Applicability of Glass Dosimeters for In-vivo Dosimetry in Brachytherapy

被引:2
作者
Moon, Sun Young [1 ]
Son, Jaeman [1 ]
Yoon, Myonggeun [1 ]
Jeang, EunHee [2 ]
Lim, Young Kyung [2 ]
Chung, Weon Kyu [3 ]
Kim, Dong Wook [3 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul 02841, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang 10408, South Korea
[3] Kyung Hee Univ Hosp Gangdong, Dept Radiat Oncol, Seoul 05278, South Korea
基金
新加坡国家研究基金会;
关键词
Brachytherapy; Glass dosimeter; In-vivo dosimetry; Patient dose; DOSE-RATE BRACHYTHERAPY; IR-192 HDR BRACHYTHERAPY; THERMOLUMINESCENCE DOSIMETRY; SCINTILLATION DETECTORS; PROSTATE-CANCER; ROD DETECTOR; VERIFICATION; PHANTOM; ARRAY;
D O I
10.3938/jkps.72.1320
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
During brachytherapy, confirming the dose delivered is very important in order to prevent radiation-associated side effects. Therefore, we aimed to confirm the accuracy of dose delivery near the source by inserting glass dosimeters within the applicator. We created an alternative pelvic phantom with the same shape and internal structures as the usual patient. In addition, we created a tandem for insertion of the glass dosimeters and measured the dose near the source by inserting the glass dosimeters into the tandem and evaluating the accuracy of the dwell position and time through the dose near the source. Errors between the values obtained from the five glass dosimeters and the values from the treatment planning system were -6.27, -2.1, -4.18, 6.31, and -0.39%, respectively. The mean error was 3.85%. This value was acceptable considering that the error of the glass dosimeter itself is approximately 3%. Even though a complement of the applicator and the error calibration is required in order to apply this technique clinically, we believe that radiation accidents and overdoses can be prevented through in-vivo dosimetry using a glass dosimeter for brachytherapy.
引用
收藏
页码:1320 / 1325
页数:6
相关论文
共 28 条
[11]   In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams [J].
Francois, Pascal ;
Boissard, Philippe ;
Berger, Lucie ;
Mazal, Alejandro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (01) :1-10
[12]   Evaluation of linear array MOSFET detectors for in vivo dosimetry to measure rectal dose in HDR brachytherapy [J].
Haughey, Aisling ;
Coalter, George ;
Mugabe, Koki .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) :361-366
[13]   Synthesis and physical characteristics of radiophotoluminescent glass dosimeters [J].
Hsu, Shih-Ming ;
Yang, Hsi-Wen ;
Yeh, Tien-Chi ;
Hsu, Wei-Lin ;
Wu, Chin-Hui ;
Lu, Chin-Chang ;
Chen, Wei-Li ;
Huang, David Y. C. .
RADIATION MEASUREMENTS, 2007, 42 (4-5) :621-624
[14]  
Huang D.Y.C., 2011, Advances in Cancer Therapy
[15]  
Huang DY., 2011, RADIO PHOTOLUMINESCE
[16]   Ruby-based inorganic scintillation detectors for 192Ir brachytherapy [J].
Kertzscher, Gustavo ;
Beddar, Sam .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21) :7744-7764
[17]   Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion [J].
Kertzscher, Gustavo ;
Andersen, Claus E. ;
Siebert, Frank-Andre ;
Nielsen, Soren Kynde ;
Lindegaard, Jacob C. ;
Tanderup, Kari .
RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) :456-462
[18]   A plastic scintillation dosimeter for high dose rate brachytherapy [J].
Lambert, J. ;
McKenzie, D. R. ;
Law, S. ;
Elsey, J. ;
Suchowerska, N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21) :5505-5516
[19]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[20]   A TRANSIT DOSE TECHNIQUE FOR THE DETERMINATION OF DOSES IN INHOMOGENEOUS BODIES [J].
OCONNOR, JE .
BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (348) :663-667