Fatigue behavior of the resin-resin bond of partially replaced resin-based composite restorations

被引:0
|
作者
Frankenberger, R
Krämer, N
Ebert, J
Lohbauer, U
Käppel, S
Ten Weges, S
Petschelt, A
机构
[1] Univ Erlangen Nurnberg, Mat Sci Lab, Erlangen, Germany
[2] Univ Erlangen Nurnberg, Policlin Operat Dent & Periodontol, Erlangen, Germany
来源
AMERICAN JOURNAL OF DENTISTRY | 2003年 / 16卷 / 01期
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purposes (1) To evaluate different pre-treatment modes for partial resin-based composite repair using a shear bond strength fatigue design on aged specimens, and (2) to investigate the effect of these pre-treatments on aged and partially replaced Class II resin-based composite restorations. Materials and Methods: (Study 1) 150 composite discs (Tetric Ceram) were light-cured, secondary cured, and stored in water for 365 days. The specimens were randomly assigned to five pretreatment groups (n=30): (1) Roughening with a finishing diamond bur + dentin bonding system (DBS, Syntac Classic), (2) Roughening with a silicon carbide bur + DBS, (3) Roughening with a silicon carbide bur + DBS + Tetric Flow, (4) silica-coating (CoJet) + DBS, and (5) silica-coating + dentin bonding agent + Tetric Flow. The disks were restored with fresh repair composite cylinders and after 24-hour water storage, initial bond strengths (n=10) and fatigue bond strengths (n=20; 5,000 cycles in shear mode) were evaluated and fracture modes determined under a SEM. (Study 2): 40 Class II restorations (EBS Multi/Pertac II) were placed in extracted human third molars. The specimens were stored for 365 days and then replaced partially by removing the proximal box and leaving the occlusal part. The partial repairs (Pertac 11) were placed after identical pre-treatment modes A-E (n=8). After thermomechanical loading (100,000 x 50 N, simultaneously x2,500 at 5degreesC/55degreesC), marginal quality between old and fresh composite was evaluated by SEM at x200 magnification and dye penetration was observed by light microscopy under x50 magnification. Results: Initial repair bond strengths were significantly higher for the groups with additional application of flowable composite compared to composite only (P< 0.05; Mann Whitney U test). Diamond finishing revealed the lowest bond strengths. Fatigue bond strengths exhibited the worst results for Group 1 as well, but were similar for Groups 2-5. In the Class II partial repair simulation, Groups 3 and 5 with additional flowable lining exhibited significantly better marginal quality and significantly lower leakage, whereas the other groups revealed up to 100% separation between aged and freshly applied composite. (Am J Dent 2003; 16:17-22).
引用
收藏
页码:17 / 22
页数:6
相关论文
共 50 条
  • [41] Cavity preparation devices: Effect on microleakage of Class V resin-based composite restorations
    Setien, VJ
    Cobb, DS
    Denehy, GE
    Vargas, MA
    AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (03): : 157 - 162
  • [42] Dental cavity liners for Class I and Class II resin-based composite restorations
    Schenkel, Andrew B.
    Peltz, Ivy
    Veitz-Keenan, Analia
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (10):
  • [43] COMMENTARY. effect of finishing instrumentation on the marginal integrity of resin-based composite restorations
    Leinfelder, Karl
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2010, 22 (02) : 113 - 113
  • [44] Resin-based composite materials: elution and pollution
    Steven Mulligan
    Paul V. Hatton
    Nicolas Martin
    British Dental Journal, 2022, 232 : 644 - 652
  • [45] Simulated oral environment and microleakage of Class II resin-based composite and sandwich restorations
    Besnault, C
    Attal, JP
    AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (03): : 186 - 190
  • [46] Effect of plasma arc curing on the microleakage of Class V resin-based composite restorations
    Brackett, WW
    Haisch, LD
    Covey, DA
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (03): : 121 - 122
  • [47] Effect of LED curing on microleakage and microhardness of Class V resin-based composite restorations
    Oberholzer, TG
    Schünemann, M
    Kidd, M
    INTERNATIONAL DENTAL JOURNAL, 2004, 54 (01) : 15 - 20
  • [48] Energy dependent polymerization of resin-based composite
    Halvorson, RH
    Erickson, RL
    Davidson, CL
    DENTAL MATERIALS, 2002, 18 (06) : 463 - 469
  • [49] The Use of Resin-based Composite in Children: An Update
    Donly, Kevin J.
    Garcia-Godoy, Franklin
    PEDIATRIC DENTISTRY, 2015, 37 (02) : 136 - 143
  • [50] An effective method for spreading flowable composites in resin-based restorations
    Abedian, B
    Millstein, P
    OPERATIVE DENTISTRY, 2006, 31 (01) : 151 - 154