Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair

被引:115
|
作者
McNally, Michael M. [1 ]
Scali, Salvatore T. [1 ]
Feezor, Robert J. [1 ]
Neal, Daniel [1 ]
Huber, Thomas S. [1 ]
Beck, Adam W. [1 ]
机构
[1] Univ Florida, Coll Med, Dept Surg, Div Vasc Surg & Endovasc Therapy, Gainesville, FL 32610 USA
关键词
IONIZING-RADIATION; ANEURYSM; RISK; SAFETY; EVAR;
D O I
10.1016/j.jvs.2014.07.097
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Endovascular surgery has revolutionized the treatment of aortic aneurysms; however, these improvements have come at the cost of increased radiation and contrast exposure, particularly for more complex procedures. Three-dimensional (3D) fusion computed tomography (CT) imaging is a new technology that may facilitate these repairs. The purpose of this analysis was to determine the effect of using intraoperative 3D fusion CT on the performance of fenestrated endovascular aortic repair (FEVAR). Methods: Our institutional database was reviewed to identify patients undergoing branched or FEVAR. Patients treated using 3D fusion CT were compared with patients treated in the immediate 12-month period before implementation of this technology when procedures were performed in a standard hybrid operating room without CT fusion capabilities. Primary end points included patient radiation exposure (cumulated air kerma: mGy), fluoroscopy time (minutes), contrast usage (mL), and procedure time (minutes). Patients were grouped by the number of aortic graft fenestrations revascularized with a stent graft, and operative outcomes were compared. Results: A total of 72 patients (41 before vs 31 after 3D fusion CT implementation) underwent FEVAR from September 2012 through March 2014. For two-vessel fenestrated endografts, there was a significant decrease in radiation exposure (3400 +/- 1900 vs 1380 +/- 520 mGy; P = .001), fluoroscopy time (63 +/- 29 vs 41 +/- 11 minutes; P = .02), and contrast usage (69 +/- 16 vs 26 +/- 8 mL; P = .0002) with intraoperative 3D fusion CT. Similarly, for combined three-vessel and four-vessel FEVAR, significantly decreased radiation exposure (5400 +/- 2225 vs 2700 +/- 1400 mGy; P < .0001), fluoroscopy time (89 +/- 36 vs 64 +/- 21 minutes; P = .02), contrast usage (90 +/- 25 vs 39 +/- 17 mL; P < .0001), and procedure time (330 +/- 100 vs 230 +/- 50 minutes; P = .002) was noted. Estimated blood loss was significantly less (P < .0001), and length of stay had a trend (P = .07) toward being lower for all patients in the 3D fusion CT group. Conclusions: These results demonstrate that use of intraoperative 3D fusion CT imaging during FEVAR can significantly decrease radiation exposure, procedure time, and contrast usage, which may also decrease the overall physiologic impact of the repair.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 50 条
  • [1] Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair (vol 61, pg 309, 2015)
    McNally, M. M.
    Scali, S. T.
    Feezor, R. J.
    Neal, D.
    Huber, T. S.
    Beck, A. W.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (05) : 1382 - 1382
  • [2] Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair (vol 61, pg 39, 2015)
    McNally, M. M.
    Scali, S. T.
    Feezor, R. J.
    Neal, D.
    Huber, T. S.
    Beck, A. W.
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 839 - 839
  • [3] Image-Based Three-Dimensional Fusion Computed Tomography Decreases Radiation Exposure, Fluoroscopy Time, and Procedure Time During Endovascular Aortic Aneurysm Repair
    Southerland, Kevin W.
    Nag, Uttara
    Turner, Megan
    Gilmore, Brian
    McCann, Richard
    Long, Chandler
    Cox, Mitchell
    Shortell, Cynthia
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E61 - E61
  • [4] Impact of onlay fusion and cone beam computed tomography on radiation exposure and technical assessment of fenestrated-branched endovascular aortic repair
    Tenorio, Emanuel R.
    Oderich, Gustavo S.
    Sandri, Giuliano A.
    Ozbek, Pinar
    Karkkainen, Jussi M.
    Macedo, Thanila A.
    Vrtiska, Terri
    Cha, Stephen
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (04) : 1045 - +
  • [5] Is three-dimensional computed tomography reconstruction justified before endovascular aortic aneurysm repair?
    Sprouse, LR
    Meier, GH
    Parent, FN
    DeMasi, RJ
    Stokes, GK
    LeSar, CJ
    Marcinczyk, MJ
    Mendoza, B
    JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) : 443 - 447
  • [6] Intraoperative computed tomography during fenestrated and branched endovascular aortic repair: a feasibility study
    Schroder-Aasen, Anne Marte
    Carling, Ulrik
    Aalokken, Trond Mogens
    Rasmussen, Margrethe Kallestad
    Dorenberg, Eric
    ACTA RADIOLOGICA, 2023, 64 (06) : 2205 - 2210
  • [7] The Use of Advanced Three-Dimensional Computed Tomography During Simple and Complex Endovascular Aortic Aneurysm Repairs
    Malkoc, Aldin
    Gnanadev, Raja
    Shoemaker, Hailey B.
    Alach, Ahmad
    Vo, Trung D.
    Behseresht, Jason
    Tayyarah, Majid
    Andacheh, Iden
    Hsu, Jeffrey H.
    ANNALS OF VASCULAR SURGERY, 2024, 106 : 90 - 98
  • [8] Feasibility of three-dimensional fusion imaging with multimodality roadmap system during endovascular aortic repair
    Hiraoka, Arudo
    Shiraya, Suguru
    Chikazawa, Genta
    Ishida, Atsuhisa
    Miyake, Koichi
    Sakaguchi, Taichi
    Yoshitaka, Hidenori
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (04) : 1175 - 1182
  • [9] Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair
    Hertault, A.
    Maurel, B.
    Sobocinski, J.
    Gonzalez, T. Martin
    Le Roux, M.
    Azzaoui, R.
    Midulla, M.
    Haulon, S.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (04) : 382 - 390
  • [10] Three-Dimensional to Three-Dimensional Image Fusion-Guided Thoracic Endovascular Aortic Repair without Iodine injection
    Barral, Pierre-Antoine
    De Masi-Jacquier, Mariangela
    Gaudry, Marine
    Boutboul, Dustin
    Bartoli, Jean-Michel
    Jacquier, Alexis
    Piquet, Philippe
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (08) : 1201 - 1203