chan, KY ;
Sanderson, JE .
RADIOLOGY, 2003, 226 (03) :717-722
[6]   Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve [J].
Costa, Marco A. ;
Shoemaker, Steven ;
Futamatsu, Hideki ;
Klassen, Chris ;
Anglolillo, Dominick J. ;
Nguyen, Minh ;
Siuciak, Alan ;
Gilmore, Paul ;
Zenni, Martin M. ;
Guzman, Luis ;
Bass, Theodore A. ;
Wilke, Norbert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (06) :514-522
[7]   Diagnostic performance of stress perfusion and delayed-enhancement MR imaging in patients with coronary artery disease [J].
Cury, RC ;
Cattani, CAM ;
Gabure, LAG ;
Racy, DJ ;
de Gois, JM ;
Siebert, U ;
Lima, SS ;
Brady, TJ .
RADIOLOGY, 2006, 240 (01) :39-45
[8]   Conducting systematic reviews of diagnostic studies: Didactic guidelines [J].
Devillé W.L. ;
Buntinx F. ;
Bouter L.M. ;
Montori V.M. ;
De Vet H.C.W. ;
Van Der Windt D.A.W.M. ;
Bezemer P.D. .
BMC Medical Research Methodology, 2 (1) :1-13
[9]   On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies [J].
Di Bella, EVR ;
Parker, DL ;
Sinusas, AJ .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1295-1299
[10]   The impact of myocardial flow reserve on the detection of coronary artery disease by perfusion Imaging methods: An NHLBI WISE Study [J].
Doyle, M ;
Fuisz, A ;
Kortright, E ;
Biederman, RWW ;
Walsh, EG ;
Martin, ET ;
Tauxe, L ;
Rogers, WJ ;
Merz, CNB ;
Pepine, C ;
Sharaf, B ;
Pohost, GM .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (03) :475-485