Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair

被引:115
作者
McNally, Michael M. [1 ]
Scali, Salvatore T. [1 ]
Feezor, Robert J. [1 ]
Neal, Daniel [1 ]
Huber, Thomas S. [1 ]
Beck, Adam W. [1 ]
机构
[1] Univ Florida, Coll Med, Dept Surg, Div Vasc Surg & Endovasc Therapy, Gainesville, FL 32610 USA
关键词
IONIZING-RADIATION; ANEURYSM; RISK; SAFETY; EVAR;
D O I
10.1016/j.jvs.2014.07.097
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Endovascular surgery has revolutionized the treatment of aortic aneurysms; however, these improvements have come at the cost of increased radiation and contrast exposure, particularly for more complex procedures. Three-dimensional (3D) fusion computed tomography (CT) imaging is a new technology that may facilitate these repairs. The purpose of this analysis was to determine the effect of using intraoperative 3D fusion CT on the performance of fenestrated endovascular aortic repair (FEVAR). Methods: Our institutional database was reviewed to identify patients undergoing branched or FEVAR. Patients treated using 3D fusion CT were compared with patients treated in the immediate 12-month period before implementation of this technology when procedures were performed in a standard hybrid operating room without CT fusion capabilities. Primary end points included patient radiation exposure (cumulated air kerma: mGy), fluoroscopy time (minutes), contrast usage (mL), and procedure time (minutes). Patients were grouped by the number of aortic graft fenestrations revascularized with a stent graft, and operative outcomes were compared. Results: A total of 72 patients (41 before vs 31 after 3D fusion CT implementation) underwent FEVAR from September 2012 through March 2014. For two-vessel fenestrated endografts, there was a significant decrease in radiation exposure (3400 +/- 1900 vs 1380 +/- 520 mGy; P = .001), fluoroscopy time (63 +/- 29 vs 41 +/- 11 minutes; P = .02), and contrast usage (69 +/- 16 vs 26 +/- 8 mL; P = .0002) with intraoperative 3D fusion CT. Similarly, for combined three-vessel and four-vessel FEVAR, significantly decreased radiation exposure (5400 +/- 2225 vs 2700 +/- 1400 mGy; P < .0001), fluoroscopy time (89 +/- 36 vs 64 +/- 21 minutes; P = .02), contrast usage (90 +/- 25 vs 39 +/- 17 mL; P < .0001), and procedure time (330 +/- 100 vs 230 +/- 50 minutes; P = .002) was noted. Estimated blood loss was significantly less (P < .0001), and length of stay had a trend (P = .07) toward being lower for all patients in the 3D fusion CT group. Conclusions: These results demonstrate that use of intraoperative 3D fusion CT imaging during FEVAR can significantly decrease radiation exposure, procedure time, and contrast usage, which may also decrease the overall physiologic impact of the repair.
引用
收藏
页码:309 / 316
页数:8
相关论文
共 28 条
[1]   Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Fillinger, MF ;
Matsumura, JS ;
Rutherford, RB ;
White, GH ;
Blankensteijn, JD ;
Bernhard, VM ;
Harris, PL ;
Kent, KC ;
May, J ;
Veith, FJ ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1061-1066
[2]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[3]   Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures [J].
Chen, Jersey ;
Einstein, Andrew J. ;
Fazel, Reza ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Ross, Joseph S. ;
Ting, Henry H. ;
Shah, Nilay D. ;
Nasir, Khurram ;
Nallamothu, Brahmajee K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (09) :702-711
[4]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[5]   Fate of patients with spinal cord ischemia complicating thoracic endovascular aortic repair [J].
DeSart, Kenneth ;
Scali, Salvatore T. ;
Feezor, Robert J. ;
Hong, Michael ;
Hess, Philip J., Jr. ;
Beaver, Thomas M. ;
Huber, Thomas S. ;
Beck, Adam W. .
JOURNAL OF VASCULAR SURGERY, 2013, 58 (03) :635-+
[6]   Optimizing Radiation Use During Fluoroscopic Procedures: A Quality and Safety Improvement Project [J].
Duncan, James R. ;
Street, Mandie ;
Strother, Marshall ;
Picus, Daniel .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (11) :847-853
[7]   A summary of recommendations for occupational radiation protection in interventional cardiology [J].
Duran, Ariel ;
Hian, Sim Kui ;
Miller, Donald L. ;
Le Heron, John ;
Padovani, Renato ;
Vano, Eliseo .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) :562-567
[8]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[9]   Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures. [J].
Fazel, Reza ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Ross, Joseph S. ;
Chen, Jersey ;
Ting, Henry H. ;
Shah, Nilay D. ;
Nasir, Khurram ;
Einstein, Andrew J. ;
Nallamothu, Brahmajee K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (09) :849-857
[10]   Branched endografts for thoracoabdominal aneurysms [J].
Greenberg, Roy ;
Eagleton, Matthew ;
Mastracci, Tara .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (06) :S171-S178