Experimental study on the flame extension and risk analysis of a diffusion impinging flame in confined compartment

被引:5
作者
Wang, Aijuan [1 ]
Manescau, Brady [1 ]
Chetehouna, Khaled [1 ]
Rudz, Steve [2 ]
Lamoot, Ludovic [1 ]
机构
[1] Univ Orleans, INSA Ctr Val Loire, PRISME, EA 4229, 88 Blvd Lahitolle, F-18000 Bourges, France
[2] Univ Orleans, CNRS, UMR 7344, GREMI, Bourges, France
关键词
Impinging flame; flame extension; confined compartment; equivalence ratio; auto-ignition; CEILING JETS; FIRE DETECTION; LENGTHS; WALL; GAS;
D O I
10.1177/07349041211015766
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, an experimental investigation on a diffusion impinging flame in a confined compartment was performed. The objective was to study the influence of confinement on the behavior of a flame impinging the ceiling and to deduce the auto-ignition risk of the smoke produced in the confined compartment. For this, configurations with five confinement levels were constructed by the condition of windows and/or door in the compartment and the variation of the heat release rates was made between 0.5 and 18.6 kW. To evaluate the flame morphology and flame extension length, an image processing method based on the direct linear transformation algorithm and the fire segmentation algorithm was adopted. From the experimental data, it was shown that the heat release rate of 4.6 kW presents a critical value for the flame extension in confined configurations, which corresponds to the equivalence ratio of the enclosure greater than 1, highlighting an under-ventilated environment. In addition, an auto-ignition risk analysis of smoke with unburnt gas in the compartment was carried out. The concentration and temperature of these gases were compared to the lower flammability limits and the auto-ignition temperature. It was observed that there was auto-ignition risk of the smoke under the ceiling, especially in the confined compartment of equivalence ratio greater than 1. Under these conditions, it is possible to have a fire spread to another compartment.
引用
收藏
页码:285 / 308
页数:24
相关论文
共 50 条
[31]   Evaluating the combustion and flame extension characteristics of cable fire in utility tunnels with spontaneous combustion scenarios: An experimental study [J].
Xu, Desheng ;
Li, Yanfeng ;
Li, Jiaxin ;
Zhong, Hua ;
Li, Junmei ;
Tu, Dengkai ;
Huang, Youbo .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 140
[32]   Experimental and numerical study on the occurrence of off-stagnation peak in heat flux for laminar methane/air flame impinging on a flat surface [J].
Chander, Subhash ;
Ray, Anjan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (5-6) :1179-1186
[33]   Experimental characterization and numerical simulation of a sooting lifted turbulent jet diffusion flame [J].
Koehler, Markus ;
Geigle, Klaus-Peter ;
Blacha, Thomas ;
Gerlinger, Peter ;
Meier, Wolfgang .
COMBUSTION AND FLAME, 2012, 159 (08) :2620-2635
[34]   Experimental Study of the Effect of Opening Factor on Self-Extinguishing and Blue Ghosting Flame in Under-Ventilated Compartment Fire [J].
Wang, Dong ;
Ju, Xiaoyu ;
Zhou, Xiaodong ;
Zhou, Zhizuan ;
Liu, Hong ;
Zhang, Ping ;
Yang, Lizhong .
FIRE TECHNOLOGY, 2023, 59 (02) :595-621
[35]   Experimental and machine learning studies of thermal impinging flow under ceiling induced by hydrogen-blended methane jet fire: Temperature distribution and flame extension characteristics [J].
Gu, Mingyan ;
He, Qing ;
Tang, Fei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 215
[36]   Experimental investigation of heat transfer characteristics of impinging flame jet with in-house designed heat flux sensor [J].
Amin, Ahmed M. ;
Elaskary, Ahmed H. .
APPLIED THERMAL ENGINEERING, 2025, 268
[37]   An experimental study of the flame propagation and combustion characteristics of LPG fuel [J].
Lee, K ;
Ryu, J .
FUEL, 2005, 84 (09) :1116-1127
[38]   A COMPARATIVE STUDY OF THE KINETICS OF ETHYL AND METHYL ESTERS IN DIFFUSION FLAME EXTINCTION [J].
Dievart, Pascal ;
Gong, Jing ;
Ju, Yiguang .
PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 2, 2014,
[39]   Flame morphologic characteristics of horizontally oriented jet fires impinging on a vertical plate: Experiments and theoretical analysis [J].
Wang, Zhenhua ;
Jiang, Juncheng ;
Wang, Guanghu ;
Ni, Lei ;
Pan, Yong ;
Li, Meng .
ENERGY, 2023, 264
[40]   Experimental Study of the Flame Structural Characteristics and Self-Similar Propagation of Syngas and Air Turbulent Expanding Premixed Flame [J].
Zhang, Guo-Peng ;
Li, Guo-Xiu ;
Li, Hong-Meng ;
Lv, Jia-Cheng .
JOURNAL OF ENERGY ENGINEERING, 2021, 147 (02)