Prospective Comparison of Synthesized Mammography with DBT and Full-Field Digital Mammography with DBT Uncovers Recall Disagreements That may Impact Cancer Detection

被引:5
作者
Huang, Monica L. [1 ]
Hess, Kenneth [2 ]
Ma, Junsheng [3 ]
Santiago, Lumarie [1 ]
Scoggins, Marion E. [1 ]
Arribas, Elsa [1 ]
Adrada, Beatriz E. [1 ]
Le-Petross, Huong T. [1 ]
Leung, Jessica W. T. [1 ]
Yang, Wei [1 ]
Geiser, William [4 ]
Candelaria, Rosalind P. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Breast Imaging, Unit 1350, Holcombe 1515, 1515, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Texas KH, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Texas JM, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Texas WG, Houston, TX USA
关键词
Synthesized mammography; Digital breast tomosynthesis; Calcifications; RECONSTRUCTED PROJECTION IMAGES; BREAST TOMOSYNTHESIS; 2-DIMENSIONAL MAMMOGRAPHY; SAMPLE-SIZE; IMPLEMENTATION; PERFORMANCE; MICROCALCIFICATIONS; CALCIFICATIONS;
D O I
10.1016/j.acra.2021.08.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Synthesized mammography with digital breast tomosynthesis (SM+DBT) and full-field digital mammography with DBT were prospectively evaluated for recall rate (RR), cancer detection rate (CDR), positive predictive value 1 (PPV1), lesion recall differences, and disagreements in recall for additional imaging. Materials and Methods: From December 15, 2015 to January 15, 2017, after informed consent was obtained for this Health Insurance Portability and Accountability Act compliant study, each enrolled patient's SM+DBT and FFDM+DBT were interpreted sequentially by one of eight radiologists. RR, CDR, PPV1, and imaging findings (asymmetry, focal asymmetry, mass, architectural distortion, and calcifications) recalled were reviewed.Results: For SM+DBT and FFDM+DBT in 1022 patients, RR was 7.3% and 7.9% (SM+DBT vs. FFDM+DBT: diff=-0.6%; 90% CI=-1.4%, 0.1%); CDR was 6.8 and 7.8 per 1000 (SM+DBT vs. FFDM+DBT: diff=-1.0, 95% CI=-5.5, 2.8, p = 0.317); PPV1 was 9.3% and 9.9% (relative positive predictive value for SM+DBT vs. FFDM+DBT: 0.95, 95% CI: 0.73-1.22, p = 0.669). FFDM+DBT detected eight cancers; SM+DBT detected seven (missed 1 cancer with calcifications). SM+DBT and FFDM+DBT disagreed on patient recall for additional imaging in 19 patients, with majority (68%, 13/19 patients) in the recall of patients for calcifications. For calcifications, SM+DBT recalled six patients that FFDM+DBT did not recall, and FFDM+DBT recalled seven patients that SM+DBT did not recall, even though the total number of calcifications finding recalled was similar overall for both SM+DBT and FFDM+DBT.Conclusion: Disagreement in recall of patients for calcifications may impact cancer detection by SM+DBT, warranting further investigation.
引用
收藏
页码:1039 / 1045
页数:7
相关论文
共 38 条
  • [1] A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial
    Aase, Hildegunn S.
    Holen, Asne S.
    Pedersen, Kristin
    Houssami, Nehmat
    Haldorsen, Ingfrid S.
    Sebuodegard, Sofie
    Hanestad, Berit
    Hofvind, Solveig
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (03) : 1175 - 1186
  • [2] Diagnostic Efficacy of Synthesized 2D Digital Breast Tomosynthesis in Multi-ethnic Malaysian Population
    Ab Mumin, N.
    Rahmat, K.
    Fadzli, F.
    Ramli, M. T.
    Westerhout, C. J.
    Ramli, N.
    Rozalli, F. I.
    Ng, K. H.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] Synthesized Mammography: The New Standard of Care When Screening for Breast Cancer with Digital Breast Tomosynthesis?
    Ambinder, Emily B.
    Harvey, Susan C.
    Panigrahi, Babita
    Li, Ximin
    Woods, Ryan W.
    [J]. ACADEMIC RADIOLOGY, 2018, 25 (08) : 973 - 976
  • [4] Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population
    Aujero, Mireille P.
    Gavenonis, Sara C.
    Benjamin, Ron
    Zhang, Zugui
    Holt, Jacqueline S.
    [J]. RADIOLOGY, 2017, 283 (01) : 70 - 76
  • [5] Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison
    Barca, Patrizio
    Lamastra, Rocco
    Aringhieri, Giacomo
    Tucciariello, Raffaele Maria
    Traino, Antonio
    Fantacci, Maria Evelina
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1141 - 1152
  • [6] Effect of implementing digital breast tomosynthesis (DBT) instead of mammography on population screening outcomes including interval cancer rates: Results of the Trento DBT pilot evaluation
    Bernardi, Daniela
    Gentilini, Maria A.
    De Nisi, Martina
    Pellegrini, Marco
    Fanto, Carmine
    Valentini, Marvi
    Sabatino, Vincenzo
    Luparia, Andrea
    Houssami, Nehmat
    [J]. BREAST, 2020, 50 : 135 - 140
  • [7] Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program
    Caumo, Francesca
    Zorzi, Manuel
    Brunelli, Silvia
    Romanucci, Giovanna
    Rella, Rossella
    Cugola, Loredana
    Bricolo, Paola
    Fedato, Chiara
    Montemezzi, Stefania
    Houssami, Nehmat
    [J]. RADIOLOGY, 2018, 287 (01) : 37 - 46
  • [8] Comparison of two-dimensional synthesized mammogram (2DSM) and conventional full-field digital mammogram (FFDM) for evaluation of breast cancer
    Choi, Gayoung
    Woo, Ok Hee
    Shin, Hye Seon
    Jang, Seonah
    Cho, Kyu Ran
    Seo, Bo Kyoung
    [J]. CLINICAL IMAGING, 2017, 43 : 170 - 174
  • [9] Clinical implementation of synthesized mammography with digital breast tomosynthesis in a routine clinical practice
    Freer, Phoebe E.
    Riegert, Joanna
    Eisenmenger, Laura
    Ose, Dominik
    Winkler, Nicole
    Stein, Matthew A.
    Stoddard, Gregory J.
    Hess, Rachel
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2017, 166 (02) : 501 - 509
  • [10] Artifacts in Digital Breast Tomosynthesis
    Geiser, William R.
    Einstein, Samuel A.
    Yang, Wei-Tse
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 926 - 932