On using experimentally estimated wall shear stresses to validate numerically predicted results

被引:17
作者
Walsh, M [1 ]
McGloughlin, T
Liepsch, DW
O'Brien, T
Morris, L
Ansari, AR
机构
[1] Univ Limerick, Dept Mech & Aeronaut Engn, Biomed Engn Res Ctr, Limerick, Ireland
[2] Univ Limerick, Dept Math & Stat, Limerick, Ireland
[3] Fachochsch Munchen, Lab Fluid Mech, Munich, Germany
关键词
wall shear stress; computational fluid dynamics; laser Doppler anemometry; curve-fitting;
D O I
10.1243/09544110360579286
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this investigation was to assess the use of experimentally estimated wall shear stresses to validate numerically predicted results. The most commonly cited haemodynamic factor implicated in the disease initiation and proliferation processes at graft/artery junctions is wall shear stress (WSS). WSS can be determined from the product of the viscosity of the fluid and the wall shear rate. Numerically, the wall shear rate is predicted using velocity values stored in the computational cell near the wall and assuming zero velocity at the wall. Experimentally, the wall shear rate is estimated by applying a curve-fit to near-wall velocity measurements and evaluating the shear rate at a specific distance from the wall. When estimating the wall shear rate from the laser Doppler anemometry (LDA) point velocity measurements, large differences between the experimentally estimated and numerically predicted WSSs were introduced. It was found that the estimated WSS distributions from the experimental results are highly dependent on the curve-fitting method used to calculate the wall shear rate. However, the velocity profiles for both the experimental and numerical investigations show extremely good comparison. It is concluded that numerical models should be validated using unprocessed LDA point velocity measurement and not estimated WSS values.
引用
收藏
页码:77 / 90
页数:14
相关论文
共 13 条
[1]  
CHO YI, 1991, BIORHEOLOGY, V28, P241
[2]  
Ethier CR, 1998, J BIOMECH, V31, P609, DOI 10.1016/S0021-9290(98)00059-1
[3]   DERIVATION OF SHEER RATES FROM NEAR-WALL LDA MEASUREMENTS UNDER STEADY AND PULSATILE FLOW CONDITIONS [J].
FATEMI, RS ;
RITTGERS, SE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03) :361-368
[4]  
FRASER SM, 1994, OPTICAL DIAGNOSTICS
[5]   Hemodynamic simulations and computer aided designs of graft-artery junctions [J].
Lei, M ;
Kleinstreuer, C ;
Archie, JP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (03) :343-348
[6]  
Liepsch D, 1998, CLIN HEMORHEOL MICRO, V18, P1
[7]  
LOTH F, 1994, ADV BIOENG, V28, P307
[8]  
OHJA M, 1994, EUR J VASC ENDOVASC, V19, P1067
[9]   PULSATILE NON-NEWTONIAN FLOW CHARACTERISTICS IN A 3-DIMENSIONAL HUMAN CAROTID BIFURCATION MODEL [J].
PERKTOLD, K ;
RESCH, M ;
FLORIAN, H .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (04) :464-475
[10]  
VEERSTAG HK, 1995, INTRO COMPUTATIONAL